BACKGROUND: Cardiology interventions in peripheral hospitals is a challenging task where cardiologist have to fight against time and limited resources. Most of the sudden cardiac deaths occur due to arrhythmia and heart blocks/sinus node dysfunction. Our study is a single peripheral center experience of cardiac devices implantation using a 'C' Arm. The aim of this study was to post procedural complications of cardiac implants done in aresource limited setting under 'C' arm.
METHODS: This study is done at a peripheral cardiology center with no cardiac catheterization laboratory (CCL) facilities. Consecutive patients reporting to cardiology center, between Jan 2015 and Oct 2016, with a definite indication for cardiac device implant were included in the study. All the procedure of implantation was done in the operation theatre under 'C' arm under local anesthesia with continuous cardiac monitoring and critical care back up.
RESULTS: Total 58 device implantations were done from Jan 2015 to Oct 2016. The mean age of the patients was 67.15 ± 10.85 years. Males constituted almost two third (68.9%) of patients. The commonest indication for device implantation was sinus node dysfunction in 60.34% followed by complete heart block in 25.86% and ventricular tachycardia in 12.06%. No post procedure infection was observed in our study.
CONCLUSION: Device implantation constitute a major group of life saving interventions in cardiology practice. Our study has emphasised that when appropriate aseptic measures are taken during device implantation at peripheral centres, the complications rate are comparable to interventions done at advance cardiac centres.

Entities:  

Keywords:  Arrhythmia; Cardiac devices; Conduction disorders; Pocket infection

Year:  2017        PMID: 29692482      PMCID: PMC5912105          DOI: 10.1016/j.mjafi.2017.11.002

Source DB:  PubMed          Journal:  Med J Armed Forces India        ISSN: 0377-1237


  9 in total

Review 1.  Epidemiology of sudden cardiac death: clinical and research implications.

Authors:  Sumeet S Chugh; Kyndaron Reinier; Carmen Teodorescu; Audrey Evanado; Elizabeth Kehr; Mershed Al Samara; Ronald Mariani; Karen Gunson; Jonathan Jui
Journal:  Prog Cardiovasc Dis       Date:  2008 Nov-Dec       Impact factor: 8.194

2.  Implantable electrophysiologic cardiac device infections: a risk factor analysis.

Authors:  D Raad; J Irani; E G Akl; S Choueiri; E Azar; J Abboud; C Afif
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2012-08-25       Impact factor: 3.267

3.  Gender and outcomes after primary prevention implantable cardioverter-defibrillator implantation: Findings from the National Cardiovascular Data Registry (NCDR).

Authors:  Andrea M Russo; Stacie L Daugherty; Frederick A Masoudi; Yongfei Wang; Jeptha Curtis; Rachel Lampert
Journal:  Am Heart J       Date:  2015-04-23       Impact factor: 4.749

4.  Standards for device implantation and follow-up: personnel, equipment, and facilities: results of the European Heart Rhythm Association Survey.

Authors:  Derick Todd; Maria Grazia Bongiorni; Antonio Hernandez-Madrid; Nikolaos Dagres; Elena Sciaraffia; Carina Blomström-Lundqvist
Journal:  Europace       Date:  2014-08       Impact factor: 5.214

Review 5.  Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysis.

Authors:  Konstantinos A Polyzos; Athanasios A Konstantelias; Matthew E Falagas
Journal:  Europace       Date:  2015-05       Impact factor: 5.214

6.  Prevention of Cardiac Implantable Electronic Device Infections: Single Operator Technique with Use of Povidone-Iodine, Double Gloving, Meticulous Aseptic/Antiseptic Measures and Antibiotic Prophylaxis.

Authors:  Antonis S Manolis; Helen Melita
Journal:  Pacing Clin Electrophysiol       Date:  2017-01-17       Impact factor: 1.976

7.  Risk factors for infection of implantable cardiac devices: data from a registry of 2496 patients.

Authors:  Benoit Hercé; Pierre Nazeyrollas; François Lesaffre; Raphael Sandras; Jean-Pierre Chabert; Angéline Martin; Sophie Tassan-Mangina; Huu Tri Bui; Damien Metz
Journal:  Europace       Date:  2012-10-24       Impact factor: 5.214

Review 8.  Pacemaker implantation in small hospitals: complication rates comparable to larger centres.

Authors:  Bjørn Haug; Kjærsti Kjelsberg; Knut Tore Lappegård
Journal:  Europace       Date:  2011-06-28       Impact factor: 5.214

Review 9.  Guidance on reuse of cardio-vascular catheters and devices in India: A consensus document.

Authors:  Aditya Kapoor; Amit Vora; Gita Nataraj; Sundeep Mishra; Prafulla Kerkar; C N Manjunath
Journal:  Indian Heart J       Date:  2017-04-13
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.