Literature DB >> 29734479

Task-based design of a synthetic-collimator SPECT system used for small animal imaging.

Alexander Lin1, Matthew A Kupinski1, Todd E Peterson2, Sepideh Shokouhi2, Lindsay C Johnson3.   

Abstract

PURPOSE: In traditional multipinhole SPECT systems, image multiplexing - the overlapping of pinhole projection images - may occur on the detector, which can inhibit quality image reconstructions due to photon-origin uncertainty. One proposed system to mitigate the effects of multiplexing is the synthetic-collimator SPECT system. In this system, two detectors, a silicon detector and a germanium detector, are placed at different distances behind the multipinhole aperture, allowing for image detection to occur at different magnifications and photon energies, resulting in higher overall sensitivity while maintaining high resolution. The unwanted effects of multiplexing are reduced by utilizing the additional data collected from the front silicon detector. However, determining optimal system configurations for a given imaging task requires efficient parsing of the complex parameter space, to understand how pinhole spacings and the two detector distances influence system performance.
METHODS: In our simulation studies, we use the ensemble mean-squared error of the Wiener estimator (EMSEW ) as the figure of merit to determine optimum system parameters for the task of estimating the uptake of an 123 I-labeled radiotracer in three different regions of a computer-generated mouse brain phantom. The segmented phantom map is constructed by using data from the MRM NeAt database and allows for the reduction in dimensionality of the system matrix which improves the computational efficiency of scanning the system's parameter space. To contextualize our results, the Wiener estimator is also compared against a region of interest estimator using maximum-likelihood reconstructed data.
RESULTS: Our results show that the synthetic-collimator SPECT system outperforms traditional multipinhole SPECT systems in this estimation task. We also find that image multiplexing plays an important role in the system design of the synthetic-collimator SPECT system, with optimal germanium detector distances occurring at maxima in the derivative of the percent multiplexing function. Furthermore, we report that improved task performance can be achieved by using an adaptive system design in which the germanium detector distance may vary with projection angle. Finally, in our comparative study, we find that the Wiener estimator outperforms the conventional region of interest estimator.
CONCLUSIONS: Our work demonstrates how this optimization method has the potential to quickly and efficiently explore vast parameter spaces, providing insight into the behavior of competing factors, which are otherwise very difficult to calculate and study using other existing means.
© 2018 American Association of Physicists in Medicine.

Entities:  

Keywords:  SPECT; imaging theory; model observers; small animal SPECT; small animal imaging

Mesh:

Year:  2018        PMID: 29734479      PMCID: PMC6041187          DOI: 10.1002/mp.12952

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

1.  FastSPECT II: A Second-Generation High-Resolution Dynamic SPECT Imager.

Authors:  Lars R Furenlid; Donald W Wilson; Yi-Chun Chen; Hyunki Kim; Philip J Pietraski; Michael J Crawford; Harrison H Barrett
Journal:  IEEE Trans Nucl Sci       Date:  2004-06       Impact factor: 1.679

2.  Pinhole SPECT imaging of dopamine transporters correlates with dopamine transporter immunohistochemical analysis in the MPTP mouse model of Parkinson's disease.

Authors:  Gerda Andringa; Benjamin Drukarch; John G J M Bol; Kora de Bruin; Karolina Sorman; Jan B A Habraken; Jan Booij
Journal:  Neuroimage       Date:  2005-07-15       Impact factor: 6.556

3.  Maximum likelihood reconstruction for emission tomography.

Authors:  L A Shepp; Y Vardi
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

4.  Multi-energy, single-isotope imaging using stacked detectors.

Authors:  B S McDonald; S Shokouhi; H H Barrett; T E Peterson
Journal:  Nucl Instrum Methods Phys Res A       Date:  2007-08-21       Impact factor: 1.455

5.  Quantification of the Multiplexing Effects in Multi-Pinhole Small Animal SPECT: A Simulation Study.

Authors:  Greta S P Mok; Yuchuan Wang; Benjamin M W Tsui
Journal:  IEEE Trans Nucl Sci       Date:  2009       Impact factor: 1.679

6.  Evaluation of neurotoxicity of TIQ and MPTP and of parkinsonism-preventing effect of 1-MeTIQ by in vivo measurement of pre-synaptic dopamine transporters and post-synaptic dopamine D(2) receptors in the mouse striatum.

Authors:  K Ishiwata; Y Koyanagi; K Abe; K Kawamura; K Taguchi; T Saitoh; J Toda; M Senda; T Sano
Journal:  J Neurochem       Date:  2001-11       Impact factor: 5.372

7.  A three-dimensional digital atlas database of the adult C57BL/6J mouse brain by magnetic resonance microscopy.

Authors:  Y Ma; P R Hof; S C Grant; S J Blackband; R Bennett; L Slatest; M D McGuigan; H Benveniste
Journal:  Neuroscience       Date:  2005-09-13       Impact factor: 3.590

8.  Comparison of intravenous and intraperitoneal [123I]IBZM injection for dopamine D2 receptor imaging in mice.

Authors:  Philipp T Meyer; Dagmar Salber; Johannes Schiefer; Markus Cremer; Wolfgang M Schaefer; Christoph M Kosinski; Karl-Josef Langen
Journal:  Nucl Med Biol       Date:  2008-07       Impact factor: 2.408

9.  Reducing multiplexing artifacts in multi-pinhole SPECT with a stacked silicon-germanium system: a simulation study.

Authors:  Lindsay C Johnson; Sepideh Shokouhi; Todd E Peterson
Journal:  IEEE Trans Med Imaging       Date:  2014-07-17       Impact factor: 10.048

Review 10.  D2-receptor imaging with [123I]IBZM and single photon emission tomography in psychiatry: a survey of current status.

Authors:  R Schlösser; S Schlegel
Journal:  J Neural Transm Gen Sect       Date:  1995
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.