Comprehensive reconstruction of multi-shot multi-channel diffusion data using mussels.

Merry Mani, Vincent Magnotta, Douglas Kelley, Mathews Jacob.   

Abstract

Echo planar imaging (EPI)-based magnetic resonance imaging (MRI) data are often corrupted by Nyquist ghost artifacts resulting from odd-even shifts of the EPI read-outs. Algorithms that corrects for the Nyquist ghost artifacts rely on calibration scans that are collected prior to the data acquisition. However, a more complex pattern of ghosting artifacts arises when diffusion-weighted data are acquired using segmented k-space EPI read-outs. The additional under-sampling present in the segmented acquisitions and the inter-shot motion during diffusion weighted acquistion cause ghosting artifacts in addition to the EPI ghosting arising from odd-even shifts. We propose a comprehensive method that can remove the Nyquist-ghosting artifacts as well as the inter-shot motion-induced ghosting artifacts in diffusion weighted images in a single step from partial Fourier data without the need for a calibration scan. We show very high quality diffusion data recovery using the proposed method.

Entities:  

Mesh:

Year:  2016        PMID: 28268519      PMCID: PMC7902245          DOI: 10.1109/EMBC.2016.7590897

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  5 in total

1.  A new phase correction method in NMR imaging based on autocorrelation and histogram analysis.

Authors:  C B Ahn; Z H Cho
Journal:  IEEE Trans Med Imaging       Date:  1987       Impact factor: 10.048

2.  Artifact reduction in EPI with phase-encoded reference scan.

Authors:  X Hu; T H Le
Journal:  Magn Reson Med       Date:  1996-07       Impact factor: 4.668

3.  P-LORAKS: Low-rank modeling of local k-space neighborhoods with parallel imaging data.

Authors:  Justin P Haldar; Jingwei Zhuo
Journal:  Magn Reson Med       Date:  2015-05-07       Impact factor: 4.668

4.  Analysis and correction of motion artifacts in diffusion weighted imaging.

Authors:  A W Anderson; J C Gore
Journal:  Magn Reson Med       Date:  1994-09       Impact factor: 4.668

5.  Reference-free single-pass EPI Nyquist ghost correction using annihilating filter-based low rank Hankel matrix (ALOHA).

Authors:  Juyoung Lee; Kyong Hwan Jin; Jong Chul Ye
Journal:  Magn Reson Med       Date:  2016-02-17       Impact factor: 4.668

  5 in total
  6 in total

1.  Highly accelerated multishot echo planar imaging through synergistic machine learning and joint reconstruction.

Authors:  Berkin Bilgic; Itthi Chatnuntawech; Mary Kate Manhard; Qiyuan Tian; Congyu Liao; Siddharth S Iyer; Stephen F Cauley; Susie Y Huang; Jonathan R Polimeni; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-05-20       Impact factor: 4.668

2.  Navigator-Free EPI Ghost Correction With Structured Low-Rank Matrix Models: New Theory and Methods.

Authors:  Rodrigo A Lobos; Tae Hyung Kim; W Scott Hoge; Justin P Haldar
Journal:  IEEE Trans Med Imaging       Date:  2018-04-02       Impact factor: 10.048

3.  Simultaneous auto-calibration and gradient delays estimation (SAGE) in non-Cartesian parallel MRI using low-rank constraints.

Authors:  Wenwen Jiang; Peder E Z Larson; Michael Lustig
Journal:  Magn Reson Med       Date:  2018-03-09       Impact factor: 4.668

4.  Improving parallel imaging by jointly reconstructing multi-contrast data.

Authors:  Berkin Bilgic; Tae Hyung Kim; Congyu Liao; Mary Kate Manhard; Lawrence L Wald; Justin P Haldar; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2018-01-10       Impact factor: 4.668

5.  Multi-shot sensitivity-encoded diffusion data recovery using structured low-rank matrix completion (MUSSELS).

Authors:  Merry Mani; Mathews Jacob; Douglas Kelley; Vincent Magnotta
Journal:  Magn Reson Med       Date:  2016-08-23       Impact factor: 4.668

6.  Improved MUSSELS reconstruction for high-resolution multi-shot diffusion weighted imaging.

Authors:  Merry Mani; Hemant Kumar Aggarwal; Vincent Magnotta; Mathews Jacob
Journal:  Magn Reson Med       Date:  2019-12-02       Impact factor: 4.668

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.