Literature DB >> 2124168

Balloon debanding of the pulmonary artery.

P G Bjørnstad1, H L Lindberg, B Smevik, R Rian, S J Sørland, S Tjønneland.   

Abstract

Clinical balloon debanding of the pulmonary artery is reported in two patients, 6 months and 4 years of age. The band was made of Dacron, and was closed with one single polypropylene suture. This suture was subsequently ruptured with a balloon inflated within the pulmonary artery at the site of the band. Balloon debanding relieved the gradient almost completely in the two patients. No problems occurred during the procedure. In the future this may prove to be an efficient and reliable way to remove the effect of a pulmonary artery banding.

Entities:  

Mesh:

Year:  1990        PMID: 2124168     DOI: 10.1007/bf02578630

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  8 in total

1.  The treatment of certain congenital malformations of the heart by the creation of pulmonic stenosis to reduce pulmonary hypertension and excessive pulmonary blood flow; a preliminary report.

Authors:  W H MULLER; J F DANIMANN
Journal:  Surg Gynecol Obstet       Date:  1952-08

Review 2.  Recent advances in congenital cardiac surgery.

Authors:  W I Norwood; J D Pigott
Journal:  Clin Perinatol       Date:  1988-09       Impact factor: 3.430

3.  The development of a prosthesis for banding of an artery capable of staged dilatation by intraluminal balloon dilator: an experimental investigation.

Authors:  D J Vince; G Culham; G Taylor
Journal:  J Thorac Cardiovasc Surg       Date:  1987-04       Impact factor: 5.209

4.  A method of banding the pulmonary artery for large isolated ventricular septal defect with and without transposition of the great arteries.

Authors:  G A Trusler; W T Mustard
Journal:  Ann Thorac Surg       Date:  1972-04       Impact factor: 4.330

5.  In vitro balloon dilatation of the banded pulmonary artery.

Authors:  B Smevik; H Lindberg; S Tjønneland; P G Bjørnstad; S J Sørland; A Foerster
Journal:  Cardiovasc Intervent Radiol       Date:  1988-06       Impact factor: 2.740

6.  Pulmonary artery banding: analysis of a 25-year experience.

Authors:  M D Horowitz; W S Culpepper; L C Williams; K Sundgaard-Riise; J L Ochsner
Journal:  Ann Thorac Surg       Date:  1989-09       Impact factor: 4.330

7.  Pulmonary artery banding revisited.

Authors:  I L Kron; S P Nolan; T L Flanagan; H P Gutgesell; W H Muller
Journal:  Ann Surg       Date:  1989-05       Impact factor: 12.969

8.  Balloon dilatation of pulmonary artery banding in dogs: an experimental study.

Authors:  H Lindberg; B Smevik; P G Bjørnstad; R Rian; A Foerster; S Tjønneland; S Sørland; S Sponheim
Journal:  Cardiovasc Intervent Radiol       Date:  1988-06       Impact factor: 2.740

  8 in total
  3 in total

1.  Balloon dilatation of pulmonary artery band.

Authors:  P G Bjørnstad
Journal:  Pediatr Cardiol       Date:  2000 Jul-Aug       Impact factor: 1.655

2.  Percutaneous pulmonary debanding for an infant complicated by spontaneously closing muscular ventricular septal defect: A case report and in vitro study.

Authors:  Atsushi Terazawa; Takanari Fujii; Takeshi Sasaki; Dai Asada; Suguru Tarui; Yoshinori Miyahara; Kozo Ishino; Takashi Soga; Hideshi Tomita
Journal:  J Cardiol Cases       Date:  2017-11-06

3.  Catheter balloon adjustment of the pulmonary artery band: feasibility and safety.

Authors:  Howaida El-Said; Rabih Hamzeh; John Lamberti; John Moore
Journal:  Pediatr Cardiol       Date:  2010-10-31       Impact factor: 1.655

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.