A comparison of two- and three-dimensional methods for the determination of the orientation of total hip prostheses was made in a group of 57 patients. The acetabular inclination and the collum-diaphyseal angle measured on a.p. projections (2-D) were adequate in most cases for assessing how vertically the prosthetic component was inserted, but in individual cases with a high degree of version these measurements could be misleading. Anteversion measured in the transverse plane (2-D) was more sensitive to errors than planar anteversion measured as a rotation around the longest diameter of the ellipsoid projection of the acetabular opening, but it gave a rough estimate of the relation of the prosthetic components. Determination of the spatial (3-D) orientation of the components provides a precise estimate of the component relations.

Entities:  

Mesh:

Year:  1988        PMID: 2968109

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  9 in total

Review 1.  Imaging and navigation measurement of acetabular component position in THA.

Authors:  Zhinian Wan; Aamer Malik; Branislav Jaramaz; Lisa Chao; Lawrence D Dorr
Journal:  Clin Orthop Relat Res       Date:  2008-11-01       Impact factor: 4.176

2.  Accuracy of computer navigation for acetabular component placement in THA.

Authors:  James A Ryan; Amir A Jamali; William L Bargar
Journal:  Clin Orthop Relat Res       Date:  2009-07-24       Impact factor: 4.176

3.  A cadaver study validating CT assessment of acetabular component orientation: the Perth CT hip protocol.

Authors:  Varun Arora; Richard Hannan; Richard Beaver; Timothy Fletcher; Paul Harvie
Journal:  Skeletal Radiol       Date:  2016-11-08       Impact factor: 2.199

Review 4.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

5.  Acetabular Version Measurement in Total Hip Arthroplasty: the Impact of Inclination and the Value of Multi-Planar CT Reformation.

Authors:  Michael Loftus; Yan Ma; Bernard Ghelman
Journal:  HSS J       Date:  2015-01-13

6.  The accuracy of free-hand cup positioning--a CT based measurement of cup placement in 105 total hip arthroplasties.

Authors:  G Saxler; A Marx; D Vandevelde; U Langlotz; M Tannast; M Wiese; U Michaelis; G Kemper; P A Grützner; R Steffen; M von Knoch; T Holland-Letz; K Bernsmann
Journal:  Int Orthop       Date:  2004-05-15       Impact factor: 3.075

7.  Clinical and radiological outcomes of total hip arthroplasty in patients affected by Paget's disease: a combined registry and single-institution retrospective observational study.

Authors:  Alberto Di Martino; Maria Antonietta Rita Coppola; Barbara Bordini; Niccolò Stefanini; Giuseppe Geraci; Federico Pilla; Francesco Traina; Cesare Faldini
Journal:  J Orthop Traumatol       Date:  2021-03-17

8.  Eleven year results of total hip arthroplasty in patients with secondary osteoarthritis due to slipped capital femoral epiphysis.

Authors:  Benjamin Schoof; Mustafa Citak; Padhraig F O'Loughlin; Daniel Kendoff; Carl Haasper; Thorsten Gehrke; Matthias Gebauer
Journal:  Open Orthop J       Date:  2013-05-17

9.  Measurement of acetabular inclination and anteversion via CT generated 3D pelvic model.

Authors:  R Y Wang; W H Xu; X C Kong; L Yang; S H Yang
Journal:  BMC Musculoskelet Disord       Date:  2017-08-29       Impact factor: 2.362

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.