Literature DB >> 29923832

Photoacoustic imaging of a human vertebra: implications for guiding spinal fusion surgeries.

Joshua Shubert1, Muyinatu A Lediju Bell.   

Abstract

It is well known that there are structural differences between cortical and cancellous bone. However, spinal surgeons currently have no reliable method to non-invasively determine these differences in real-time when choosing the optimal starting point and trajectory to insert pedicle screws and avoid surgical complications associated with breached or weakened bone. This paper explores 3D photoacoustic imaging of a human vertebra to noninvasively differentiate cortical from cancellous bone for this surgical task. We observed that signals from the cortical bone tend to appear as compact, high-amplitude signals, while signals from the cancellous bone have lower amplitudes and are more diffuse. In addition, we discovered that the location of the light source for photoacoustic imaging is a critical parameter that can be adjusted to non-invasively determine the optimal entry point into the pedicle. Once inside the pedicle, statistically significant differences in the contrast and SNR of signals originating from the cancellous core of the pedicle (when compared to signals originating from the surrounding cortical bone) were obtained with laser energies of 0.23-2.08 mJ (p  <  0.05). Similar quantitative differences were observed with an energy of 1.57 mJ at distances  ⩾6 mm from the cortical bone of the pedicle. These quantifiable differences between cortical and cancellous bone (when imaging with an ultrasound probe in direct contact with each bone type) can potentially be used to ensure an optimal trajectory during surgery. Our results are promising for the introduction and development of photoacoustic imaging systems to overcome a wide range of longstanding challenges with spinal surgeries, including challenges with the occurrence of bone breaches due to misplaced pedicle screws.

Entities:  

Mesh:

Year:  2018        PMID: 29923832      PMCID: PMC6097631          DOI: 10.1088/1361-6560/aacdd3

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  35 in total

1.  Short-lag spatial coherence beamforming of photoacoustic images for enhanced visualization of prostate brachytherapy seeds.

Authors:  Muyinatu A Lediju Bell; Nathanael Kuo; Danny Y Song; Emad M Boctor
Journal:  Biomed Opt Express       Date:  2013-09-04       Impact factor: 3.732

2.  How accurately do novice surgeons place thoracic pedicle screws with the free hand technique?

Authors:  Ryan K Bergeson; Richard M Schwend; Tracey DeLucia; Selina R Silva; Jason E Smith; Frank R Avilucea
Journal:  Spine (Phila Pa 1976)       Date:  2008-07-01       Impact factor: 3.468

3.  Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients.

Authors:  T Laine; K Mäkitalo; D Schlenzka; K Tallroth; M Poussa; A Alho
Journal:  Eur Spine J       Date:  1997       Impact factor: 3.134

Review 4.  Navigation and Robotics in Spinal Surgery: Where Are We Now?

Authors:  Samuel C Overley; Samuel K Cho; Ankit I Mehta; Paul M Arnold
Journal:  Neurosurgery       Date:  2017-03-01       Impact factor: 4.654

Review 5.  Guided pedicle screw insertion: techniques and training.

Authors:  Amir Manbachi; Richard S C Cobbold; Howard J Ginsberg
Journal:  Spine J       Date:  2013-04-25       Impact factor: 4.166

6.  Non-invasive photo acoustic approach for human bone diagnosis.

Authors:  Ashok Kumar Thella; James Rizkalla; Ahdy Helmy; Vinay Kumar Suryadevara; Paul Salama; Maher Rizkalla
Journal:  J Orthop       Date:  2016-08-03

7.  Transurethral light delivery for prostate photoacoustic imaging.

Authors:  Muyinatu A Lediju Bell; Xiaoyu Guo; Danny Y Song; Emad M Boctor
Journal:  J Biomed Opt       Date:  2015-03       Impact factor: 3.170

8.  Localization of Transcranial Targets for Photoacoustic-Guided Endonasal Surgeries.

Authors:  Muyinatu A Lediju Bell; Anastasia K Ostrowski; Ke Li; Peter Kazanzides; Emad M Boctor
Journal:  Photoacoustics       Date:  2015-06-09

9.  Photoacoustic imaging driven by an interstitial irradiation source.

Authors:  Trevor Mitcham; Katherine Dextraze; Houra Taghavi; Marites Melancon; Richard Bouchard
Journal:  Photoacoustics       Date:  2015-03-14

10.  Comparison of Accuracy of Pedicle Screw Insertion Among 4 Guided Technologies in Spine Surgery.

Authors:  Yong Fan; Jinpeng Du; Jianan Zhang; Shichang Liu; Xukai Xue; Yunfei Huang; Jing Zhang; Dingjun Hao
Journal:  Med Sci Monit       Date:  2017-12-16
View more
  15 in total

1.  Empirical assessment of laser safety for photoacoustic-guided liver surgeries.

Authors:  Jiaqi Huang; Alycen Wiacek; Kelley M Kempski; Theron Palmer; Jessica Izzi; Sarah Beck; Muyinatu A Lediju Bell
Journal:  Biomed Opt Express       Date:  2021-02-03       Impact factor: 3.732

Review 2.  Photoacoustic-guided surgery from head to toe [Invited].

Authors:  Alycen Wiacek; Muyinatu A Lediju Bell
Journal:  Biomed Opt Express       Date:  2021-03-16       Impact factor: 3.732

Review 3.  Photoacoustic image-guided interventions.

Authors:  Madhumithra S Karthikesh; Xinmai Yang
Journal:  Exp Biol Med (Maywood)       Date:  2019-11-20

4.  Development of a Human Photoacoustic Imaging Reporter Gene Using the Clinical Dye Indocyanine Green.

Authors:  Nivin N Nyström; Lawrence C M Yip; Jeffrey J L Carson; Timothy J Scholl; John A Ronald
Journal:  Radiol Imaging Cancer       Date:  2019-11-29

Review 5.  Recent advances in aggregation-induced emission luminogens in photoacoustic imaging.

Authors:  Pei Li; Xuewen He; Yang Li; Jacky Wing Yip Lam; Ryan Tsz Kin Kwok; Cun Chuan Wang; Li Gang Xia; Ben Zhong Tang
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-03-12       Impact factor: 10.057

6.  GPU implementation of photoacoustic short-lag spatial coherence imaging for improved image-guided interventions.

Authors:  Eduardo A Gonzalez; Muyinatu A Lediju Bell
Journal:  J Biomed Opt       Date:  2020-07       Impact factor: 3.170

7.  In vivo photoacoustic imaging of major blood vessels in the pancreas and liver during surgery.

Authors:  Kelley M Kempski; Alycen Wiacek; Michelle Graham; Eduardo González; Bria Goodson; Derek Allman; Jasmin Palmer; Huayu Hou; Sarah Beck; Jin He; Muyinatu A Lediju Bell
Journal:  J Biomed Opt       Date:  2019-08       Impact factor: 3.758

8.  Photoacoustic imaging in the second near-infrared window: a review.

Authors:  Paul Kumar Upputuri; Manojit Pramanik
Journal:  J Biomed Opt       Date:  2019-04       Impact factor: 3.170

9.  In vivo photoacoustic guidance of stem cell injection and delivery for regenerative spinal cord therapies.

Authors:  Kelsey P Kubelick; Stanislav Y Emelianov
Journal:  Neurophotonics       Date:  2020-07-25       Impact factor: 3.593

10.  Photoacoustic-based visual servoing of a needle tip.

Authors:  Muyinatu A Lediju Bell; Joshua Shubert
Journal:  Sci Rep       Date:  2018-10-19       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.