Systemic blood pressure trends and antihypertensive utilization following continuous-flow left ventricular assist device implantation: an analysis of the interagency registry for mechanically assisted circulatory support.

Adham Elmously1, Andreas R de Biasi1, Donald A Risucci2,3, Berhane Worku1, Evelyn M Horn4, Arash Salemi1.   

Abstract

BACKGROUND: Elevated systemic blood pressure (SBP) has been linked to complications in Continuous-flow left ventricular assist devices (CF-LVADs), including stroke and pump thrombosis. We queried Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) to describe the response of SBP to CF-LVAD implantation and to delineate contemporary trends in antihypertensive (AH) utilization for patients with these pumps.
METHODS: We identified all CF-LVAD implantations in patients older than 18 years from 2006-2014, excluding those whose durations were less than 30 days. Pre-implant patient demographics and characteristics were obtained for each record. SBPs [i.e., mean arterial pressures (MAPs)], AH-use data, and vital status were tabulated, extending up to 5 years following implantation.
RESULTS: A total of 10,329 CF-LVAD implantations were included for study. Post-implant, SBPs increased rapidly during the first 3 months but plateaued thereafter; AH utilization mirrored this trend. By 6 months, mean MAPs climbed 12.2% from 77.6 mmHg (95% CI: 77.4-77.8) pre-implantation to 87.1 mmHg (95% CI: 86.7-87.4) and patients required a mean of 1.8 AH medications (95% CI: 1.75-1.78) -a 125% increase from AH use at 1-week post-implantation (0.8 AHs/patient, 95% CI: 0.81-0.83) but a 5.3% decrease from pre-implant utilization (1.9 AHs/patient, 95% CI: 1.90-1.92). Once medication changes stabilized, the most common AH regimens were lone beta blockade (15%, n=720) and a beta blocker plus an ACE inhibitor (14%, n=672).
CONCLUSIONS: SBP rises rapidly after CF-LVAD implantation, stabilizing after 3 months, and is matched by concomitant changes in AH utilization; this AH use has increased over consecutive implant years.

Entities:  

Keywords:  Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS); Systemic blood pressure (SBP); antihypertensive (AH); continuous-flow (CF); left ventricular assist device (LVAD)

Year:  2018        PMID: 29997951      PMCID: PMC6006088          DOI: 10.21037/jtd.2018.05.24

Source DB:  PubMed          Journal:  J Thorac Dis        ISSN: 2072-1439            Impact factor:   2.895


  14 in total

1.  Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation.

Authors:  Keith D Aaronson; Mark S Slaughter; Leslie W Miller; Edwin C McGee; William G Cotts; Michael A Acker; Mariell L Jessup; Igor D Gregoric; Pranav Loyalka; O H Frazier; Valluvan Jeevanandam; Allen S Anderson; Robert L Kormos; Jeffrey J Teuteberg; Wayne C Levy; David C Naftel; Richard M Bittman; Francis D Pagani; David R Hathaway; Steven W Boyce
Journal:  Circulation       Date:  2012-05-22       Impact factor: 29.690

2.  Sixth INTERMACS annual report: a 10,000-patient database.

Authors:  James K Kirklin; David C Naftel; Francis D Pagani; Robert L Kormos; Lynne W Stevenson; Elizabeth D Blume; Marissa A Miller; J T Baldwin; J Timothy Baldwin; James B Young
Journal:  J Heart Lung Transplant       Date:  2014-04-21       Impact factor: 10.247

3.  Methods for dealing with time-dependent confounding.

Authors:  R M Daniel; S N Cousens; B L De Stavola; M G Kenward; J A C Sterne
Journal:  Stat Med       Date:  2012-12-03       Impact factor: 2.373

4.  The 2013 International Society for Heart and Lung Transplantation Guidelines for mechanical circulatory support: executive summary.

