Literature DB >> 29968157

Stomach interference in 82Rb-PET myocardial perfusion imaging.

Thomas Rasmussen1, Andreas Kjær2, Philip Hasbak2.   

Abstract

BACKGROUND: 82Rubidium(82Rb)-positron-emission-tomography (PET) is prone to some of the same imaging artifacts as single-photon-emission-computed-tomography myocardial perfusion imaging (MPI) including interference from excessive subdiaphragmatic activity. Our aim was to determine associations between clinical parameters and MPI interference including any potential correlation between interference severity and stomach volume. METHODS AND
RESULTS: Two hundred men and women fasted two hours prior to standard clinical 82Rb myocardial perfusion rest/stress PET. Images were analyzed for radiotracer interference between left ventricle myocardium and extracardiac activity. Furthermore, volume of the stomach was measured. Interference, predominantly caused by 82Rb activity in the stomach, was less severe in stress PET compared to rest (absent in 46% vs 31% of patients during stress and rest, P < 0.05). In addition, a large stomach volume was associated with more severe interference in rest (P < 0.05) while a high body mass index was associated with less interference.
CONCLUSION: Among clinical parameters associated with patient size, BMI was the strongest predictor of MPI interference. Furthermore, a large stomach volume was associated with more severe MPI interference, suggesting that sufficient fasting prior to imminent 82Rb PET may be important to reduce interference from adjacent radiotracer activity and consequently improve interpretation of MPI results, especially in small patients.

Entities:  

Keywords:  82Rb-PET; Myocardial perfusion; cardiac imaging; cardiac positron-emission-tomography; interference; myocardial blood flow; myocardial perfusion imaging; rubidium; rubidium PET; subdiagfragmatic interference

Mesh:

Substances:

Year:  2018        PMID: 29968157     DOI: 10.1007/s12350-018-1359-8

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  4 in total

Review 1.  Artifacts and pitfalls in myocardial perfusion imaging.

Authors:  Steven Burrell; Anita MacDonald
Journal:  J Nucl Med Technol       Date:  2006-12

2.  Minimizing liver, bowel, and gastric activity in myocardial perfusion SPECT.

Authors:  A J van Dongen; P P van Rijk
Journal:  J Nucl Med       Date:  2000-08       Impact factor: 10.057

3.  Prone versus supine thallium myocardial SPECT: a method to decrease artifactual inferior wall defects.

Authors:  G M Segall; M J Davis
Journal:  J Nucl Med       Date:  1989-04       Impact factor: 10.057

4.  Myocardial Na,K-ATPase: Clinical aspects.

Authors:  Keld Kjeldsen
Journal:  Exp Clin Cardiol       Date:  2003
  4 in total
  1 in total

1.  Striving to improve 82Rubidium PET MPI accuracy.

Authors:  Ornella Rimoldi
Journal:  J Nucl Cardiol       Date:  2018-08-22       Impact factor: 5.952

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.