Literature DB >> 30054940

Contrast sensitivity of amblyopic eyes in children with myopic anisometropia.

Yi Pang1, Megan Allen1, Joshua Robinson1, Kelly A Frantz1.   

Abstract

BACKGROUND: Contrast sensitivity function (CSF) in amblyopes has been studied extensively, with few studies on amblyopia associated with myopic anisometropia. The purpose of this study was to investigate CSF of amblyopic eyes in children with myopic anisometropia compared to fellow eyes of the amblyopic children, as well as to control subjects with high myopia but no amblyopia.
METHODS: Twenty amblyopic children with myopic anisometropia (range of visual acuity in the amblyopic eye: 6/10 to 6/100) and 16 control subjects with high myopia (< -6.00 D) but no amblyopia were recruited. CSF with linear sine-wave gratings was assessed at 1.5, 3, 6, 12 and 18 cycles per degree (cpd) in the amblyopic, fellow and control myopic eyes. Multivariate analysis of variance was used to compare logCS of the amblyopic, fellow and control myopic eyes after adjusting for age and race.
RESULTS: The average degree of myopia in the amblyopic eyes was -10.46 D (range: -5.00 to -18.25 D). The average degree of myopia in the right eyes of control subjects was -8.61 D (range: -6.25 to -13 D). A statistically significant difference was found in logCS among the three groups of eyes at all frequencies (p < 0.001) except at 1.5 cpd. CSF of amblyopic eyes was statistically significantly lower than that of control myopic eyes at 3, 6, 12 and 18 cpd but not at 1.5 cpd. No significant difference in logCS was found between control myopic and fellow eyes. The co-variates (age and race) were not significantly related to the logCS (p > 0.05). Reduced CSF of the amblyopic eyes at the middle frequencies was associated with the degree of anisometropia.
CONCLUSION: CSF at the middle and higher frequencies was reduced in the amblyopic eyes associated with myopic anisometropia compared to the fellow eyes of the same amblyopic children as well as to eyes of control subjects with high myopia but no amblyopia.
© 2018 Optometry Australia.

Entities:  

Keywords:  amblyopia; anisometropia; children; contrast sensitivity; myopia

Mesh:

Year:  2018        PMID: 30054940     DOI: 10.1111/cxo.12817

Source DB:  PubMed          Journal:  Clin Exp Optom        ISSN: 0816-4622            Impact factor:   2.742


  7 in total

1.  Comparison of contrast sensitivity based on the surgical results for intermittent exotropia.

Authors:  Hae Rang Kim; Soo Jung Lee
Journal:  Int J Ophthalmol       Date:  2019-11-18       Impact factor: 1.779

2.  Static and Dynamic Pupil Characteristics in Myopic Anisometropic Amblyopia.

Authors:  Hasan Kiziltoprak; Kemal Tekin; Esat Yetkin; Mehmet Ali Sekeroglu
Journal:  Beyoglu Eye J       Date:  2020-07-29

3.  Global Tendency and Frontiers of Research on Myopia From 1900 to 2020: A Bibliometrics Analysis.

Authors:  Mengyuan Shan; Yi Dong; Jingyi Chen; Qing Su; Yan Wan
Journal:  Front Public Health       Date:  2022-03-10

4.  Examination of Macular Retina and Choroidal Thickness in High Myopic Amblyopia Using Spectral-Domain Optical Coherence Tomography.

Authors:  Juan Wan; Zhengwei Zhang; Yu Tian
Journal:  Front Med (Lausanne)       Date:  2022-03-28

5.  Changes in contrast sensitivity after surgery for intermittent exotropia.

Authors:  Young Hwan Bae; Dong Gyu Choi
Journal:  Sci Rep       Date:  2022-04-21       Impact factor: 4.996

6.  Validation of an Automated Early Treatment Diabetic Retinopathy Study Low-contrast Letter Acuity Test.

Authors:  Yi Pang; Lauren Sparschu; Elyse Nylin; Jingyun Wang
Journal:  Optom Vis Sci       Date:  2020-05       Impact factor: 2.106

7.  Factors Affecting Contrast Sensitivity in Intermittent Exotropia.

Authors:  Ji Min Kwon; Soo Jung Lee
Journal:  Korean J Ophthalmol       Date:  2020-10-05
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.