Predictors of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation for Aortic Stenosis Using New-Generation Balloon-Expandable SAPIEN 3.

Hidehiro Kaneko1, Frank Hoelschermann1, Grit Tambor1, Sung-Han Yoon2, Michael Neuss1, Christian Butter3.   

Abstract

Paravalvular regurgitation (PVR) is a common and serious complication after transcatheter aortic valve implantation (TAVI). New-generation balloon-expandable SAPIEN 3 has an outer sealing skirt to minimize PVR. However, the predictors of PVR after SAPIEN 3 transcatheter heart valve (THV) implantation have not been well investigated. We sought to clarify the determinants of PVR after TAVI using SAPIEN 3 with quantitative multidetector computed tomography (MDCT) assessment. This study analyzed 281 patients with severe symptomatic aortic stenosis who underwent TAVI using SAPIEN 3. Quantitative assessment of aortic root dimensions and calcium volume for leaflet, annulus, and left ventricular outflow tract were retrospectively performed with MDCT. MDCT nominal area oversizing was calculated using the following formula: % oversizing = (THV nominal area/MDCT derived annular area - 1) × 100. Logistic regression analysis was performed to determine the predictors of PVR greater than or equal to mild. PVR greater than or equal to mild was observed in 19% (53 of 281). Quantity and asymmetry of aortic valve calcium of annulus, left ventricular outflow tract, and leaflet were associated with higher incidence of PVR greater than or equal to mild, except leaflet asymmetry. Lower percentage of THV oversizing was also associated with PVR. Multivariable logistic regression analysis showed that larger calcification volume of annulus and lower percentage of THV oversizing were independent predictors of PVR greater than or equal to mild. These results suggest that prosthesis/annulus incongruence and aortic annulus calcification predicted PVR greater than or equal to mild after TAVI using SAPIEN 3.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 28010874     DOI: 10.1016/j.amjcard.2016.10.047

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  1 in total

1.  Predictors of permanent pacemaker implantation after transcatheter aortic valve implantation for aortic stenosis using Medtronic new generation self-expanding CoreValve Evolut R.

Authors:  Hidehiro Kaneko; Frank Hoelschermann; Martin Seifert; Grit Tambor; Maki Okamoto; Viviane Moeller; Michael Neuss; Christian Butter
Journal:  Heart Vessels       Date:  2018-08-06       Impact factor: 2.037

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.