| Literature DB >> 29785503 |
Zainie Aboo Bakkar1, Jonathan Fulford2, Phillip E Gates2, Sarah R Jackman1, Andrew M Jones1, Bert Bond1, Joanna L Bowtell3.
Abstract
PURPOSE: Repeated cycles of endothelial ischemia-reperfusion injury and the resulting respiratory burst contribute to the irreversible pathophysiology of vascular diseases, and yet, the effects of ischemia reperfusion on vascular function, oxidative stress, and nitric oxide (NO) bioavailability have not been assessed simultaneously. Therefore, this study sought to examine the effects of prolonged forearm occlusion and subsequent reperfusion on NO-dependent brachial artery endothelial function.Entities:
Keywords: Endothelial function; Forearm occlusion; Nitrite/nitrate; Peroxiredoxin-2
Mesh:
Substances:
Year: 2018 PMID: 29785503 PMCID: PMC6060779 DOI: 10.1007/s00421-018-3886-z
Source DB: PubMed Journal: Eur J Appl Physiol ISSN: 1439-6319 Impact factor: 3.078
Participant characteristics
| Age, year | 53 ± 1 |
| Height, cm | 179 ± 1 |
| Weight, kg | 90.6 ± 3.5 |
| Body mass index, kg/m2 | 28.1 ± 0.1 |
| Heart rate, beat/min | 65 ± 1 |
| Systolic blood pressure, mmHg | 139 ± 5 |
| Diastolic blood pressure, mmHg | 86 ± 3 |
Values are expressed as mean ± SE
Fig. 1Brachial artery flow-mediated dilatation (FMD) and venous blood collection before and after prolonged occlusion protocol to induce transient ischemic reperfusion injury (IRI). Arrows represent FMD measurements and collection of blood samples
Fig. 2Brachial artery flow-mediated dilatation (FMD) measured before and after prolonged occlusion. *p < 0.05 vs baseline
Brachial artery flow-mediated dilatation measures before (pre) and after (15, 30, and 45 min) prolonged occlusion
| Time | Pre diameter (mm) | Peak diameter (mm) | SR AUC | FMD:SR AUC (AU) |
|---|---|---|---|---|
| Baseline | 3.80 ± 0.13 | 4.04 ± 0.13 | 694 ± 82 | 0.98 ± 0.09 |
| 15-min post | 3.88 ± 0.13* | 3.99 ± 0.14* | 603 ± 55 | 0.49 ± 0.06* |
| 30-min post | 3.83 ± 0.13 | 3.98 ± 0.14* | 622 ± 49 | 0.65 ± 0.07* |
| 45-min post | 3.80 ± 0.13 | 4.00 ± 0.13 | 684 ± 61 | 0.79 ± 0.08 |
Data are expressed as means ± SE
FMD flow-mediated dilatation, SR AUC shear rate area under the curve
*p < 0.05 vs baseline
Fig. 3Plasma nitrate (a) and nitrite (b) concentration measured before and after prolonged occlusion. *p < 0.05 vs baseline
Fig. 4Plasma protein carbonyl concentration ([PC]) (a), peroxiredoxin 2 concentration ([Prx2]) (b) and catalase (CAT) activity (c) measured before and after prolonged occlusion. *p < 0.05 vs baseline