Literature DB >> 21948547

Anterior chamber angle imaging with swept-source optical coherence tomography: an investigation on variability of angle measurement.

Shu Liu1, Marco Yu, Cong Ye, Dennis S C Lam, Christopher Kai-Shun Leung.   

Abstract

PURPOSE: To evaluate the reproducibility of anterior chamber angle measurements obtained by swept-source optical coherence tomography (OCT) and to identify factors associated with its measurement variability.
METHODS: One eye from each of 30 healthy subjects was randomly selected for anterior segment OCT imaging (Casia SS-1000 OCT; Tomey, Nagoya, Japan) in three separate visits within a week. The angle opening distance (AOD), the trabecular iris space area (TISA), and the trabecular-iris angle (TIA) at the superior (90°), nasal (0°), inferior (270°), and temporal (180°) angles were measured. The intraobserver and interobserver reproducibility coefficient (RC) and intraclass correlation coefficient (ICC) were calculated. Generalized linear latent and mixed modeling was used to examine the association between the variance of angle measurements and each of the following: angle width, pupil diameter, pupil diameter variance, iris thickness, iris thickness variance, axial length, anterior chamber depth, scan location, scleral spur visibility, and age.
RESULTS: The intervisit, intraobserver RCs ranged between 0.140 mm and 0.252 mm for AOD, 0.050 mm(2) and 0.090 mm(2) for TISA, and 7.7° and 9.5° for TIA, and the interobserver RCs were between 0.103 mm and 0.187 mm, 0.049 mm(2) and 0.101 mm(2), and 8.5° and 13.7°, respectively. The ICCs were all ≥0.83. Increased iris thickness, increased iris thickness variance, angle measured at the superior and inferior quadrants, increased angle width, and long axial length were associated with increased variance of angle measurements.
CONCLUSIONS: Although the swept-source OCT had high reproducibility for angle measurement, differences in iris thickness, angle width, measurement location, and axial length may influence its variability.

Mesh:

Year:  2011        PMID: 21948547     DOI: 10.1167/iovs.11-7507

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  32 in total

1.  Comparing Gonioscopy With Visante and Cirrus Optical Coherence Tomography for Anterior Chamber Angle Assessment in Glaucoma Patients.

Authors:  Mallika K Doss; Lauren S Blieden; David A Lee; Nicholas P Bell; Robert M Feldman
Journal:  J Glaucoma       Date:  2017-03       Impact factor: 2.503

2.  Optimal number of angle images for calculating anterior angle volume and iris volume measurements.

Authors:  Lauren S Blieden; Alice Z Chuang; Laura A Baker; Nicholas P Bell; Timothy S Fuller; Kimberly A Mankiewicz; Robert M Feldman
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-05       Impact factor: 4.799

3.  Association between baseline angle width and induced angle opening following prophylactic laser peripheral iridotomy.

Authors:  Roland Y Lee; Toshimitsu Kasuga; Qi N Cui; Guofu Huang; Mingguang He; Shan C Lin
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-05-01       Impact factor: 4.799

4.  Sectoral variations of iridocorneal angle width and iris volume in Chinese Singaporeans: a swept-source optical coherence tomography study.

Authors:  Tin A Tun; Mani Baskaran; Shamira A Perera; Anita S Chan; Ching-Yu Cheng; Hla M Htoon; Lisandro M Sakata; Carol Y Cheung; Tin Aung
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-04-30       Impact factor: 3.117

5.  Deep Learning Classifiers for Automated Detection of Gonioscopic Angle Closure Based on Anterior Segment OCT Images.

Authors:  Benjamin Y Xu; Michael Chiang; Shreyasi Chaudhary; Shraddha Kulkarni; Anmol A Pardeshi; Rohit Varma
Journal:  Am J Ophthalmol       Date:  2019-08-22       Impact factor: 5.258

6.  Evaluation of anterior chamber parameters with spectral-domain optical coherence tomography.

Authors:  Isabel Pinilla Lozano; Carmen López de la Fuente; Francisco Segura; Elvira Orduna Hospital; Ana Sánchez-Cano
Journal:  Jpn J Ophthalmol       Date:  2017-11-29       Impact factor: 2.447

7.  Repeatability and agreement of two anterior segment OCT in myopic patients before implantable collamer lenses implantation.

Authors:  Xi-Fang Zhang; Meng Li; Yan Shi; Xiu-Hua Wan; Huai-Zhou Wang
Journal:  Int J Ophthalmol       Date:  2020-04-18       Impact factor: 1.779

8.  Ciliary muscle morphology and accommodative lag in hyperopic anisometropic children.

Authors:  Jinglin Shi; Jing Zhao; Feng Zhao; Rajeev Naidu; Xingtao Zhou
Journal:  Int Ophthalmol       Date:  2020-01-08       Impact factor: 2.031

9.  Low iris and anterior chamber volume is associated with deepening after laser peripheral iridotomy in primary angle closure suspects.

Authors:  Hamed Esfandiari; Mohammad Pakravan; Nassim Amouhashemi; Mehdi Yaseri; Pooya Torkian; Khosrow Jadidi; Nils A Loewen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-08-02       Impact factor: 3.117

10.  Swept source optical coherence tomography measurement of the iris-trabecular contact (ITC) index: a new parameter for angle closure.

Authors:  Sue-Wei Ho; Mani Baskaran; Ce Zheng; Tin A Tun; Shamira A Perera; Arun K Narayanaswamy; David S Friedman; Tin Aung
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-09-23       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.