An amperometric needle-type glucose sensor tested in rats and man.

D R Matthews1, E Bown, T W Beck, E Plotkin, L Lock, E Gosden, M Wickham.   

Abstract

An amperometric glucose-measuring 25 gauge (0.5 mm diameter) needle-type sensor has been developed using a glucose oxidase and dimethyl ferrocene paste behind a semi-permeable membrane situated over a window in the needle. Electron transfer results in direct current generation. Sensors have been tested subcutaneously in the abdomen both in anaesthetized rats (40 sensors, 11 rats) and in normal, conscious man (20 sensors, 10 subjects). In rats the blood glucose was modulated by glucose and by insulin infusion. In man the glucose concentrations were rapidly changed by use of a glucose clamp at 12 mmol/l plasma concentration for 2 h, after which the glucose returned to normal. In rats the median correlation between glucose change was 0.83 with an interquartile range from 0.70 to 0.92, and in man the median correlation was 0.80 with an interquartile range 0.67 to 0.86. Hysteresis, a measure of the accuracy on the upswing and downswing, was not a problem and cross-correlation showed no phase-lag. There were quantitative differences between in vitro calibration and the performance in vivo, reflecting the different conditions of use. The current in response to a glucose concentration was stable over 6.0 h in rats and 4.5 h in man.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 2967146     DOI: 10.1111/j.1464-5491.1988.tb00978.x

Source DB:  PubMed          Journal:  Diabet Med        ISSN: 0742-3071            Impact factor:   4.359


  8 in total

1.  A biocompatible needle-type glucose sensor based on platinum-electroplated carbon electrode.

Authors:  C Y Chen; E Tamiya; K Ishihara; Y Kosugi; Y C Su; N Nakabayashi; I Karube
Journal:  Appl Biochem Biotechnol       Date:  1992-09       Impact factor: 2.926

2.  Continuous amperometric monitoring of glucose in a brittle diabetic chimpanzee with a miniature subcutaneous electrode.

Authors:  J G Wagner; D W Schmidtke; C P Quinn; T F Fleming; B Bernacky; A Heller
Journal:  Proc Natl Acad Sci U S A       Date:  1998-05-26       Impact factor: 11.205

3.  Minimizing the impact of time lag variability on accuracy evaluation of continuous glucose monitoring systems.

Authors:  Cosimo Scuffi; Fausto Lucarelli; Francesco Valgimigli
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

4.  A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit.

Authors:  V Poitout; D Moatti-Sirat; G Reach; Y Zhang; G S Wilson; F Lemonnier; J C Klein
Journal:  Diabetologia       Date:  1993-07       Impact factor: 10.122

5.  Automated feedback control of subcutaneous glucose concentration in diabetic dogs.

Authors:  K Rebrin; U Fischer; T von Woedtke; P Abel; E Brunstein
Journal:  Diabetologia       Date:  1989-08       Impact factor: 10.122

6.  Interstitium versus Blood Equilibrium in Glucose Concentration and its Impact on Subcutaneous Continuous Glucose Monitoring Systems.

Authors:  Cosimo Scuffi
Journal:  Eur Endocrinol       Date:  2014-02-28

7.  In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer.

Authors:  J C Pickup; G W Shaw; D J Claremont
Journal:  Diabetologia       Date:  1989-03       Impact factor: 10.122

8.  Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue.

Authors:  D Moatti-Sirat; F Capron; V Poitout; G Reach; D S Bindra; Y Zhang; G S Wilson; D R Thévenot
Journal:  Diabetologia       Date:  1992-03       Impact factor: 10.122

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.