Literature DB >> 33651211

Innovations in Cardiac Implantable Electronic Devices.

Khurrum Khan1, Jitae A Kim2, Andra Gurgu3, Muzamil Khawaja2, Dragos Cozma3, Mihail G Chelu4.   

Abstract

Cardiac implantable electronic devices (CIEDs) are essential for the management of a variety of cardiac conditions, including tachyarrhythmias, bradyarrhythmias, and medically refractory heart failure (HF). Recent advancements in CIED technology have led to innovative solutions that overcome shortcomings associated with traditional devices or address unmet needs. Leadless pacemakers, subcutaneous implantable cardioverter defibrillators (ICDs), and extravascular ICDs eliminate lead-related complications common with conventional pacemakers or ICDs. Conduction system pacing (His bundle pacing and left bundle branch pacing) is a more physiologic method of pacing and avoids the deleterious consequences associated with long-term right ventricular pacing. For HF-related devices, cardiac contractility modulation is an emerging therapy that bridges a gap for many patients ineligible for cardiac resynchronization therapy and has been shown to improve HF symptoms and decrease hospitalizations and mortality in select patients. Implantable pulmonary artery pressure monitors help guide HF management and reduce hospitalizations. Lastly, new phrenic nerve stimulating devices are being utilized to treat central sleep apnea, a common comorbidity associated with HF. While further long-term studies are still underway for many of these new technologies, it is anticipated that these devices will become indispensable therapeutics in the expanding cardiovascular armamentarium.
© 2021. Springer Science+Business Media, LLC, part of Springer Nature.

Entities:  

Keywords:  CIED; Electrophysiology; Innovation; Novel technology

Mesh:

Year:  2021        PMID: 33651211     DOI: 10.1007/s10557-021-07163-5

Source DB:  PubMed          Journal:  Cardiovasc Drugs Ther        ISSN: 0920-3206            Impact factor:   3.947


  94 in total

1.  Lessons from the first patient with an implanted pacemaker: 1958-2001.

Authors:  Berit Larsson; Håkan Elmqvist; Lars Rydén; Hans Schüller
Journal:  Pacing Clin Electrophysiol       Date:  2003-01       Impact factor: 1.976

2.  Prospective evaluation of feasibility and electrophysiologic and echocardiographic characteristics of left bundle branch area pacing.

Authors:  Pugazhendhi Vijayaraman; Faiz A Subzposh; Angela Naperkowski; Ragesh Panikkath; Kaitlyn John; Vernon Mascarenhas; Terry D Bauch; Weijian Huang
Journal:  Heart Rhythm       Date:  2019-05-25       Impact factor: 6.343

Review 3.  The effects of right ventricular apical pacing on ventricular function and dyssynchrony implications for therapy.

Authors:  Laurens F Tops; Martin J Schalij; Jeroen J Bax
Journal:  J Am Coll Cardiol       Date:  2009-08-25       Impact factor: 24.094

4.  The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009--a World Society of Arrhythmia's project.

Authors:  Harry G Mond; Alessandro Proclemer
Journal:  Pacing Clin Electrophysiol       Date:  2011-06-27       Impact factor: 1.976

Review 5.  Permanent His bundle pacing: shaping the future of physiological ventricular pacing.

Authors:  Parikshit S Sharma; Pugazhendhi Vijayaraman; Kenneth A Ellenbogen
Journal:  Nat Rev Cardiol       Date:  2019-06-27       Impact factor: 32.419

6.  Pacemaker insertion.

Authors:  Maria Kotsakou; Ioannis Kioumis; George Lazaridis; Georgia Pitsiou; Sofia Lampaki; Antonis Papaiwannou; Anastasia Karavergou; Kosmas Tsakiridis; Nikolaos Katsikogiannis; Ilias Karapantzos; Chrysanthi Karapantzou; Sofia Baka; Ioannis Mpoukovinas; Vasilis Karavasilis; Aggeliki Rapti; Georgia Trakada; Athanasios Zissimopoulos; Konstantinos Zarogoulidis; Paul Zarogoulidis
Journal:  Ann Transl Med       Date:  2015-03

7.  Incidence and predictors of short- and long-term complications in pacemaker therapy: the FOLLOWPACE study.

Authors:  Erik O Udo; Nicolaas P A Zuithoff; Norbert M van Hemel; Carel C de Cock; Thijs Hendriks; Pieter A Doevendans; Karel G M Moons
Journal:  Heart Rhythm       Date:  2011-12-17       Impact factor: 6.343

8.  Risk of heart failure- and cardiac death gradually increases with more right ventricular pacing.

Authors:  Erik O Udo; Norbert M van Hemel; Nicolaas P A Zuithoff; Pieter A Doevendans; Karel G M Moons
Journal:  Int J Cardiol       Date:  2015-03-05       Impact factor: 4.164

9.  Permanent leadless cardiac pacing: results of the LEADLESS trial.

Authors:  Vivek Y Reddy; Reinoud E Knops; Johannes Sperzel; Marc A Miller; Jan Petru; Jaroslav Simon; Lucie Sediva; Joris R de Groot; Fleur V Y Tjong; Peter Jacobson; Alan Ostrosff; Srinivas R Dukkipati; Jacob S Koruth; Arthur A M Wilde; Josef Kautzner; Petr Neuzil
Journal:  Circulation       Date:  2014-03-24       Impact factor: 29.690

10.  Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark.

Authors:  Rikke Esberg Kirkfeldt; Jens Brock Johansen; Ellen Aagaard Nohr; Ole Dan Jørgensen; Jens Cosedis Nielsen
Journal:  Eur Heart J       Date:  2013-12-17       Impact factor: 29.983

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.