Balloon dilatation of pulmonary artery banding in dogs: an experimental study.

H Lindberg1, B Smevik, P G Bjørnstad, R Rian, A Foerster, S Tjønneland, S Sørland, S Sponheim.   

Abstract

The technique at our institution for banding of the pulmonary artery (PA) makes debanding by balloon dilatation theoretically possible. Previously we tested this hypothesis in an in vitro study (see previous article in this issue). This study describes balloon dilatation in dogs. Eight Labrador Retriever dogs had a PA band placed early in life, and when their body weight had doubled, they were restudied and debanded by balloon dilatation or surgical removal. One dog died of a virus infection before debanding and was excluded from the study. Five of the dogs (groups 1 and 2) underwent balloon dilatation with satisfactory relief of the gradient across the PA band. Two dogs (group 3) underwent surgical debanding without a plastic procedure on the PA, and this also produced satisfactory relief of the gradient. All dogs in group 2 and 1 dog in group 3 were studied 3 months later, and 1 dog in group 2 was also studied 6 months after the debanding procedure. The systolic pressure gradient fell from a mean of 54 to 18 mm Hg after the debanding procedure. There was no difference in the gradient after debanding in the balloon group compared to the surgical group.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 2971445     DOI: 10.1007/bf02577107

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  10 in total

1.  The treatment of certain congenital malformations of the heart by the creation of pulmonic stenosis to reduce pulmonary hypertension and excessive pulmonary blood flow; a preliminary report.

Authors:  W H MULLER; J F DANIMANN
Journal:  Surg Gynecol Obstet       Date:  1952-08

2.  The development of a prosthesis for banding of an artery capable of staged dilatation by intraluminal balloon dilator: an experimental investigation.

Authors:  D J Vince; G Culham; G Taylor
Journal:  J Thorac Cardiovasc Surg       Date:  1987-04       Impact factor: 5.209

3.  Sex difference in rates of spontaneous closure in ventricular septal defect.

Authors: 
Journal:  J Pediatr       Date:  1979-08       Impact factor: 4.406

4.  Diminution and closure of large ventricular septal defects after pulmonary artery banding.

Authors:  Z G Mesko; J E Jones; A S Nadas
Journal:  Circulation       Date:  1973-10       Impact factor: 29.690

5.  A method of banding the pulmonary artery for large isolated ventricular septal defect with and without transposition of the great arteries.

Authors:  G A Trusler; W T Mustard
Journal:  Ann Thorac Surg       Date:  1972-04       Impact factor: 4.330

6.  In vitro balloon dilatation of the banded pulmonary artery.

Authors:  B Smevik; H Lindberg; S Tjønneland; P G Bjørnstad; S J Sørland; A Foerster
Journal:  Cardiovasc Intervent Radiol       Date:  1988-06       Impact factor: 2.740

7.  Preparation of pulmonary artery banding tapes.

Authors:  S A Ridgeway; J V Villamater; G A Trusler
Journal:  J Thorac Cardiovasc Surg       Date:  1984-11       Impact factor: 5.209

8.  Apparent sex difference in spontaneous closure of ventricular septal defect.

Authors:  M A Farina; E B Hook
Journal:  J Pediatr       Date:  1978-12       Impact factor: 4.406

9.  Morphologic changes in the pulmonary arteries after percutaneous balloon angioplasty for pulmonary arterial stenosis.

Authors:  B S Edwards; R V Lucas; J E Lock; J E Edwards
Journal:  Circulation       Date:  1985-02       Impact factor: 29.690

10.  Pulmonary artery banding.

Authors:  R A Albus; G A Trusler; T Izukawa; W G Williams
Journal:  J Thorac Cardiovasc Surg       Date:  1984-11       Impact factor: 5.209

  10 in total
  4 in total

1.  Balloon dilatation of pulmonary artery band.

Authors:  P G Bjørnstad
Journal:  Pediatr Cardiol       Date:  2000 Jul-Aug       Impact factor: 1.655

2.  Balloon debanding of the pulmonary artery.

Authors:  P G Bjørnstad; H L Lindberg; B Smevik; R Rian; S J Sørland; S Tjønneland
Journal:  Cardiovasc Intervent Radiol       Date:  1990 Oct-Nov       Impact factor: 2.740

3.  Vascular histopathologic reaction to pulmonary artery banding in an in vivo growing porcine model.

Authors:  Lukáš Nedorost; Hideki Uemura; Anke Furck; Imran Saeed; Zdenek Slavik; Jiří Kobr; Zbyněk Tonar
Journal:  Pediatr Cardiol       Date:  2013-04-17       Impact factor: 1.655

4.  Catheter balloon adjustment of the pulmonary artery band: feasibility and safety.

Authors:  Howaida El-Said; Rabih Hamzeh; John Lamberti; John Moore
Journal:  Pediatr Cardiol       Date:  2010-10-31       Impact factor: 1.655

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.