| Literature DB >> 29785976 |
Alessandra G Samelli1, Raquel F Gomes1, Tiago V Chammas1, Bárbara G Silva1, Renata R Moreira2, Ana C Fiorini3.
Abstract
INTRODUCTION: This study aimed to analyze and compare four different types of earplugs, divided into premolded plugs and foam plug models, in relation to the level of attenuation, comfort, and the size of the external acoustic meatus (EAM) in an attempt to identify how these variables influence the choice of specific hearing protection devices (HPDs).Entities:
Keywords: Attenuation; comfort; earplugs; fit test; hearing protection devices
Mesh:
Year: 2018 PMID: 29785976 PMCID: PMC5965002 DOI: 10.4103/nah.NAH_50_17
Source DB: PubMed Journal: Noise Health ISSN: 1463-1741 Impact factor: 0.867
Distribution of the measurements of the EAM volume variable by the category of the variable otometry in the right ear
| Otometry − RE |
| Mean | SD | Minimum | Median | Maximum |
|---|---|---|---|---|---|---|
| XS + S | 5 | 0.88 | 0.327 | 0.36 | 0.99 | 1.14 |
| M | 11 | 0.94 | 0.264 | 0.44 | 0.96 | 1.31 |
| L + XL | 33 | 1.18 | 0.374 | 0.61 | 1.15 | 2.44 |
RE = right ear, N = number of individuals, SD = standard deviation, XS = extra small, S = small, M = medium, L = large, XL = extra large.
Distribution of the measurements of the EAM volume variable by the category of the variable otometry in the left ear
| Otometry − LE |
| Mean | SD | Minimum | Median | Maximum |
|---|---|---|---|---|---|---|
| XS + S | 4 | 0.73 | 0.246 | 0.42 | 0.75 | 1.02 |
| M | 15 | 1.09 | 0.282 | 0.63 | 0.98 | 1.79 |
| L + XL | 30 | 1.17 | 0.391 | 0.45 | 1.19 | 2.41 |
LE = left ear, N = number of individuals, SD = standard deviation, XS = extra small, S = small, M = medium, L = large, XL = extra large.
Distribution of PAR variable measures by the type of preferred HPD and HPD evaluated
| Preferred HPD type | Rated HPD |
| Mean | SD | Minimum | Median | Maximum |
|---|---|---|---|---|---|---|---|
| Premolded | Premolded | 31 | 16.07 | 4.501 | 5 | 17 | 25 |
| Foam plug | 31 | 19.13 | 5.610 | 4 | 19 | 30 | |
| Foam plug | Premolded | 18 | 16.33 | 3.896 | 4 | 17 | 21 |
| Foam plug | 18 | 20.78 | 5.550 | 5 | 22 | 26 |
PAR = individual attenuation level, HPD = hearing protection device, N = number of individuals, SD = standard deviation.
Joint frequency distributions between the variable “Preferred HPD Type” and the BCRS variables
| Preferred HPD type | Foam plug | Premolded | Total |
| |||
|---|---|---|---|---|---|---|---|
|
|
|
| |||||
|
| % |
| % |
| % | ||
| BCRS variables | |||||||
| Pain | |||||||
| Worst | 1 | 5.56 | 2 | 6.45 | 3 | 6.12 | 0.450 |
| Neutral | 2 | 11.11 | 8 | 25.81 | 10 | 20.41 | |
| Best | 15 | 83.33 | 21 | 67.74 | 36 | 73.47 | |
| Comfort | |||||||
| Worst | 1 | 5.56 | 3 | 9.68 | 4 | 8.16 | 0.785 |
| Neutral | 6 | 33.33 | 8 | 25.81 | 14 | 28.57 | |
| Best | 11 | 61.11 | 20 | 64.52 | 31 | 63.27 | |
| Excessive pressure | |||||||
| Worst | 0 | 0.00 | 2 | 6.45 | 2 | 4.08 | 0.223 |
