Fahad Alkhudhairy1, Abdulaziz AlKheraif2, Mustafa Naseem3, Rawaiz Khan4, Fahim Vohra5.
Abstract
OBJECTIVE: To evaluate the degree of conversion (DC) and depth (extent) of cure of four resin cements (Variolink E, Calibra, NX3 and Variolink N) using Fourier transform infrared (FTIR) and Vickers Micro hardness (MH).Entities:
Keywords: Degree of Conversion; Ivocerin; Luting cements; Micro hardness
Year: 2018 PMID: 29805389 PMCID: PMC5954360 DOI: 10.12669/pjms.342.14491
Source DB: PubMed Journal: Pak J Med Sci ISSN: 1681-715X Impact factor: 1.088
Materials used in the study.
| Product | Polymerization | Initiator | Content | Manufacturer |
|---|---|---|---|---|
| Variolink- Esthetics (LC) | Light cure | Ivocerin and thiocarbamide hydroperoxide self-curing initiator | UDMA Urethane dimethacrylate monomers, filler, initiator and stabilizers, pigments | Ivoclar-Vivadent |
| Calibra | Dual Cure | Benzoyl peroxide Camphorquinone | BISGMA resins monomer, glass fillers, coupling agent, peroxide | Dentsply Caulk |
| NX3 (LC) | Light cure | Proprietory redox initiator system | HEMA, uncured methacralayte, titanium dioxide pigments | Kerr, Canada |
| Variolink –N (high viscosity) | Dual Cure | Tertiary amine camphorquinone | BISGMA Barium glass filler, Di-methacrylates, silica, initiators, stabilers, pigments | Ivoclar-Vivadent |
Means (SD) for degree of conversion (%) values among study groups using ANOVA and Tukey multiple comparisons test.
| Cement Type | Mean | SD | SE | Variance | P-value[ |
| Calibra | 61.525A | 3.876 | 2.215 | 10.851 | <0.001 |
| Variolink-N | 44.556B | 4.336 | 2.255 | 9.882 | |
| NX-3 | 75.919C | 5.113 | 2.416 | 10.333 | |
| Variolink- E | 87.185D | 2.906 | 1.678 | 8.448 |
Dissimilar alphabets in the same column means statistical significant difference (Tukey multiple comparison test)
Showing significant difference among study groups (ANOVA).
Fig.1Degree of conversion (%) among different study groups.
Fig.2FTIR graph showing heights of aliphatic C=C peaks for Variolink Esthetic cement.
Fig.3FTIR graph showing heights of aliphatic C=C peaks for Variolink-N cement
Means (SD) for Vickers micro-hardness (VHN) values among study groups before and after ageing using ANOVA and Tukey multiple comparisons test.
| Cement Type | Control | Thermocycled | P value! | ||
|---|---|---|---|---|---|
| Mean * | SD | Mean | SD | ||
| Calibra | 37.36Aa | 1.29 | 32.75Ab | 0.34 | <0.001 |
| Variolink-N | 34.70Ba | 0.78 | 30.95Ab | 0.61 | |
| NX-3 | 44.74Ca | 0.83 | 44.05Ba | 0.28 | |
| Variolink- E | 47.71Da | 1.01 | 46.69Ba | 0.35 | |
Dissimilar capital alphabets in the same column are significantly different.
Dissimilar small alphabets in the same row are significantly different.
Fig.4Micro-Hardness values (VHN) among different study groups before and after thermocycling.