Iris Yuwen Zhou1, Dongshuang Lu1, Yang Ji1, Limin Wu2, Enfeng Wang3, Jerry S Cheung1, Xiao-An Zhang3, Phillip Zhe Sun1,4,5. 1. Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts. 2. Neuroscience Center and Department of Pediatrics, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts. 3. Department of Radiology, Third Affiliated Hospital, Zhengzhou University, Henan, China. 4. Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, Georgia. 5. Department of Radiology, Emory University School of Medicine, Atlanta, Georgia.
Abstract
PURPOSE: Chemical exchange saturation transfer (CEST) MRI has been used for quantitative assessment of dilute metabolites and/or pH in disorders such as acute stroke and tumor. However, routine asymmetry analysis (MTRasym ) may be confounded by concomitant effects such as semisolid macromolecular magnetization transfer (MT) and nuclear Overhauser enhancement. Resolving multiple contributions is essential for elucidating the origins of in vivo CEST contrast. METHODS: Here we used a newly proposed image downsampling expedited adaptive least-squares fitting on densely sampled Z-spectrum to quantify multipool contribution from water, nuclear Overhauser enhancement, MT, guanidinium, amine, and amide protons in adult male Wistar rats before and after global ischemia. RESULTS: Our results revealed the major contributors to in vivo T1 -normalized MTRasym (3.5 ppm) contrast between white and gray matter (WM/GM) in normal brain (-1.96%/second) are pH-insensitive macromolecular MT (-0.89%/second) and nuclear Overhauser enhancement (-1.04%/second). Additionally, global ischemia resulted in significant changes of MTRasym , being -2.05%/second and -1.56%/second in WM and GM, which are dominated by changes in amide (-1.05%/second, -1.14%/second) and MT (-0.88%/second, -0.62%/second). Notably, the pH-sensitive amine and amide effects account for nearly 60% and 80% of the MTRasym changes seen in WM and GM, respectively, after global ischemia, indicating that MTRasym is predominantly pH-sensitive. CONCLUSION: Combined amide and amine effects dominated the MTRasym changes after global ischemia, indicating that MTRasym is predominantly pH-sensitive and suitable for detecting tissue acidosis following acute stroke.
PURPOSE: Chemical exchange saturation transfer (CEST) MRI has been used for quantitative assessment of dilute metabolites and/or pH in disorders such as acute stroke and tumor. However, routine asymmetry analysis (MTRasym ) may be confounded by concomitant effects such as semisolid macromolecular magnetization transfer (MT) and nuclear Overhauser enhancement. Resolving multiple contributions is essential for elucidating the origins of in vivo CEST contrast. METHODS: Here we used a newly proposed image downsampling expedited adaptive least-squares fitting on densely sampled Z-spectrum to quantify multipool contribution from water, nuclear Overhauser enhancement, MT, guanidinium, amine, and amide protons in adult male Wistar rats before and after global ischemia. RESULTS: Our results revealed the major contributors to in vivo T1 -normalized MTRasym (3.5 ppm) contrast between white and gray matter (WM/GM) in normal brain (-1.96%/second) are pH-insensitive macromolecular MT (-0.89%/second) and nuclear Overhauser enhancement (-1.04%/second). Additionally, global ischemia resulted in significant changes of MTRasym , being -2.05%/second and -1.56%/second in WM and GM, which are dominated by changes in amide (-1.05%/second, -1.14%/second) and MT (-0.88%/second, -0.62%/second). Notably, the pH-sensitive amine and amide effects account for nearly 60% and 80% of the MTRasym changes seen in WM and GM, respectively, after global ischemia, indicating that MTRasym is predominantly pH-sensitive. CONCLUSION: Combined amide and amine effects dominated the MTRasym changes after global ischemia, indicating that MTRasym is predominantly pH-sensitive and suitable for detecting tissue acidosis following acute stroke.
Authors: Moritz Zaiss; Johannes Windschuh; Daniel Paech; Jan-Eric Meissner; Sina Burth; Benjamin Schmitt; Philip Kickingereder; Benedikt Wiestler; Wolfgang Wick; Martin Bendszus; Heinz-Peter Schlemmer; Mark E Ladd; Peter Bachert; Alexander Radbruch Journal: Neuroimage Date: 2015-02-26 Impact factor: 6.556
Authors: Vipul R Sheth; Yuguo Li; Liu Qi Chen; Christine M Howison; Chris A Flask; Mark D Pagel Journal: Magn Reson Med Date: 2011-10-25 Impact factor: 4.668
Authors: Peter C M van Zijl; Jinyuan Zhou; Noriko Mori; Jean-Francois Payen; David Wilson; Susumu Mori Journal: Magn Reson Med Date: 2003-03 Impact factor: 4.668
Authors: Craig K Jones; Alan Huang; Jiadi Xu; Richard A E Edden; Michael Schär; Jun Hua; Nikita Oskolkov; Domenico Zacà; Jinyuan Zhou; Michael T McMahon; Jay J Pillai; Peter C M van Zijl Journal: Neuroimage Date: 2013-04-06 Impact factor: 6.556
Authors: Moritz Zaiss; Johannes Windschuh; Steffen Goerke; Daniel Paech; Jan-Eric Meissner; Sina Burth; Philipp Kickingereder; Wolfgang Wick; Martin Bendszus; Heinz-Peter Schlemmer; Mark E Ladd; Peter Bachert; Alexander Radbruch Journal: Magn Reson Med Date: 2016-01-27 Impact factor: 4.668
Authors: Lee Sze Foo; George Harston; Amit Mehndiratta; Wun-She Yap; Yan Chai Hum; Khin Wee Lai; Shahizon Azura Mohamed Mukari; Faizah Mohd Zaki; Yee Kai Tee Journal: Quant Imaging Med Surg Date: 2021-08
Authors: Ran Sui; Lin Chen; Yuguo Li; Jianpan Huang; Kannie W Y Chan; Xiang Xu; Peter C M van Zijl; Jiadi Xu Journal: Magn Reson Med Date: 2021-03-27 Impact factor: 3.737