Literature DB >> 30045869

Stability of Human Immunodeficiency Virus Serological Markers in Samples Collected as HemaSpot and Whatman 903 Dried Blood Spots.

Mark M Manak1, Holly R Hack2, Ashley L Shutt2, Brook A Danboise3, Linda L Jagodzinski3, Sheila A Peel3.   

Abstract

Dried blood spots (DBS) are frequently used in clinical testing for biosurveillance, infectious disease and confirmatory testing, and clinical trials, particularly for populations in remote areas. The HemaSpot-HF blood collection device (HS) provides an alternative format to the Whatman 903 cards (903) to simplify sample collection and processing. In this study, the performance of the HS was compared to that of the 903 using previously characterized clinical specimens and HIV seroconversion panels known to exhibit markers of early human immunodeficiency virus (HIV) infection. HS and 903 samples were prepared and tested by Bio-Rad GS HIV Combo Ag/Ab enzyme immunoassay (EIA), GS HIV-1/-2 Plus O EIA, GS HIV-1 Western blot, and HIV-1 Geenius assays. Both HS and 903 performed well for up to 6 months at room temperature, but a marked loss of Western blot and low titer antibody signals from early infection samples was observed in samples stored for 180 days at elevated (37 to 45°C) temperatures and high humidity (95%). HemaSpot samples placed in sealed bags with additional desiccant were protected from degradation and showed improved signal recovery relative to that of the 903. HS was easier to use than the 903 and showed higher sensitivity and reproducibility for early infection samples and improved stability.

Entities:  

Keywords:  HemaSpot; Whatman 903 cards; diagnostics; dried blood spot; human immunodeficiency virus; stability

Mesh:

Substances:

Year:  2018        PMID: 30045869      PMCID: PMC6156313          DOI: 10.1128/JCM.00933-18

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  37 in total

1.  Long term stability of HBsAg, anti-HBc and anti-HCV in dried blood spot samples and eluates.

Authors:  Georgina McAllister; Samantha Shepherd; Kate Templeton; Celia Aitken; Rory Gunson
Journal:  J Clin Virol       Date:  2015-07-29       Impact factor: 3.168

2.  HemaSpot, a Novel Blood Storage Device for HIV-1 Drug Resistance Testing.

Authors:  K Brooks; A DeLong; M Balamane; L Schreier; M Orido; M Chepkenja; E Kemboi; M D'Antuono; P A Chan; W Emonyi; L Diero; M Coetzer; R Kantor
Journal:  J Clin Microbiol       Date:  2015-11-11       Impact factor: 5.948

3.  Dried blood spots for HIV-1 drug resistance genotyping in decentralized settings in Senegal.

Authors:  Abou Abdallah Malick Diouara; Halimatou Diop-Ndiaye; Khady Kebe-Fall; Edmond Tchiakpè; Ousseynou Ndiaye; Ahidjo Ayouba; Martine Peeters; Souleymane Mboup; Coumba Toure Kane
Journal:  J Med Virol       Date:  2013-10-01       Impact factor: 2.327

4.  Dried blood spots (DBS): a valuable tool for HIV surveillance in developing/tropical countries.

Authors:  Sunil S Solomon; Suniti Solomon; Irma I Rodriguez; Stephen T McGarvey; A K Ganesh; S P Thyagarajan; Anish P Mahajan; Kenneth H Mayer
Journal:  Int J STD AIDS       Date:  2002-01       Impact factor: 1.359

5.  Comparison of Ahlstrom grade 226, Munktell TFN, and Whatman 903 filter papers for dried blood spot specimen collection and subsequent HIV-1 load and drug resistance genotyping analysis.

Authors:  Erin Rottinghaus; Ebi Bile; Mosetsanagape Modukanele; Maruping Maruping; Madisa Mine; John Nkengasong; Chunfu Yang
Journal:  J Clin Microbiol       Date:  2012-10-17       Impact factor: 5.948

6.  Heterogeneity of Herpes Simplex Virus Type 2 Seroprevalence From a National Probability Survey In Mexico, 2012.

Authors:  Miguel Angel Sanchez-Aleman; Yamira Georgina Del Villar-Tapia; Juan Pablo Gutierrez; Santa Garcia-Cisneros; Ma Leonidez Olamendi-Portugal; Antonia Herrera-Ortiz; Manuel Velazquez-Meza; Carlos J Conde-Glez
Journal:  Sex Transm Dis       Date:  2018-02       Impact factor: 2.830

7.  Dried blood spots are an acceptable and useful HIV surveillance tool in a remote developing world setting.

Authors:  S S Solomon; S Pulimi; I I Rodriguez; S K Chaguturu; S K Satish Kumar; K H Mayer; S Solomon
Journal:  Int J STD AIDS       Date:  2004-10       Impact factor: 1.359

8.  Evaluation of four commercial virological assays for early infant HIV-1 diagnosis using dried blood specimens.

Authors:  Patricia Alvarez; Luis Prieto; Leticia Martín; Jacinta Obiang; Pedro Avedillo; Antonio Vargas; Pablo Rojo; Carolina Fernández McPhee; Leticia Sanz Canalejas; Agustín Benito; José Tomás Ramos; África Holguín
Journal:  Pediatr Res       Date:  2016-09-21       Impact factor: 3.756

9.  Evaluation of the human immunodeficiency virus type 1 and 2 antibodies detection in dried whole blood spots (DBS) samples.

