Literature DB >> 18594448

How accurately do novice surgeons place thoracic pedicle screws with the free hand technique?

Ryan K Bergeson1, Richard M Schwend, Tracey DeLucia, Selina R Silva, Jason E Smith, Frank R Avilucea.   

Abstract

STUDY
DESIGN: Cadaver study.
OBJECTIVE: To evaluate with direct observation the errors made when novice resident surgeons place thoracic pedicle screws. To determine how many specimens need to be instrumented to assure an improvement in accuracy to currently published levels. SUMMARY OF BACKGROUND DATA: Thoracic pedicle screw instrumentation has been shown to provide numerous benefits in spinal deformity surgery including 3 column fixation of the spinal elements, decreased need for thoracoplasty or anterior thoracic release and decreased operative time and blood loss.
METHODS: Three orthopaedic residents inexperienced in pedicle screw placement received an introductory teaching session. Intact thoracic vertebral body specimens were harvested from 15 cadaver spines. Each vertebral body was mounted on a clear Plexiglas frame with only the posterior surface anatomy visible to the surgeon. Each resident surgeon instrumented 5 thoracic spines verbalizing all perceived pedicle wall violations as they occurred. An observer recorded the accuracy of the gearshift probe, flexible probe, tap, and screw placement. Critically perforated screws were defined as a greater than 2 mm breach of the pedicle wall.
RESULTS: Two hundred ninety-seven pedicles in 149 intact vertebral body specimens were instrumented. Eighty-five (29%) screws were not fully within the pedicle. Sixty-three (74%) were noncritical violations and 22 (26%) were critical violations. There were 18 (21%) screw violations not perceived by the surgeon to be outside the pedicle. There was a decrease in the proportion of total screw violations by the third cadaver (P < 0.001) and in critical screw violations by the fourth cadaver (P = 0.01).
CONCLUSION: Novice resident surgeons placing thoracic pedicle screws in cadavers were able to significantly improve by the fourth cadaver to accuracy levels documented in the literature. Surgeons in training shouldpractice these skills in the laboratory before proceeding to the operating room.

Entities:  

Mesh:

Year:  2008        PMID: 18594448     DOI: 10.1097/BRS.0b013e31817b61af

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  22 in total

Review 1.  The use and effectiveness of cadaveric workshops in higher surgical training: a systematic review.

Authors:  J Gilbody; A W Prasthofer; K Ho; M L Costa
Journal:  Ann R Coll Surg Engl       Date:  2011-07       Impact factor: 1.891

2.  Use of the Universal Clamp for deformity correction and as an adjunct to fusion: preliminary results in scoliosis.

Authors:  Jean-Luc Jouve; Jérôme Sales de Gauzy; Benjamin Blondel; Franck Launay; Franck Accadbled; Gérard Bollini
Journal:  J Child Orthop       Date:  2009-11-28       Impact factor: 1.548

3.  Three-dimensionally printed vertebrae with different bone densities for surgical training.

Authors:  Marco Burkhard; Philipp Fürnstahl; Mazda Farshad
Journal:  Eur Spine J       Date:  2018-12-03       Impact factor: 3.134

4.  Morphologic evaluation of the thoracic vertebrae for safe free-hand pedicle screw placement in adolescent idiopathic scoliosis: a CT-based anatomical study.

Authors:  Guanyu Cui; Kota Watanabe; Naobumi Hosogane; Takashi Tsuji; Ken Ishii; Masaya Nakamura; Yoshiaki Toyama; Kazuhiro Chiba; Lawrence G Lenke; Morio Matsumoto
Journal:  Surg Radiol Anat       Date:  2011-07-08       Impact factor: 1.246

5.  Photoacoustic imaging of a human vertebra: implications for guiding spinal fusion surgeries.

Authors:  Joshua Shubert; Muyinatu A Lediju Bell
Journal:  Phys Med Biol       Date:  2018-07-11       Impact factor: 3.609

6.  Comparison Between Gearshift And Drill Techniques For Pedicle Screw Placement By Resident Surgeons.

Authors:  Jonathan Allen; Yusuf T Akpolat; Shyam Kishan; Tim Peppers; Farbod Asgarzadie; Wayne K Cheng
Journal:  Int J Spine Surg       Date:  2015-06-11

7.  Assessing technical skill in ankle fracture surgery from the postoperative radiograph : pilot development and validation of a final product analysis core outcome set.

Authors:  Hannah K James; James Griffin; Giles T R Pattison
Journal:  Bone Jt Open       Date:  2022-06

8.  Simulation in shoulder surgery.

Authors:  Henry B Colaço; Duncan Tennent
Journal:  Shoulder Elbow       Date:  2016-09-09

9.  Use of the Universal Clamp in adolescent idiopathic scoliosis for deformity correction and as an adjunct to fusion: 2-year follow-up.

Authors:  Jérôme Sale de Gauzy; Jean-Luc Jouve; Franck Accadbled; Benjamin Blondel; Gérard Bollini
Journal:  J Child Orthop       Date:  2011-07-13       Impact factor: 1.548

10.  Accuracy of free hand pedicle screw installation in the thoracic and lumbar spine by a young surgeon: an analysis of the first consecutive 306 screws using computed tomography.

Authors:  Chang-Hyun Lee; Seung-Jae Hyun; Yongjung J Kim; Ki-Jeong Kim; Tae-Ahn Jahng; Hyun-Jib Kim
Journal:  Asian Spine J       Date:  2014-06-09
View more