Literature DB >> 29761338

[Journey of the S‑ICD to first-line therapy].

Elif Kaya1, Reza Wakili2, Tienush Rassaf2.   

Abstract

The subcutaneous implantable cardioverter-defibrillator (S-ICD®, Boston Scientific, Marlborough, MA, USA, previously Cameron Health, San Clemente, CA, USA) represents an important milestone in ICD therapy for prevention of sudden cardiac death (SCD). Since the introduction of the S‑ICD in 2010, the device has undergone further development. Based on the unique feature of an entirely extracardiac implantation, the S‑ICD is able to reduce the common perioperative and long-term complications of the usual endovascular implanted ICD systems. Especially for patients with a complex anatomy and no option of an endovascular lead implantation, the S‑ICD offers a potential alternative. Regarding the initial uncertainty if this innovative ICD approach is actually reliable in detecting and terminating ventricular arrhythmias has been resolved by multiple clinical studies and trials providing evidence for an effective treatment. Based on the obvious advantages compared to conventional ICD systems, the question arises if the S‑ICD should actually be the first choice in the majority of all primary prevention patients in the future. Furthermore, recent data from large registries show that S‑ICD indications are also expanding in secondary prevention patients. As a consequence the S‑ICD was listed in the 2015 ESC guidelines as an alternative therapeutic option with a class IIa recommendation in patients with an ICD indication not requiring pacing for bradycardia, cardiac resynchronization therapy or anti-tachycardia pacing (ATP). In addition, the American Heart Association guidelines refer to class I recommendation for patients with a complex anatomy and venous access problems or at a high risk for infections who need ICD therapy. Limitations with respect to the not available pacing option of S‑ICD might be also overcome by a potential combination with a leadless pacemaker in the near future. This article provides an overview of recent developments of the S‑ICD and reviews the most recent literature and ongoing studies.

Entities:  

Keywords:  Efficacy; Indication; Research and development; Subcutaneous defibrillator; Sudden cardiac death

Mesh:

Year:  2018        PMID: 29761338     DOI: 10.1007/s00399-018-0559-x

Source DB:  PubMed          Journal:  Herzschrittmacherther Elektrophysiol        ISSN: 0938-7412


  13 in total

1.  Randomized comparison of antiarrhythmic drug therapy with implantable defibrillators in patients resuscitated from cardiac arrest : the Cardiac Arrest Study Hamburg (CASH).

Authors:  K H Kuck; R Cappato; J Siebels; R Rüppel
Journal:  Circulation       Date:  2000-08-15       Impact factor: 29.690

2.  2015 ESC Guidelines for the Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death.

Authors:  Silvia G Priori; Carina Blomström-Lundqvist; Andrea Mazzanti; Nico Blom; Martin Borggrefe; John Camm; Perry Mark Elliott; Donna Fitzsimons; Robert Hatala; Gerhard Hindricks; Paulus Kirchhof; Keld Kjeldsen; Karl-Heinz Kuck; Antonio Hernandez-Madrid; Nikolaos Nikolaou; Tone M Norekvål; Christian Spaulding; Dirk J Van Veldhuisen
Journal:  Rev Esp Cardiol (Engl Ed)       Date:  2016-02

Review 3.  ACC/AHA/HRS 2008 guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: executive summary.

Authors:  Andrew E Epstein; John P Dimarco; Kenneth A Ellenbogen; N A Mark Estes; Roger A Freedman; Leonard S Gettes; A Marc Gillinov; Gabriel Gregoratos; Stephen C Hammill; David L Hayes; Mark A Hlatky; L Kristin Newby; Richard L Page; Mark H Schoenfeld; Michael J Silka; Lynne Warner Stevenson; Michael O Sweeney
Journal:  Heart Rhythm       Date:  2008-05-19       Impact factor: 6.343

4.  Safety and efficacy of a totally subcutaneous implantable-cardioverter defibrillator.

Authors:  Raul Weiss; Bradley P Knight; Michael R Gold; Angel R Leon; John M Herre; Margaret Hood; Mayer Rashtian; Mark Kremers; Ian Crozier; Kerry L Lee; Warren Smith; Martin C Burke
Journal:  Circulation       Date:  2013-08-27       Impact factor: 29.690

5.  Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction.

Authors:  Arthur J Moss; Wojciech Zareba; W Jackson Hall; Helmut Klein; David J Wilber; David S Cannom; James P Daubert; Steven L Higgins; Mary W Brown; Mark L Andrews
Journal:  N Engl J Med       Date:  2002-03-19       Impact factor: 91.245

6.  Trends and In-Hospital Outcomes Associated With Adoption of the Subcutaneous Implantable Cardioverter Defibrillator in the United States.

Authors:  Daniel J Friedman; Craig S Parzynski; Paul D Varosy; Jordan M Prutkin; Kristen K Patton; Ali Mithani; Andrea M Russo; Jeptha P Curtis; Sana M Al-Khatib
Journal:  JAMA Cardiol       Date:  2016-11-01       Impact factor: 14.676

Review 7.  2017 AHA/ACC/HRS Guideline for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death: Executive Summary: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society.

Authors:  Sana M Al-Khatib; William G Stevenson; Michael J Ackerman; William J Bryant; David J Callans; Anne B Curtis; Barbara J Deal; Timm Dickfeld; Michael E Field; Gregg C Fonarow; Anne M Gillis; Christopher B Granger; Stephen C Hammill; Mark A Hlatky; José A Joglar; G Neal Kay; Daniel D Matlock; Robert J Myerburg; Richard L Page
Journal:  J Am Coll Cardiol       Date:  2017-10-30       Impact factor: 24.094

8.  Implant and Midterm Outcomes of the Subcutaneous Implantable Cardioverter-Defibrillator Registry: The EFFORTLESS Study.

Authors:  Lucas Boersma; Craig Barr; Reinoud Knops; Dominic Theuns; Lars Eckardt; Petr Neuzil; Marcoen Scholten; Margaret Hood; Juergen Kuschyk; Paul Jones; Elizabeth Duffy; Michael Husby; Kenneth Stein; Pier D Lambiase
Journal:  J Am Coll Cardiol       Date:  2017-08-15       Impact factor: 24.094

9.  Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years.

Authors:  Thomas Kleemann; Torsten Becker; Klaus Doenges; Margit Vater; Jochen Senges; Steffen Schneider; Werner Saggau; Udo Weisse; Karlheinz Seidl
Journal:  Circulation       Date:  2007-04-30       Impact factor: 29.690

10.  Two-incision technique for implantation of the subcutaneous implantable cardioverter-defibrillator.

Authors:  Reinoud E Knops; Louise R A Olde Nordkamp; Joris R de Groot; Arthur A M Wilde
Journal:  Heart Rhythm       Date:  2013-05-21       Impact factor: 6.343

View more
  1 in total

1.  Use of pulsed electron avalanche knife (PEAK) PlasmaBlade™ in patients undergoing implantation of subcutaneous implantable cardioverter-defibrillator.

Authors:  Elif Kaya; Johannes Siebermair; Obayda Azizy; Dobromir Dobrev; Tienush Rassaf; Reza Wakili
Journal:  Int J Cardiol Heart Vasc       Date:  2019-07-05
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.