Impact of dual-energy CT post-processing to differentiate venous thrombosis from iodine flux artefacts.

Jakob Weiss1, Christoph Schabel2, Ahmed E Othman1, Georg Bier3, Konstantin Nikolaou1, Fabian Bamberg1, Malte N Bongers1.   

Abstract

OBJECTIVES: To investigate the accuracy of dual-energy (DE) CT-based iodine maps (IM) and noise-optimised monoenergetic extrapolations (MEI+) at 40 keV for the detection and differentiation of venous thrombosis (VT) from iodine flux artefacts (IFA) in comparison to portal-venous phase CT (CTPV).
METHODS: Ninety-nine patients were enrolled in this study. In all patients, VT or IFA was suspected on contrast-enhanced CT and confirmed by follow-up CT or colour-coded ultrasound. All examinations were performed on a third-generation dual-source CT system in DE mode during portal-venous phase. CTPV, IM and 40-keV MEI+ were reconstructed and independently evaluated by two radiologists for the presence/absence of VT and/or IFA. Diagnostic confidence was rated on a three-point scale (3 = high confidence). Quantitative parameters were obtained by calculating contrast-to-noise ratios (CNRs), iodine content and thrombus volume. Diagnostic accuracy was assessed by calculating receiver operating characteristics (ROC) of CNR.
RESULTS: Diagnostic confidence was significantly higher for IM and MEI+ [both 3 (2-3)] compared to CTPV [2 (1-3); p ≤ 0.03]. ROC analysis revealed significantly higher AUC values and increased sensitivity for IM and MEI+ (AUC = 88%/sensitivity = 79.1% and 86%/73.1%) than for CTPV (75%/61.2%; p ≤ 0.01). Thrombus volume was significantly higher in MEI+ than in IM and CTPV (p < 0.001). CNR of thrombosis was significantly higher in IM [11.5 (8.5-14.5), p < 0.001) and MEI+ [10.9 (8.8-15.5), p < 0.001] than in CTPV [8.2 (5.8-11.4)]. Iodine quantification revealed significantly lower results in VT than in IFA [0.55 mg/ml (0.23-0.90) and 1.81 (1.60-2.12) mg/ml; p < 0.001].
CONCLUSIONS: IM and MEI+ 40 keV showed significantly higher diagnostic confidence and accuracy for the detection and differentiation of VT from IFA in comparison to CTPV. KEY POINTS: • Iodine maps and noise-optimised monoenergetic extrapolations at 40 keV increase diagnostic confidence and accuracy for the detection and differentiation of venous thrombosis from iodine flux artefacts. • Dual-energy post-processing can significantly increase contrast-to-noise ratio and the sensitivity for the diagnosis of venous thrombosisIodine load in venous thrombosis is significantly lower than in iodine flux artefacts.

Entities:  

Keywords:  Contrast media; Diagnostic imaging; Venous thrombosis

Mesh:

Substances:

Year:  2018        PMID: 29869173     DOI: 10.1007/s00330-018-5534-8

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  28 in total

1.  Evaluation of the deep venous system in patients with suspected pulmonary embolism with multi-detector CT: a prospective study in comparison to Doppler sonography.

Authors:  Philipp G C Begemann; Michael Bonacker; Jörn Kemper; Angelika E Guthoff; Kyungja E Hahn; Paul Steiner; Gerhard Adam
Journal:  J Comput Assist Tomogr       Date:  2003 May-Jun       Impact factor: 1.826

2.  Thrombectomy, lysis, or heparin treatment: concurrent therapies of deep vein thrombosis: therapy and experimental studies.

Authors:  H Stiegler; H Arbogast; S Nees; A Halder; A Grau; H Riess
Journal:  Semin Thromb Hemost       Date:  1989-07       Impact factor: 4.180

3.  Differentiation of neoplastic from bland macroscopic portal vein thrombi using dual-energy spectral CT imaging: a pilot study.

Authors:  Li Jun Qian; Jiong Zhu; Zhi Guo Zhuang; Qiang Xia; Yu Fan Cheng; Jian Ying Li; Jian Rong Xu
Journal:  Eur Radiol       Date:  2012-05-24       Impact factor: 5.315

4.  Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen.

Authors:  Moritz H Albrecht; Jesko Trommer; Julian L Wichmann; Jan-Erik Scholtz; Simon S Martin; Thomas Lehnert; Thomas J Vogl; Boris Bodelle
Journal:  Invest Radiol       Date:  2016-09       Impact factor: 6.016

Review 5.  Diagnostic management of acute deep vein thrombosis and pulmonary embolism.

Authors:  M V Huisman; F A Klok
Journal:  J Thromb Haemost       Date:  2013-03       Impact factor: 5.824

6.  High-attenuation recent thrombus of the portal vein: CT demonstration and clinical significance.

Authors:  H Mori; K Hayashi; M Uetani; Y Matsuoka; M Iwao; H Maeda
Journal:  Radiology       Date:  1987-05       Impact factor: 11.105

7.  Noise-optimized virtual monoenergetic images and iodine maps for the detection of venous thrombosis in second-generation dual-energy CT (DECT): an ex vivo phantom study.

Authors:  Malte N Bongers; Christoph Schabel; Bernhard Krauss; Ilias Tsiflikas; Dominik Ketelsen; Stefanie Mangold; Claus D Claussen; Konstantin Nikolaou; Christoph Thomas
Journal:  Eur Radiol       Date:  2014-12-21       Impact factor: 5.315

Review 8.  Advanced imaging in acute and chronic deep vein thrombosis.

Authors:  Gita Yashwantrao Karande; Sandeep S Hedgire; Yadiel Sanchez; Vinit Baliyan; Vishala Mishra; Suvranu Ganguli; Anand M Prabhakar
Journal:  Cardiovasc Diagn Ther       Date:  2016-12

9.  Incidental venous thromboembolism in ambulatory cancer patients receiving chemotherapy.

Authors:  Marcello Di Nisio; Noemi Ferrante; Michele De Tursi; Stefano Iacobelli; Franco Cuccurullo; Harry R Büller; Beatrice Feragalli; Ettore Porreca
Journal:  Thromb Haemost       Date:  2010-08-30       Impact factor: 5.249

10.  Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast.

Authors:  Moritz H Albrecht; Jan-Erik Scholtz; Kristina Hüsers; Martin Beeres; Andreas M Bucher; Moritz Kaup; Simon S Martin; Sebastian Fischer; Boris Bodelle; Ralf W Bauer; Thomas Lehnert; Thomas J Vogl; Julian L Wichmann
Journal:  Eur Radiol       Date:  2015-09-03       Impact factor: 5.315

View more
  2 in total

Review 1.  Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications.

Authors:  Tommaso D'Angelo; Giuseppe Cicero; Silvio Mazziotti; Giorgio Ascenti; Moritz H Albrecht; Simon S Martin; Ahmed E Othman; Thomas J Vogl; Julian L Wichmann
Journal:  Br J Radiol       Date:  2019-04-09       Impact factor: 3.039

2.  Diagnostic Effectiveness of Dual Source Dual Energy Computed Tomography for Benign and Malignant Thyroid Nodules.

Authors:  Tong Zhu; Kanglin Xie; Chongxiao Wang; Linkui Wang; Wei Liu; Faping Zhang
Journal:  Evid Based Complement Alternat Med       Date:  2022-08-17       Impact factor: 2.650

  2 in total