Minimizing liver, bowel, and gastric activity in myocardial perfusion SPECT.

A J van Dongen1, P P van Rijk.   

Abstract

UNLABELLED: When using 99mTc-tetrofosmin for myocardial perfusion SPECT, increased liver, intestinal, or gastric activity may create a major problem in the visual and quantitative interpretation Of the inferoposteroseptal walls, particularly at rest. The aim of this study was to determine what measures were required to minimize this extracardial activity.
METHODS: Ninety-seven patients had a SPECT scan at rest without attenuation correction. They were divided into 3 groups. Preparation consisted of no action taken (group 1), 150 mL whole milk 10 min after administration of tetrofosmin (group 2), or 450 mL water 10 min before acquisition (group 3). A further 55 patients had a SPECT scan at rest with attenuation correction. They were also divided into 3 groups, and preparation consisted of 150 mL whole milk 10 min after administration of tetrofosmin (group 4), 450 mL water 10 min before acquisition (group 5), or both whole milk and water (group 6). The presence of activity in liver, bowel, and stomach was determined visually on reconstructed images. Activity was defined as interfering when it might result in either an underestimation or an overestimation of the uptake in the myocardial wall.
RESULTS: Interfering activity was seen in 83% of the patients in group 1, in 74% in group 2, in 33% in group 3, in 61% in group 4, in 67% in group 5, and in 20% of group 6.
CONCLUSION: The interpretation of inferoposteroseptal wall activity on myocardial rest SPECT images is facilitated by having the patient drink both whole milk and water at specified times before data acquisition.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10945520

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  27 in total

1.  Evaluation of (99)  (m)TcN-MPO as a new myocardial perfusion imaging agent in normal dogs and in an acute myocardial infarction canine model: comparison with (99)  (m)Tc-sestamibi.

Authors:  Lihong Bu; Renfei Li; Zhongnan Jin; Xiaofei Wen; Shuang Liu; Baofeng Yang; Baozhong Shen; Xiaoyuan Chen
Journal:  Mol Imaging Biol       Date:  2011-02       Impact factor: 3.488

2.  Procedure guidelines for radionuclide myocardial perfusion imaging.

Authors:  C Anagnostopoulos; M Harbinson; A Kelion; K Kundley; C Y Loong; A Notghi; E Reyes; W Tindale; S R Underwood
Journal:  Heart       Date:  2004-01       Impact factor: 5.994

3.  EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology.

Authors:  B Hesse; K Tägil; A Cuocolo; C Anagnostopoulos; M Bardiés; J Bax; F Bengel; E Busemann Sokole; G Davies; M Dondi; L Edenbrandt; P Franken; A Kjaer; J Knuuti; M Lassmann; M Ljungberg; C Marcassa; P Y Marie; F McKiddie; M O'Connor; E Prvulovich; R Underwood; B van Eck-Smit
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-07       Impact factor: 9.236

4.  The effects of solid food in prevention of intestinal activity in Tc-99m tetrofosmin myocardial perfusion scintigraphy.

Authors:  Adil Boz; Firat Gungor; Binnur Karayalçin; Akin Yildiz
Journal:  J Nucl Cardiol       Date:  2003 Mar-Apr       Impact factor: 5.952

5.  Contributions of subdiaphragmatic activity, attenuation, and diaphragmatic motion to inferior wall artifact in attenuation-corrected Tc-99m myocardial perfusion SPECT.

Authors:  Alexander G Pitman; Victor Kalff; Bruce Van Every; Borghild Risa; Leighton R Barnden; Michael J Kelly
Journal:  J Nucl Cardiol       Date:  2005 Jul-Aug       Impact factor: 5.952

6.  The influence of attenuation and scatter compensation on the apparent distribution of Tc-99m sestamibi in cardiac slices.

Authors:  P H Pretorius; M V Narayanan; S T Dahlberg; J A Leppo; M A King
Journal:  J Nucl Cardiol       Date:  2001 May-Jun       Impact factor: 5.952

7.  Effects of Glycosylation on Biodistribution and Imaging Quality of Necrotic Myocardium of Iodine-131-Labeled Sennidins.

Authors:  Ling Li; Dongjian Zhang; Shengwei Yang; Shaoli Song; Jindian Li; Qin Wang; Cong Wang; Yuanbo Feng; Yicheng Ni; Jian Zhang; Wei Liu; Zhiqi Yin
Journal:  Mol Imaging Biol       Date:  2016-12       Impact factor: 3.488

Review 8.  Taking the perfect nuclear image: quality control, acquisition, and processing techniques for cardiac SPECT, PET, and hybrid imaging.

Authors:  James A Case; Timothy M Bateman
Journal:  J Nucl Cardiol       Date:  2013-10       Impact factor: 5.952

9.  The prevalence and significance of increased gastric wall radiotracer uptake in sestamibi myocardial perfusion SPECT.

Authors:  Ali Gholamrezanezhad; Davoud Moinian; Mohammad Eftekhari; Sahar Mirpour; Hadi Hajimohammadi
Journal:  Int J Cardiovasc Imaging       Date:  2006-03-04       Impact factor: 2.357

10.  The impact of regimented aminophylline use on extracardiac radioisotope activity in patients undergoing regadenoson stress SPECT myocardial perfusion imaging: a substudy of the ASSUAGE trial.

Authors:  Wassim Ballany; Khaled Mansour; Raysa Morales Demori; Mohammed Al-Amoodi; Rami Doukky
Journal:  J Nucl Cardiol       Date:  2014-02-12       Impact factor: 5.952