Literature DB >> 25187618

A revised methodology for aortic-valvar complex calcium quantification for transcatheter aortic valve implantation.

Hasan Jilaihawi1, Raj R Makkar2, Mohammad Kashif2, Kazuaki Okuyama2, Tarun Chakravarty2, Takahiro Shiota2, Gerald Friede2, Mamoo Nakamura2, Niraj Doctor2, Asim Rafique2, Kentaro Shibayama2, Hirotsugu Mihara2, Alfredo Trento2, Wen Cheng2, John Friedman2, Daniel Berman2, Gregory P Fontana3.   

Abstract

AIMS: We sought to optimize a method for quantification of the calcium in the aortic-valvar complex for the prediction of significant paravalvular leak (PVL) after transcatheter aortic valve implantation (TAVI). METHODS AND
RESULTS: All patients had severe symptomatic aortic stenosis and were treated with balloon-expandable TAVI (Sapien/Sapien-XT, Edwards Lifesciences LLC, Irvine, CA, USA). In order to correct for precise annular sizing, only patients with available contrast computed tomography (CT) data for measurements were included (n = 198). Paravalvular leak was quantified using peri-procedural transoesophageal echocardiography by Valve Academic Research Consortium-2 (VARC-2) criteria (grade ≥ moderate was considered significant). A detailed region-of-interest methodology separated quantification of calcium in each of the aortic leaflets to that in the left ventricular outflow tract (LVOT) and was used to predict PVL in receiver operator characteristic curve analyses. For non-contrast scans, the greatest discriminatory value for PVL was seen at the 450 Hounsfield Unit (HU) threshold for detection (volume ≥626 mm(3)), whereas for contrast scans it was at 850 HU (≥235 mm(3)). Left ventricular outflow tract calcium predicted PVL but only as a binary variable with no incremental value of quantification. In a multivariable binary logistic regression model, annulus area ≥ prosthesis area (OR 3.5, 95% CI 1.5-8.2, P = 0.005), contrast leaflet calcium volume (850-HU threshold) ≥235 mm(3) (OR 2.8, 95% CI 1.2-6.7, P = 0.023), and presence of LVOT calcium (OR 2.8, 95% CI 1.2-7.0, P = 0.022) were independent predictors for PVL ≥ moderate.
CONCLUSION: Both leaflet and LVOT calcium are significant predictors of PVL and exert an important synergistic influence on this complication, even in appropriately sized valves. With careful attention to thresholds for detection, clinically relevant leaflet calcium volumes can be identified with either non-contrast or contrast CT scans. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2014. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  Calcification; Calcium score; TAVI; TAVR; Transcatheter aortic valve

Mesh:

Substances:

Year:  2014        PMID: 25187618     DOI: 10.1093/ehjci/jeu162

Source DB:  PubMed          Journal:  Eur Heart J Cardiovasc Imaging        ISSN: 2047-2404            Impact factor:   6.875


  21 in total

Review 1.  CT support of cardiac structural interventions.

Authors:  Michaela M Hell; Stephan Achenbach
Journal:  Br J Radiol       Date:  2019-03-11       Impact factor: 3.039

2.  Comparison of outcomes using balloon-expandable versus self-expanding transcatheter prostheses according to the extent of aortic valve calcification.

Authors:  Won-Keun Kim; Johannes Blumenstein; Christoph Liebetrau; Andreas Rolf; Luise Gaede; Arnaud Van Linden; Mani Arsalan; Mirko Doss; Jan G P Tijssen; Christian W Hamm; Thomas Walther; Helge Möllmann
Journal:  Clin Res Cardiol       Date:  2017-08-09       Impact factor: 5.460

3.  Impact of valvular resistance on aortic regurgitation after transcatheter aortic valve replacement according to the type of prosthesis.

Authors:  Masahiko Asami; Thomas Pilgrim; Stefan Stortecky; Dik Heg; Eva Roost; Stephan Windecker; Lukas Hunziker
Journal:  Clin Res Cardiol       Date:  2019-03-30       Impact factor: 5.460

4.  Modern Use of Echocardiography in Transcatheter Aortic Valve Replacement: an Up-Date.

Authors:  Cristina Caldararu; Serban Balanescu
Journal:  Maedica (Bucur)       Date:  2016-12

5.  Predictors for permanent pacemaker implantation in patients undergoing transfemoral aortic valve implantation with the Edwards Sapien 3 valve.

Authors:  Birgid Gonska; Julia Seeger; Mirjam Keßler; Alexander von Keil; Wolfgang Rottbauer; Jochen Wöhrle
Journal:  Clin Res Cardiol       Date:  2017-03-10       Impact factor: 5.460

6.  Impact of aortic valve calcification severity on device success after transcatheter aortic valve replacement.

Authors:  Jeremy Larroche; Loïc Panh; Thibault Lhermusier; Vincent Bataille; Marie-Agnès Marachet; Thomas Chollet; Antoine Petermann; Frederic Bouisset; Nicolas Boudou; Bertrand Marcheix; Hervé Rousseau; Michel Galinier; Didier Carrié; Olivier Lairez; Yoan Lavie-Badie
Journal:  Int J Cardiovasc Imaging       Date:  2020-01-08       Impact factor: 2.357

Review 7.  The Crucial Role of Cardiac Imaging in Transcatheter Aortic Valve Replacement (TAVR): Pre- and Post-procedural Assessment.

Authors:  Saif Al-Najafi; Frank Sanchez; Stamatios Lerakis
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-12

8.  Computed Tomography for Structural Heart Disease and Interventions.

Authors:  Pascal Thériault-Lauzier; Marco Spaziano; Beatriz Vaquerizo; Jean Buithieu; Giuseppe Martucci; Nicolo Piazza
Journal:  Interv Cardiol       Date:  2015-09

9.  Predictors of permanent pacemaker implantation after transcatheter aortic valve implantation for aortic stenosis using Medtronic new generation self-expanding CoreValve Evolut R.

Authors:  Hidehiro Kaneko; Frank Hoelschermann; Martin Seifert; Grit Tambor; Maki Okamoto; Viviane Moeller; Michael Neuss; Christian Butter
Journal:  Heart Vessels       Date:  2018-08-06       Impact factor: 2.037

10.  New insights on potential permanent pacemaker predictors in TAVR using the largest self-expandable device.

Authors:  Verena Veulemans; Derk Frank; Hatim Seoudy; Steffen Wundram; Kerstin Piayda; Oliver Maier; Christian Jung; Amin Polzin; Norbert Frey; Malte Kelm; Tobias Zeus
Journal:  Cardiovasc Diagn Ther       Date:  2020-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.