| Neutral | 3 | 16.67 | 10 | 32.26 | 13 | 26.53 | |
| Best | 15 | 83.3 | 19 | 61.29 | 34 | 69.39 | |
| Tolerance | |||||||
| Worst | 0 | 0.00 | 3 | 9.68 | 3 | 6.12 | 0.386 |
| Neutral | 7 | 38.89 | 10 | 32.26 | 17 | 34.69 | |
| Best | 11 | 61.11 | 18 | 58.06 | 29 | 59.18 | |
| Tightness | |||||||
| Worst | 1 | 5.56 | 3 | 9.68 | 4 | 8.16 | 0.877 |
| Neutral | 5 | 27.78 | 8 | 25.81 | 13 | 26.53 | |
| Best | 12 | 66.67 | 20 | 64.52 | 32 | 65.31 | |
| Convenience | |||||||
| Worst | 0 | 0.00 | 5 | 16.13 | 5 | 10.20 | 0.116 |
| Neutral | 9 | 50.00 | 9 | 29.03 | 18 | 36.73 | |
| Best | 9 | 50.00 | 17 | 54.84 | 26 | 53.06 | |
| Weight | |||||||
| Neutral | 2 | 11.11 | 1 | 3.23 | 3 | 6.12 | 0.267 |
| Best | 16 | 88.89 | 30 | 96.77 | 46 | 93.88 | |
| Embarrassment | |||||||
| Worst | 0 | 0.00 | 4 | 12.90 | 4 | 8.16 | 0.264 |
| Neutral | 2 | 11.11 | 4 | 12.90 | 6 | 12.24 | |
| Best | 16 | 88.89 | 23 | 74.19 | 39 | 79.59 | |
| Rigidity | |||||||
| Worst | 0 | 0.00 | 1 | 3.23 | 1 | 2.04 | 0.700 |
| Neutral | 5 | 27.78 | 7 | 22.58 | 12 | 24.49 | |
| Best | 13 | 72.22 | 23 | 74.19 | 36 | 73.47 | |
| Heat | |||||||
| Worst | 2 | 11.11 | 2 | 6.45 | 4 | 8.16 | 0.476 |
| Neutral | 5 | 27.78 | 5 | 16.13 | 10 | 20.41 | |
| Best | 11 | 61.11 | 24 | 77.42 | 35 | 71.43 | |
| Roughness | |||||||
| Worst | 0 | 0.00 | 1 | 3.23 | 1 | 2.04 | 0.486 |
| Neutral | 5 | 27.78 | 5 | 16.13 | 10 | 20.41 | |
| Best | 13 | 72.22 | 25 | 80.65 | 38 | 77.55 | |
| Insulation | |||||||
| Worst | 4 | 22.22 | 6 | 19.35 | 10 | 20.41 | 0.112 |
| Neutral | 3 | 16.67 | 14 | 45.16 | 17 | 34.69 | |
| Best | 11 | 61.11 | 11 | 35.48 | 22 | 44.90 | |
| Placement | |||||||
| Worst | 4 | 22.22 | 1 | 3.23 | 5 | 10.20 | 0.009* |
| Neutral | 7 | 38.89 | 5 | 16.13 | 12 | 24.49 | |
| Best | 7 | 38.89 | 25 | 80.65 | 32 | 65.31 | |
| Complexity | |||||||
| Worst | 1 | 5.55 | 0 | 0.00 | 1 | 2.04 | 0.016* |
| Neutral | 7 | 38.89 | 3 | 9.68 | 10 | 20.41 | |
| Best | 10 | 55.56 | 28 | 90.32 | 38 | 77.55 | |
| Head movement | |||||||
| Worst | 0 | 0.00 | 1 | 2.04 | 1 | 2.04 | 0.642 |
| Neutral | 2 | 11.11 | 2 | 6.45 | 4 | 8.16 | |
| Best | 16 | 88.89 | 28 | 90.32 | 44 | 89.80 | |
| Occlusion effect | |||||||
| Worst | 4 | 22.22 | 1 | 3.23 | 5 | 10.20 | 0.083* |
| Neutral | 4 | 22.22 | 12 | 38.71 | 16 | 32.65 | |
| Best | 10 | 55.56 | 18 | 58.06 | 28 | 57.14 | |
HPD = hearing protection device, BCRS = Bipolar Comfort Rating Scale. *P < 0.10.
Odds ratios and 95% confidence intervals for odds ratios relative to logistic regression parameters
| Variable | Odds ratios | CI (95%) for the odds ratios | |
|---|---|---|---|
|
| |||
| Lower limit | Upper limit | ||
| Placement | |||
| Neutral × worst | 2.59 | 0.19 | 34.94 |
| Best × worst | 22.84 | 1.72 | 303.59 |
| Best × neutral | 8.81 | 1.79 | 43.42 |
| Occlusion effect | |||
| Neutral × worst | 33.06 | 2.04 | 535.11 |
| Best × worst | 14.47 | 1.17 | 179.08 |
| Best × neutral | 0.44 | 0.08 | 2.28 |
CI = confidence interval.