Literature DB >> 24286839

Correlation of nuclear density using the Lens Opacity Classification System III versus Scheimpflug imaging with phacoemulsification parameters.

Monika Gupta1, Jagat Ram, Arun Jain, Jaspreet Sukhija, Manish Chaudhary.   

Abstract

PURPOSE: To grade nuclear cataracts using the Lens Opacity Classification System III (LOCS III) and the correlation with maximum nuclear density on Scheimpflug imaging and phacoemulsification parameters.
SETTING: Tertiary care center.
DESIGN: Longitudinal interventional study.
METHODS: The nuclear density of significant age-related cataracts was evaluated by comparing slitlamp images with standard photographic charts of the LOCS III system. Maximum nuclear density was calculated using a Scheimpflug imaging system (Pentacam). All patients had phacoemulsification and posterior chamber intraocular lens implantation. Intraoperatively, parameters (eg, phaco time, power consumed, balanced salt solution used) were noted and compared with different grades of cataract and maximum nuclear densities.
RESULTS: One hundred patients with visually significant age-related cataract were evaluated. There was a positive linear correlation between the LOCS III grading and Scheimpflug maximum nuclear density (P<.001). The LOCS III grading and Scheimpflug maximum nuclear density had a linear correlation with preoperative corrected distance visual acuity (r = 0.588 and r = 0.525, respectively), cumulative dissipated energy (CDE) (r = 0.607 and r = 0.847, respectively), total ultrasound (US) time (r = 0.627 and r = 0.802, respectively), and fluid used (r = 0.623 and r = 0.678, respectively).
CONCLUSION: Both systems had a linear correlation with total US power, CDE, and fluid used; however, the Scheimpflug imaging system had a stronger correlation with these phacoemulsification parameters.
Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 24286839     DOI: 10.1016/j.jcrs.2013.05.052

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  18 in total

1.  Comparison of objective and subjective refractive surgery screening parameters between regular and high-resolution Scheimpflug imaging devices.

Authors:  J Bradley Randleman; Jihan Akhtar; Michael J Lynn; Renato Ambrósio; William J Dupps; Ronald R Krueger; Stephen D Klyce
Journal:  J Cataract Refract Surg       Date:  2014-12-20       Impact factor: 3.351

2.  Correlation between different Scheimpflug-based lens densitometry analysis and effective phacoemulsification time in mild nuclear cataracts.

Authors:  Fernando Faria-Correia; Bernardo Lopes; Tiago Monteiro; Nuno Franqueira; Renato Ambrósio
Journal:  Int Ophthalmol       Date:  2017-05-26       Impact factor: 2.031

3.  Comparing surgical efficiencies between phacoemulsification systems: a single surgeon retrospective study of 2000 eyes.

Authors:  Luis Escaf-Jaraba; Jorge Escobar-DiazGranados; Bartolomé Valdemarín
Journal:  Int J Ophthalmol       Date:  2022-04-18       Impact factor: 1.779

4.  Comparison of 25 MHz and 50 MHz ultrasound biomicroscopy for imaging of the lens and its related diseases.

Authors:  Ming-Yu Shi; Xiao Han; Jin-Song Zhang; Qi-Chang Yan
Journal:  Int J Ophthalmol       Date:  2018-07-18       Impact factor: 1.779

5.  Objective quantification of lens nuclear opacities using swept-source anterior segment optical coherence tomography.

Authors:  Wei Wang; Jiaqing Zhang; Xiaoxun Gu; Xiaoting Ruan; Xiaoyun Chen; Xuhua Tan; Guangming Jin; Lanhua Wang; Mingguang He; Nathan Congdon; Zhenzhen Liu; Lixia Luo; Yizhi Liu
Journal:  Br J Ophthalmol       Date:  2021-01-13       Impact factor: 5.908

6.  Determinants of Visual Outcomes in Femtosecond Laser Assisted Cataract Surgery and Phacoemulsification: A Nested Case Control Study.

Authors:  Rajiv Khandekar; Ashley Behrens; Abdul Elah Al Towerki; William May; Saeed Motowa; Komal Tailor; Ches Souru
Journal:  Middle East Afr J Ophthalmol       Date:  2015 Jul-Sep

7.  Objective Assessment of Nuclear and Cortical Cataracts through Scheimpflug Images: Agreement with the LOCS III Scale.

Authors:  Alberto Domínguez-Vicent; Ulrika Birkeldh; Carl-Gustaf Laurell; Laurell Carl-Gustaf; Maria Nilson; Rune Brautaset
Journal:  PLoS One       Date:  2016-02-18       Impact factor: 3.240

8.  Evaluation of a 345 nm Femtosecond Laser for Corneal Surgery with Respect to Intraocular Radiation Hazard.

Authors:  Johannes Menzel-Severing; Corinna Petsch; Theofilos Tourtas; Naresh Polisetti; Jörg Klenke; Katrin Skerl; Christian Wüllner; Christof Donitzky; Friedrich E Kruse; Jan Kremers; Christian M Hammer
Journal:  PLoS One       Date:  2015-09-11       Impact factor: 3.240

9.  Distribution and Repeatability of Corneal Astigmatism Measurements (Magnitude and Axis) Evaluated With Color Light Emitting Diode Reflection Topography.

Authors:  Anastasios John Kanellopoulos; George Asimellis
Journal:  Cornea       Date:  2015-08       Impact factor: 2.651

10.  Assessing the correlation between swept-source optical coherence tomography lens density pattern analysis and best-corrected visual acuity in patients with cataracts.

Authors:  Hugo Bourdon; Liem Trinh; Mathieu Robin; Christophe Baudouin
Journal:  BMJ Open Ophthalmol       Date:  2021-05-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.