| Literature DB >> 29984912 |
Daniel Keene1,2, Ahran Arnold1,2, Matthew J Shun-Shin1,2, James P Howard1,2, Sm Afzal Sohaib1, Philip Moore3,4, Mark Tanner5, Norman Quereshi6, Amal Muthumala4,7, Badrinathan Chandresekeran8, Paul Foley8, Francisco Leyva9, Shaumik Adhya10, Emanuela Falaschetti11, Hilda Tsang11, Pugal Vijayaraman12, John G F Cleland1, Berthold Stegemann13, Darrel P Francis1,2, Zachary I Whinnett1,2.
Abstract
AIMS: In patients with heart failure and a pathologically prolonged PR interval, left ventricular (LV) filling can be improved by shortening atrioventricular delay using His-bundle pacing. His-bundle pacing delivers physiological ventricular activation and has been shown to improve acute haemodynamic function in this group of patients. In the HOPE-HF (His Optimized Pacing Evaluated for Heart Failure) trial, we are investigating whether these acute haemodynamic improvements translate into improvements in exercise capacity and heart failure symptoms. METHODS ANDEntities:
Keywords: Atrioventricular delay; Heart failure; His-bundle pacing; Optimization
Mesh:
Year: 2018 PMID: 29984912 PMCID: PMC6165934 DOI: 10.1002/ehf2.12315
Source DB: PubMed Journal: ESC Heart Fail ISSN: 2055-5822
Figure 1Potential pacing methods for atrioventricular (AV) delay optimization. His‐bundle pacing, biventricular (BiV) pacing, and right ventricular (RV) pacing are all potential methods for shortening a pathologically long AV delay. His‐bundle pacing does not prolong left ventricular activation time, when applied to patients with a narrow QRS duration, whereas BiV pacing and RV pacing prolong left ventricular activation time.
Inclusion and exclusion criteria (EF is left ventricular ejection fraction)
| Inclusion criteria |
| Age over 18 years |
| EF ≤ 35% or EF 36–40% with BNP > 250 pg/mL |
| NYHA class II–IV |
| Sinus rhythm |
| PR interval ≥ 200 ms |
| QRS duration ≤ 140 ms or prolonged QRS duration with typical RBBB morphology |
| Exclusion criteria |
| Permanent or persistent AF |
| Paroxysmal AF with history of sustained AF (≥24 h) in the 6 months prior to screening |
| Patients who are unable to perform cardiopulmonary exercise testing |
| Lack of capacity to consent |
| Other serious medical condition with life expectancy of <1 year |
| Pregnancy |
AF, atrial fibrillation; NYHA, New York Heart Association; RBBB, right bundle branch block.
Figure 2(A) Intended area within right atrium for implantation of the His pacing lead. The target area is where the non‐branching part of the His bundle sits above the tricuspid valve on the right atrial—left ventricular part of the membranous septum. (B) Appearance of a single cardiac cycle recorded on an EP system, from a well‐positioned His lead. Note that the atrial component (A) is less than half the size of the ventricular component (V). There is a His signal (H) between the two. This appearance suggests a favourable location. (C) The electrogram can also be displayed using the Pace–Sense Analyser. It is advisable to measure initially a unipolar signal utilizing the atrial channel with a gain setting of 0.05 mV/mm and a sweep speed of 50–100 mm/s. The ventricular channel is not sufficiently sensitive to detect His potentials. (D) This anterior–posterior projection radiographic image shows the typical anatomical location for the His lead (labelled). (E) Rhythm strip showing successful His‐bundle pacing. RV, right ventricular.
Figure 3Differences between selective and non‐selective His pacing. (A) Normal intrinsic conduction. The electrocardiographic imaging (Medtronic Inc., Minneapolis, MN, USA) activation map shows rapid activation (each ventricle has homogenous colouring). (B) Selective His‐bundle pacing. Ventricular activation occurs solely via the His‐Purkinje system, giving a normal QRS and normal activation map. The middle panel shows the short delay between the pacing spike and the onset of ventricular activation. (C) Non‐selective His‐bundle pacing, during which ventricular activation occurs via both local myocardial capture [seen as early activation in right ventricle (RV) (red colour)] and activation via the His‐Purkinje system. Left ventricular (LV) activation time and pattern is the same as during intrinsic activation and with selective His pacing because activation of the LV occurs via the His‐Purkinje system. AP, anterior‐posterior orientation; LAD, left anterior descending; PA, posterior‐anterior orientation.
Figure 4Patient study flow chart (AV, atrioventricular; BNP, B‐type natriuretic protein; ICD, implantable cardioverter defibrillator; QOL, quality of life).
Figure 5Atrioventricular (AV) delay optimization protocol. The relative change in systolic blood pressure (SBP) between 8 beats of AAI pacing and 8 beats of dual chamber atrial synchronous–His pacing at a given atrioventricular delay (AVD) is determined [AV delay = 80 ms in this example (top left)]. This is a single alternation (plotted bottom left). A minimum of six alternations are made for each AVD (middle sections top and bottom). This process is repeated for each AV delay between 40 and 320 ms (less if intrinsic AV conduction occurs before 320 ms). The optimal AV delay is then derived from the plotted parabola (bottom right). In this example, the optimal AV delay was 160 ms. BP, blood pressure; ECG, electrocardiogram.