Literature DB >> 30033935

Development of a novel mouth model as an alternative tool to test the effectiveness of an in vivo EPR dosimetry system.

Kyo Kobayashi1, Ruhong Dong, Roberto Javier Nicolalde, Paul Calderon, Gaixin Du, Benjamin B Williams, Masaichi-Chang-Il Lee, Harold M Swartz, Ann Barry Flood.   

Abstract

In a large-scale radiation event, thousands may be exposed to unknown amounts of radiation, some of which may be life-threatening without immediate attention. In such situations, a method to quickly and reliably estimate dose would help medical responders triage victims to receive life-saving care. We developed such a method using electron paramagnetic resonance (EPR) to make in vivo measurements of the maxillary incisors. This report provides evidence that the use of in vitro studies can provide data that are fully representative of the measurements made in vivo. This is necessary because, in order to systematically test and improve the reliability and accuracy of the dose estimates made with our EPR dosimetry system, it is important to conduct controlled studies in vitro using irradiated human teeth. Therefore, it is imperative to validate whether our in vitro models adequately simulate the measurements made in vivo, which are intended to help guide decisions on triage after a radiation event. Using a healthy volunteer with a dentition gap that allows using a partial denture, human teeth were serially irradiated in vitro and then, using a partial denture, placed in the volunteer's mouth for measurements. We compared dose estimates made using in vivo measurements made in the volunteer's mouth to measurements made on the same teeth in our complex mouth model that simulates electromagnetic and anatomic properties of the mouth. Our results demonstrate that this mouth model can be used in in vitro studies to develop the system because these measurements appropriately model in vivo conditions.

Entities:  

Mesh:

Year:  2018        PMID: 30033935      PMCID: PMC6282024          DOI: 10.1088/1361-6560/aad518

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  20 in total

1.  An improved external loop resonator for in vivo L-band EPR spectroscopy.

Authors:  Ildar Salikhov; Hiroshi Hirata; Tadeusz Walczak; Harold M Swartz
Journal:  J Magn Reson       Date:  2003-09       Impact factor: 2.229

Review 2.  EPR dosimetry with tooth enamel: A review.

Authors:  Paola Fattibene; Freddy Callens
Journal:  Appl Radiat Isot       Date:  2010-06-04       Impact factor: 1.513

3.  Evaluating the Special Needs of The Military for Radiation Biodosimetry for Tactical Warfare Against Deployed Troops: Comparing Military to Civilian Needs for Biodosimetry Methods.

Authors:  Ann Barry Flood; Arif N Ali; Holly K Boyle; Gaixin Du; Victoria A Satinsky; Steven G Swarts; Benjamin B Williams; Eugene Demidenko; Wilson Schreiber; Harold M Swartz
Journal:  Health Phys       Date:  2016-08       Impact factor: 1.316

4.  Rapid radiation dose assessment for radiological public health emergencies: roles of NIAID and BARDA.

Authors:  Marcy B Grace; Brian R Moyer; Joanna Prasher; Kenneth D Cliffer; Narayani Ramakrishnan; Joseph Kaminski; C Norman Coleman; Ronald G Manning; Bert W Maidment; Richard Hatchett
Journal:  Health Phys       Date:  2010-02       Impact factor: 1.316

5.  Advances in a framework to compare bio-dosimetry methods for triage in large-scale radiation events.

Authors:  Ann Barry Flood; Holly K Boyle; Gaixin Du; Eugene Demidenko; Roberto J Nicolalde; Benjamin B Williams; Harold M Swartz
Journal:  Radiat Prot Dosimetry       Date:  2014-04-11       Impact factor: 0.972

Review 6.  Advances in in vivo EPR Tooth BIOdosimetry: Meeting the targets for initial triage following a large-scale radiation event.

Authors:  Ann Barry Flood; Benjamin B Williams; Wilson Schreiber; Gaixin Du; Victoria A Wood; Maciej M Kmiec; Sergey V Petryakov; Eugene Demidenko; Harold M Swartz
Journal:  Radiat Prot Dosimetry       Date:  2016-07-15       Impact factor: 0.972

7.  A Deployable In Vivo EPR Tooth Dosimeter for Triage After a Radiation Event Involving Large Populations.

Authors:  Benjamin B Williams; Ruhong Dong; Ann Barry Flood; Oleg Grinberg; Maciej Kmiec; Piotr N Lesniewski; Thomas P Matthews; Roberto J Nicolalde; Tim Raynolds; Ildar K Salikhov; Harold M Swartz
Journal:  Radiat Meas       Date:  2011-09-01       Impact factor: 1.898

8.  In vivo EPR tooth dosimetry for triage after a radiation event involving large populations.

Authors:  Benjamin B Williams; Ann Barry Flood; Ildar Salikhov; Kyo Kobayashi; Ruhong Dong; Kevin Rychert; Gaixin Du; Wilson Schreiber; Harold M Swartz
Journal:  Radiat Environ Biophys       Date:  2014-04-08       Impact factor: 1.925

9.  Physically-based biodosimetry using in vivo EPR of teeth in patients undergoing total body irradiation.

Authors:  Benjamin B Williams; Ruhong Dong; Roberto J Nicolalde; Thomas P Matthews; David J Gladstone; Eugene Demidenko; Bassem I Zaki; Ildar K Salikhov; Piotr N Lesniewski; Harold M Swartz
Journal:  Int J Radiat Biol       Date:  2011-06-23       Impact factor: 2.694

10.  Assessment of biodosimetry methods for a mass-casualty radiological incident: medical response and management considerations.

Authors:  Julie M Sullivan; Pataje G S Prasanna; Marcy B Grace; Lynne K Wathen; Rodney L Wallace; John F Koerner; C Norman Coleman
Journal:  Health Phys       Date:  2013-12       Impact factor: 1.316

View more