Authors:  David Feldman; Salpy V Pamboukian; Jeffrey J Teuteberg; Emma Birks; Katherine Lietz; Stephanie A Moore; Jeffrey A Morgan; Francisco Arabia; Mary E Bauman; Hoger W Buchholz; Mario Deng; Marc L Dickstein; Aly El-Banayosy; Tonya Elliot; Daniel J Goldstein; Kathleen L Grady; Kylie Jones; Katarzyna Hryniewicz; Ranjit John; Annemarie Kaan; Shimon Kusne; Matthias Loebe; M Patricia Massicotte; Nader Moazami; Paul Mohacsi; Martha Mooney; Thomas Nelson; Francis Pagani; William Perry; Evgenij V Potapov; J Eduardo Rame; Stuart D Russell; Erik N Sorensen; Benjamin Sun; Martin Strueber; Abeel A Mangi; Michael G Petty; Joseph Rogers
Journal:  J Heart Lung Transplant       Date:  2013-02       Impact factor: 10.247

5.  The vexing problem of thrombosis in long-term mechanical circulatory support.

Authors:  Mandeep R Mehra; Garrick C Stewart; Patricia A Uber
Journal:  J Heart Lung Transplant       Date:  2013-12-10       Impact factor: 10.247

6.  An analysis of pump thrombus events in patients in the HeartWare ADVANCE bridge to transplant and continued access protocol trial.

Authors:  Samer S Najjar; Mark S Slaughter; Francis D Pagani; Randall C Starling; Edwin C McGee; Peter Eckman; Antone J Tatooles; Nader Moazami; Robert L Kormos; David R Hathaway; Kevin B Najarian; Geetha Bhat; Keith D Aaronson; Steven W Boyce
Journal:  J Heart Lung Transplant       Date:  2013-12-12       Impact factor: 10.247

7.  Systolic blood pressure on discharge after left ventricular assist device insertion is associated with subsequent stroke.

Authors:  Michael E Nassif; Anjan Tibrewala; David S Raymer; Adam Andruska; Eric Novak; Justin M Vader; Akinobu Itoh; Scott C Silvestry; Gregory A Ewald; Shane J LaRue
Journal:  J Heart Lung Transplant       Date:  2014-10-23       Impact factor: 10.247

8.  Change in health-related quality of life from before to after destination therapy mechanical circulatory support is similar for older and younger patients: analyses from INTERMACS.

Authors:  Kathleen L Grady; David C Naftel; Susan Myers; Mary Amanda Dew; Gerdi Weidner; John A Spertus; Katharine Idrissi; Hochang B Lee; Edwin C McGee; James K Kirklin
Journal:  J Heart Lung Transplant       Date:  2014-10-31       Impact factor: 10.247

9.  Validity and reliability of a novel slow cuff-deflation system for noninvasive blood pressure monitoring in patients with continuous-flow left ventricular assist device.

Authors:  Gregg M Lanier; Khristine Orlanes; Yacki Hayashi; Jennifer Murphy; Margaret Flannery; Rosie Te-Frey; Nir Uriel; Melana Yuzefpolskaya; Donna M Mancini; Yoshifumi Naka; Hiroo Takayama; Ulrich P Jorde; Ryan T Demmer; Paolo C Colombo
Journal:  Circ Heart Fail       Date:  2013-06-27       Impact factor: 8.790

Review 10.  Hypertension: an unstudied potential risk factor for adverse outcomes during continuous flow ventricular assist device support.

Authors:  Lauren T Wasson; Melana Yuzefpolskaya; Michiyori Wakabayashi; Hiroo Takayama; Yoshifumi Naka; Nir Uriel; Ulrich P Jorde; Ryan T Demmer; Paolo C Colombo
Journal:  Heart Fail Rev       Date:  2015-05       Impact factor: 4.214

View more
  1 in total

1.  The role of renin-angiotensin system in patients with left ventricular assist devices.

Authors:  Alexandros Briasoulis; Ernesto Ruiz Duque; Dimitrios Mouselimis; Anastasios Tsarouchas; Constantinos Bakogiannis; Paulino Alvarez
Journal:  J Renin Angiotensin Aldosterone Syst       Date:  2020 Oct-Dec       Impact factor: 1.636

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.