Literature DB >> 26845067

Downfield-NOE-suppressed amide-CEST-MRI at 7 Tesla provides a unique contrast in human glioblastoma.

Moritz Zaiss1, Johannes Windschuh1, Steffen Goerke1, Daniel Paech2,3, Jan-Eric Meissner1,3, Sina Burth2,3, Philipp Kickingereder2, Wolfgang Wick4,5, Martin Bendszus2, Heinz-Peter Schlemmer3, Mark E Ladd1, Peter Bachert1, Alexander Radbruch2,3.   

Abstract

PURPOSE: The chemical exchange saturation transfer (CEST) effect observed in brain tissue in vivo at the frequency offset 3.5 ppm downfield of water was assigned to amide protons of the protein backbone. Obeying a base-catalyzed exchange process such an amide-CEST effect would correlate with intracellular pH and protein concentration, correlations that are highly interesting for cancer diagnosis. However, recent experiments suggested that, besides the known aliphatic relayed-nuclear Overhauser effect (rNOE) upfield of water, an additional downfield rNOE is apparent in vivo resonating as well around +3.5 ppm. In this study, we present further evidence for the underlying downfield-rNOE signal, and we propose a first method that suppresses the downfield-rNOE contribution to the amide-CEST contrast. Thus, an isolated amide-CEST effect depending mainly on amide proton concentration and pH is generated.
METHODS: The isolation of the exchange mediated amide proton effect was investigated in protein model-solutions and tissue lysates and successfully applied to in vivo CEST images of 11 glioblastoma patients.
RESULTS: Comparison with gadolinium contrast enhancing longitudinal relaxation time-weighted images revealed that the downfield-rNOE-suppressed amide-CEST contrast forms a unique contrast that delineates tumor regions and show remarkable overlap with the gadolinium contrast enhancement.
CONCLUSION: Thus, suppression of the downfield rNOE contribution might be the important step to yield the amide proton CEST contrast originally aimed at. Magn Reson Med 77:196-208, 2017.
© 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  7T; AREX; CEST; aliphatic rNOE; aromatic rNOE; brain tumor; glioblastoma; relaxation compensation; relaxation-compensated CEST; spillover correction; ultra-high field

Mesh:

Year:  2016        PMID: 26845067     DOI: 10.1002/mrm.26100

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  45 in total

1.  Improving the detection sensitivity of pH-weighted amide proton transfer MRI in acute stroke patients using extrapolated semisolid magnetization transfer reference signals.

Authors:  Hye-Young Heo; Yi Zhang; Tina M Burton; Shanshan Jiang; Yansong Zhao; Peter C M van Zijl; Richard Leigh; Jinyuan Zhou
Journal:  Magn Reson Med       Date:  2017-06-21       Impact factor: 4.668

2.  Relaxation-compensated amide proton transfer (APT) MRI signal intensity is associated with survival and progression in high-grade glioma patients.

Authors:  Daniel Paech; Constantin Dreher; Sebastian Regnery; Jan-Eric Meissner; Steffen Goerke; Johannes Windschuh; Johanna Oberhollenzer; Miriam Schultheiss; Katerina Deike-Hofmann; Sebastian Bickelhaupt; Alexander Radbruch; Moritz Zaiss; Andreas Unterberg; Wolfgang Wick; Martin Bendszus; Peter Bachert; Mark E Ladd; Heinz-Peter Schlemmer
Journal:  Eur Radiol       Date:  2019-02-26       Impact factor: 5.315

3.  Separating fast and slow exchange transfer and magnetization transfer using off-resonance variable-delay multiple-pulse (VDMP) MRI.

Authors:  Lin Chen; Xiang Xu; Haifeng Zeng; Kannie W Y Chan; Nirbhay Yadav; Shuhui Cai; Kathryn J Schunke; Nauder Faraday; Peter C M van Zijl; Jiadi Xu
Journal:  Magn Reson Med       Date:  2018-02-05       Impact factor: 4.668

4.  Renal pH Imaging Using Chemical Exchange Saturation Transfer (CEST) MRI: Basic Concept.

Authors:  Dario Livio Longo; Pietro Irrera; Lorena Consolino; Phillip Zhe Sun; Michael T McMahon
Journal:  Methods Mol Biol       Date:  2021

5.  Chemical exchange rotation transfer (CERT) on human brain at 3 Tesla.

Authors:  Eugene C Lin; Hua Li; Zhongliang Zu; Elizabeth A Louie; Christopher L Lankford; Richard D Dortch; Mark D Does; John C Gore; Daniel F Gochberg
Journal:  Magn Reson Med       Date:  2018-05-25       Impact factor: 4.668

Review 6.  CEST, ASL, and magnetization transfer contrast: How similar pulse sequences detect different phenomena.

Authors:  Linda Knutsson; Jiadi Xu; André Ahlgren; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2018-05-30       Impact factor: 4.668

7.  CEST imaging of fast exchanging amine pools with corrections for competing effects at 9.4 T.

Authors:  Xiao-Yong Zhang; Feng Wang; Hua Li; Junzhong Xu; Daniel F Gochberg; John C Gore; Zhongliang Zu
Journal:  NMR Biomed       Date:  2017-03-08       Impact factor: 4.044

8.  MRI-CEST assessment of tumour perfusion using X-ray iodinated agents: comparison with a conventional Gd-based agent.

Authors:  Annasofia Anemone; Lorena Consolino; Dario Livio Longo
Journal:  Eur Radiol       Date:  2016-08-29       Impact factor: 5.315

9.  Machine learning improves classification of preclinical models of pancreatic cancer with chemical exchange saturation transfer MRI.

Authors:  Joshua M Goldenberg; Julio Cárdenas-Rodríguez; Mark D Pagel
Journal:  Magn Reson Med       Date:  2018-09-17       Impact factor: 4.668

10.  Quantitative CEST and MT at 1.5T for monitoring treatment response in glioblastoma: early and late tumor progression during chemoradiation.

Authors:  Rachel W Chan; Hanbo Chen; Sten Myrehaug; Eshetu G Atenafu; Greg J Stanisz; James Stewart; Pejman Jabehdar Maralani; Aimee K M Chan; Shadi Daghighi; Mark Ruschin; Sunit Das; James Perry; Gregory J Czarnota; Arjun Sahgal; Angus Z Lau
Journal:  J Neurooncol       Date:  2020-11-16       Impact factor: 4.130

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.