Literature DB >> 2971446

In vitro balloon dilatation of the banded pulmonary artery.

B Smevik1, H Lindberg, S Tjønneland, P G Bjørnstad, S J Sørland, A Foerster.   

Abstract

The pulmonary artery of unfixated human heart-lung specimens was banded by placing a Dacron tape around the artery and securing the tape with a 5.0 Prolene suture at selected circumferences. The banding was successfully dilated with a balloon catheter in 24 instances. The mean pressure necessary to burst the suture securing the tape was 2.4 atmospheres.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 2971446     DOI: 10.1007/bf02577108

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  4 in total

1.  The treatment of certain congenital malformations of the heart by the creation of pulmonic stenosis to reduce pulmonary hypertension and excessive pulmonary blood flow; a preliminary report.

Authors:  W H MULLER; J F DANIMANN
Journal:  Surg Gynecol Obstet       Date:  1952-08

Review 2.  Interventional techniques in congenital heart disease.

Authors:  S E Mitchell; J S Kan; R I White
Journal:  Semin Roentgenol       Date:  1985-07       Impact factor: 0.800

3.  A method of banding the pulmonary artery for large isolated ventricular septal defect with and without transposition of the great arteries.

Authors:  G A Trusler; W T Mustard
Journal:  Ann Thorac Surg       Date:  1972-04       Impact factor: 4.330

4.  Pulmonary artery banding.

Authors:  R A Albus; G A Trusler; T Izukawa; W G Williams
Journal:  J Thorac Cardiovasc Surg       Date:  1984-11       Impact factor: 5.209

  4 in total
  4 in total

1.  Balloon dilatation of pulmonary artery band.

Authors:  P G Bjørnstad
Journal:  Pediatr Cardiol       Date:  2000 Jul-Aug       Impact factor: 1.655

2.  Balloon debanding of the pulmonary artery.

Authors:  P G Bjørnstad; H L Lindberg; B Smevik; R Rian; S J Sørland; S Tjønneland
Journal:  Cardiovasc Intervent Radiol       Date:  1990 Oct-Nov       Impact factor: 2.740

3.  Balloon dilatation of pulmonary artery banding in dogs: an experimental study.

Authors:  H Lindberg; B Smevik; P G Bjørnstad; R Rian; A Foerster; S Tjønneland; S Sørland; S Sponheim
Journal:  Cardiovasc Intervent Radiol       Date:  1988-06       Impact factor: 2.740

4.  Catheter balloon adjustment of the pulmonary artery band: feasibility and safety.

Authors:  Howaida El-Said; Rabih Hamzeh; John Lamberti; John Moore
Journal:  Pediatr Cardiol       Date:  2010-10-31       Impact factor: 1.655

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.