Authors:  Andréa Cauduro de Castro; Luiz Gustavo dos Anjos Borges; Ricardo da Silva de Souza; Melina Grudzinski; Pedro Alves D'Azevedo
Journal:  Rev Inst Med Trop Sao Paulo       Date:  2008 May-Jun       Impact factor: 1.846

10.  Evaluation of dried blood spots with a multiplex assay for measuring recent HIV-1 infection.

Authors:  Kelly A Curtis; Krystin M Ambrose; M Susan Kennedy; S Michele Owen
Journal:  PLoS One       Date:  2014-09-18       Impact factor: 3.240

View more
  10 in total

1.  Stimulant Use and Study Protocol Completion: Assessing the Ability of Men Who Have Sex with Men to Collect Dried Blood Spots for Laboratory Measurement of HIV Viral Load.

Authors:  Richard A Teran; Adam W Carrico; Keith J Horvath; Martin J Downing; Mary Ann Chiasson; Suzan M Walters; Sabina Hirshfield
Journal:  Arch Sex Behav       Date:  2019-10-19

2.  Screening for Human Immunodeficiency Virus Infection by Use of a Fourth-Generation Antigen/Antibody Assay and Dried Blood Spots: In-Depth Analysis of Sensitivity and Performance Assessment in a Cross-Sectional Study.

Authors:  Karl Stefic; Jerome Guinard; Gilles Peytavin; Leïla Saboni; Cécile Sommen; Claire Sauvage; Florence Lot; Syria Laperche; Annie Velter; Francis Barin
Journal:  J Clin Microbiol       Date:  2019-12-23       Impact factor: 5.948

3.  Quantification of HIV-1 RNA Among Men Who Have Sex With Men Using an At-Home Self-Collected Dried Blood Spot Specimen: Feasibility Study.

Authors:  Sabina Hirshfield; Richard A Teran; Martin J Downing; Mary Ann Chiasson; Hong-Van Tieu; Laura Dize; Charlotte A Gaydos
Journal:  JMIR Public Health Surveill       Date:  2018-11-01

4.  The feasibility of modified HIV and antiretroviral drug testing using self-collected dried blood spots from men who have sex with men.

Authors:  Wei Luo; Vickie Sullivan; Pollyanna R Chavez; Sarah E Wiatrek; Maria Zlotorzynska; Amy Martin; Rebecca Rossetti; Travis Sanchez; Patrick Sullivan; Robin J MacGowan; S Michele Owen; Silvina Masciotra
Journal:  BMC Infect Dis       Date:  2021-05-05       Impact factor: 3.090

5.  Patterned Dried Blood Spot Cards for the Improved Sampling of Whole Blood.

Authors:  Keith R Baillargeon; Jessica C Brooks; Philip R Miljanic; Charles R Mace
Journal:  ACS Meas Sci Au       Date:  2021-09-17

Review 6.  Overview of the Analytes Applied in Genotypic HIV Drug Resistance Testing.

Authors:  Hezhao Ji; Paul Sandstrom
Journal:  Pathogens       Date:  2022-06-29

7.  Performance of a Novel Low-Cost, Instrument-Free Plasma Separation Device for HIV Viral Load Quantification and Determination of Treatment Failure in People Living with HIV in Malaysia: a Diagnostic Accuracy Study.

Authors:  Stanley Luchters; David A Anderson; Minh D Pham; Berhan A Haile; Iskandar Azwa; Adeeba Kamarulzaman; Nishaan Raman; Alireza Saeidi; Maria Kahar Bador; Margaret Tan; Jiawei Zhu; Yi Feng; Julian H Elliott; Mary L Garcia; Fan Li; Suzanne M Crowe
Journal:  J Clin Microbiol       Date:  2019-03-28       Impact factor: 5.948

Review 8.  Dried Blood Spot Tests for the Diagnosis and Therapeutic Monitoring of HIV and Viral Hepatitis B and C.

Authors:  Edouard Tuaillon; Dramane Kania; Amandine Pisoni; Karine Bollore; Fabien Taieb; Esther Nina Ontsira Ngoyi; Roxane Schaub; Jean-Christophe Plantier; Alain Makinson; Philippe Van de Perre
Journal:  Front Microbiol       Date:  2020-03-09       Impact factor: 5.640

9.  Optimization and Stability Testing of Four Commercially Available Dried Blood Spot Devices for Estimating Measles and Rubella IgG Antibodies.

Authors:  Ojas Kaduskar; Vaishali Bhatt; Christine Prosperi; Kyla Hayford; Alvira Z Hasan; Gururaj Rao Deshpande; Bipin Tilekar; Jeromie Wesley Vivian Thangaraj; Muthusamy Santhosh Kumar; Nivedita Gupta; Manoj V Murhekar; William J Moss; Sanjay M Mehendale; Lucky Sangal; Gajanan Sapkal
Journal:  mSphere       Date:  2021-07-14       Impact factor: 4.389

10.  Diagnostic Accuracy of Dried Blood Spots Collected on HemaSpot HF Devices Compared to Venous Blood Specimens To Estimate Measles and Rubella Seroprevalence.

Authors:  Christine Prosperi; Ojas Kaduskar; Gajanan N Sapkal; Kyla Hayford; Vaishali Bhatt; Alvira Z Hasan; Jeromie W Vivian Thangaraj; Muthusamy S Kumar; R Sabarinathan; Saravana Kumar; Augustine Duraiswamy; Gururaj Rao Deshpande; Ullas Padinjaremattathil Thankappan; Sanjay L Chauhan; Ragini N Kulkarni; Avi Kumar Bansal; Itta K Chaaithanya; Neha R Salvi; Sandeep Sharma; William J Moss; Lucky Sangal; Nivedita Gupta; Manoj V Murherkar; Sanjay M Mehendale
Journal:  mSphere       Date:  2021-07-14       Impact factor: 4.389

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.