Literature DB >> 29779276

[Fabrication and accuracy research on 3D printing dental model based on cone beam computed tomography digital modeling].

Hui-Rong Zhang1, Le-Feng Yin1, Yan-Li Liu1, Li-Yi Yan1, Ning Wang1, Gang Liu2, Xiao-Li An1, Bin Liu1.   

Abstract

OBJECTIVE: The aim of this study is to build a digital dental model with cone beam computed tomography (CBCT), to fabricate a virtual model via 3D printing, and to determine the accuracy of 3D printing dental model by comparing the result with a traditional dental cast.
METHODS: CBCT of orthodontic patients was obtained to build a digital dental model by using Mimics 10.01 and Geomagic studio software. The 3D virtual models were fabricated via fused deposition modeling technique (FDM). The 3D virtual models were compared with the traditional cast models by using a Vernier caliper. The measurements used for comparison included the width of each tooth, the length and width of the maxillary and mandibular arches, and the length of the posterior dental crest.
RESULTS: 3D printing models had higher accuracy compared with the traditional cast models. The results of the paired t-test of all data showed that no statistically significant difference was observed between the two groups (P>0.05).
CONCLUSIONS: Dental digital models built with CBCT realize the digital storage of patients' dental condition. The virtual dental model fabricated via 3D printing avoids traditional impression and simplifies the clinical examination process. The 3D printing dental models produced via FDM show a high degree of accuracy. Thus, these models are appropriate for clinical practice.

Entities:  

Keywords:  3D printing technique; cone beam computed tomography; digital dental model

Mesh:

Year:  2018        PMID: 29779276      PMCID: PMC7030340          DOI: 10.7518/hxkq.2018.02.008

Source DB:  PubMed          Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi        ISSN: 1000-1182


  16 in total

1.  A 3D computer-aided design system applied to diagnosis and treatment planning in orthodontics and orthognathic surgery.

Authors:  N Motohashi; T Kuroda
Journal:  Eur J Orthod       Date:  1999-06       Impact factor: 3.075

2.  Complete 3-D reconstruction of dental cast shape using perceptual grouping.

Authors:  Y Hirogaki; T Sohmura; H Satoh; J Takahashi; K Takada
Journal:  IEEE Trans Med Imaging       Date:  2001-10       Impact factor: 10.048

3.  Comparison of measurements made on digital and plaster models.

Authors:  Margherita Santoro; Scott Galkin; Monica Teredesai; Olivier F Nicolay; Thomas J Cangialosi
Journal:  Am J Orthod Dentofacial Orthop       Date:  2003-07       Impact factor: 2.650

4.  The accuracy and reliability of measurements made on computer-based digital models.

Authors:  Meredith L Quimby; Katherine W L Vig; Robert G Rashid; Allen R Firestone
Journal:  Angle Orthod       Date:  2004-06       Impact factor: 2.079

5.  A new system for scanning, measuring and analyzing dental casts based on a 3D holographic sensor.

Authors:  M Redlich; T Weinstock; Y Abed; R Schneor; Y Holdstein; A Fischer
Journal:  Orthod Craniofac Res       Date:  2008-05       Impact factor: 1.826

6.  Reproducibility and accuracy of linear measurements on dental models derived from cone-beam computed tomography compared with digital dental casts.

Authors:  Olivier de Waard; Frits Andreas Rangel; Piotr Stanislaw Fudalej; Ewald Maria Bronkhorst; Anne Marie Kuijpers-Jagtman; Karel Hero Breuning
Journal:  Am J Orthod Dentofacial Orthop       Date:  2014-09       Impact factor: 2.650

7.  Integration accuracy of laser-scanned dental models into maxillofacial cone beam computed tomography images of different voxel sizes with different segmentation threshold settings.

Authors:  Niansong Ye; Hu Long; Junjie Xue; Sheng Wang; Xin Yang; Wenli Lai
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2014-03-12

8.  Evaluation of CBCT digital models and traditional models using the Little's Index.

Authors:  Chung How Kau; Jay Littlefield; Neal Rainy; Jennifer T Nguyen; Ben Creed
Journal:  Angle Orthod       Date:  2010-05       Impact factor: 2.079

9.  Technique comparison for efficient orthodontic tooth measurements using digital models.

Authors:  Heather M I Horton; James R Miller; Philippe R Gaillard; Brent E Larson
Journal:  Angle Orthod       Date:  2010-03       Impact factor: 2.079

10.  Validity of Intraoral Scans Compared with Plaster Models: An In-Vivo Comparison of Dental Measurements and 3D Surface Analysis.

Authors:  Fan Zhang; Kyung-Jin Suh; Kyung-Min Lee
Journal:  PLoS One       Date:  2016-06-15       Impact factor: 3.240

View more
  2 in total

1.  Accuracy of maxillofacial prototypes fabricated by different 3-dimensional printing technologies using multi-slice and cone-beam computed tomography.

Authors:  Faezeh Yousefi; Abbas Shokri; Maryam Farhadian; Fariborz Vafaei; Fereshte Forutan
Journal:  Imaging Sci Dent       Date:  2021-01-28

2.  Three-dimensional inlay-guided endodontics applied in variant root canals: A case report and review of literature.

Authors:  Yin-Qiu Yan; Hui-Li Wang; Yu Liu; Tai-Jing Zheng; Ya-Ping Tang; Rui Liu
Journal:  World J Clin Cases       Date:  2021-12-26       Impact factor: 1.337

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.