Literature DB >> 30083944

Predictors of permanent pacemaker implantation after transcatheter aortic valve implantation for aortic stenosis using Medtronic new generation self-expanding CoreValve Evolut R.

Hidehiro Kaneko1, Frank Hoelschermann1, Martin Seifert1, Grit Tambor1, Maki Okamoto1, Viviane Moeller1, Michael Neuss1, Christian Butter2.   

Abstract

Conduction disturbance requiring permanent pacemaker (PPM) implantation is a common complication after transcatheter aortic valve implantation (TAVI) using Medtronic self-expanding CoreValve, and has remained common following the introduction of the new generation CoreValve Evolut R device. The aim of this study was to identify the determinants of PPM implantation after TAVI with CoreValve Evolut R. We retrospectively examined 114 patients who underwent transfemoral TAVI using CoreValve Evolut R. We excluded 17 patients with preprocedural PPM, 1 patient requiring Edwards SAPIEN 3 implantation after CoreValve Evolut R implantation, and 4 patients who died during the hospital admission. Thus, 92 patients were finally included in the analysis. Seventeen patients (18%) underwent new PPM implantation after TAVI. Preprocedural electrocardiography showed a lower ventricular rate and more right bundle branch block (RBBB) in patients with new PPM implantation compared to those without. Quantitative multidetector computed tomography assessment revealed larger aortic valve calcification (AVC) and higher asymmetry (∆AVC) in patients with new PPM implantation compared to those without. The univariate logistic regression analysis demonstrated that preprocedural ventricular rate ≤ 70 beats per minute, RBBB, AVC ≥ 110 mm3, and ∆AVC ≥ 45 mm3 were associated with new PPM implantation. Number of these factors clearly stratified the risk of new PPM implantation. In conclusion, PPM implantation occurs in 18% of patients undergoing TAVI with the new generation CoreValve Evolut R. Lower preprocedural ventricular rate, RBBB, larger AVC, and higher ∆AVC are associated with new PPM implantation after TAVI using the new generation CoreValve Evolut R.

Entities:  

Keywords:  Aortic valve calcification; Permanent pacemaker implantation; Right bundle branch block; Self-expanding CoreValve Evolut R; Transcatheter aortic valve implantation

Mesh:

Year:  2018        PMID: 30083944     DOI: 10.1007/s00380-018-1236-z

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  30 in total

1.  Comparison of aortic root anatomy and calcification distribution between Asian and Caucasian patients who underwent transcatheter aortic valve implantation.

Authors:  Sung-Han Yoon; Yohei Ohno; Motoharu Araki; Marco Barbanti; Mao-Shin Lin; Jung-Min Ahn; Dong Hyun Yang; Young-Hak Kim; Sebastiano Immé; Simona Gulino; Claudia I Tamburino; Carmelo Sgroi; Duk-Woo Park; Soo-Jin Kang; Seung-Whan Lee; Cheol Whan Lee; Seong-Wook Park; Toshiya Muramatsu; Hsien-Li Kao; Corrado Tamburino; Seung-Jung Park
Journal:  Am J Cardiol       Date:  2015-08-31       Impact factor: 2.778

2.  Electrocardiographic and further predictors for permanent pacemaker requirement after transcatheter aortic valve implantation.

Authors:  Damir Erkapic; Won K Kim; Michael Weber; Helge Möllmann; Alexander Berkowitsch; Sergey Zaltsberg; Dmitri J Pajitnev; Johannes Rixe; Thomas Neumann; Malte Kuniss; Johannes Sperzel; Christian W Hamm; Heinz F Pitschner
Journal:  Europace       Date:  2010-03-30       Impact factor: 5.214

3.  Transcatheter aortic valve replacement in nonagenarians: early and intermediate outcome from the OBSERVANT study and meta-analysis of the literature.

Authors:  Fausto Biancari; Paola D'Errigo; Stefano Rosato; Marek Pol; Corrado Tamburino; Marco Ranucci; Fulvia Seccareccia
Journal:  Heart Vessels       Date:  2016-06-01       Impact factor: 2.037

4.  Transcatheter aortic valve implantation in patients on corticosteroid therapy.

Authors:  Ryosuke Higuchi; Tetsuya Tobaru; Kenichi Hagiya; Mike Saji; Keitaro Mahara; Itaru Takamisawa; Jun Shimizu; Shuichiro Takanashi; Morimasa Takayama
Journal:  Heart Vessels       Date:  2017-05-23       Impact factor: 2.037

5.  Improvements of Procedural Results With a New-Generation Self-Expanding Transfemoral Aortic Valve Prosthesis in Comparison to the Old-Generation Device.

Authors:  Bruna Gomes; Nicolas A Geis; Emmanuel Chorianopoulos; Benjamin Meder; Florian Leuschner; Hugo A Katus; Raffi Bekeredjian
Journal:  J Interv Cardiol       Date:  2016-11-24       Impact factor: 2.279

6.  A revised methodology for aortic-valvar complex calcium quantification for transcatheter aortic valve implantation.

Authors:  Hasan Jilaihawi; Raj R Makkar; Mohammad Kashif; Kazuaki Okuyama; Tarun Chakravarty; Takahiro Shiota; Gerald Friede; Mamoo Nakamura; Niraj Doctor; Asim Rafique; Kentaro Shibayama; Hirotsugu Mihara; Alfredo Trento; Wen Cheng; John Friedman; Daniel Berman; Gregory P Fontana
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2014-09-03       Impact factor: 6.875

7.  Predictors of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation for Aortic Stenosis Using New-Generation Balloon-Expandable SAPIEN 3.

Authors:  Hidehiro Kaneko; Frank Hoelschermann; Grit Tambor; Sung-Han Yoon; Michael Neuss; Christian Butter
Journal:  Am J Cardiol       Date:  2016-11-16       Impact factor: 2.778

8.  Comparison of the Edwards SAPIEN S3 Versus Medtronic Evolut-R Devices for Transcatheter Aortic Valve Implantation.

Authors:  Jeremy Ben-Shoshan; Maayan Konigstein; David Zahler; Gilad Margolis; Ehud Chorin; Arie Steinvil; Yaron Arbel; Galit Aviram; Yoav Granot; Michael Barkagan; Gad Keren; Amir Halkin; Shmuel Banai; Ariel Finkelstein
Journal:  Am J Cardiol       Date:  2016-10-07       Impact factor: 2.778

9.  Cost of transcatheter aortic valve implantation and factors associated with higher hospital stay cost in patients of the FRANCE (FRench Aortic National CoreValve and Edwards) registry.

Authors:  Karine Chevreul; Matthias Brunn; Benjamin Cadier; Georges Haour; Hélène Eltchaninoff; Alain Prat; Alain Leguerrier; Didier Blanchard; Gérard Fournial; Bernard Iung; Patrick Donzeau-Gouge; Christophe Tribouilloy; Jean-Louis Debrux; Alain Pavie; Martine Gilard; Pascal Gueret
Journal:  Arch Cardiovasc Dis       Date:  2013-04-24       Impact factor: 2.340

10.  Assessment of atrioventricular conduction in aortic valve disease.

Authors:  H S Friedman; Q Zaman; J I Haft; S Melendez
Journal:  Br Heart J       Date:  1978-08
View more
  1 in total

Review 1.  Should All Low-risk Patients Now Be Considered for TAVR? Operative Risk, Clinical, and Anatomic Considerations.

Authors:  Saima Siddique; Hemal Gada; Mubashir A Mumtaz; Amit N Vora
Journal:  Curr Cardiol Rep       Date:  2019-11-28       Impact factor: 2.931

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.