Literature DB >> 1288410

A biocompatible needle-type glucose sensor based on platinum-electroplated carbon electrode.

C Y Chen1, E Tamiya, K Ishihara, Y Kosugi, Y C Su, N Nakabayashi, I Karube.   

Abstract

A biocompatible needle-type glucose sensor with a 3-electrode configuration was constructed. A platinum-electroplated carbon stick was used as the working electrode, Ag/AgCl as the reference electrode, and a disposable hypodermic needle made of stainless steel as the counter electrode. A Nafion membrane, an immobilized glucose oxidase (GOD) membrane, and a biocompatible membrane with diffusion-limiting effect were coated successively onto the working electrode. The sensor showed a rapid response (< 120 s in batch operation), good reproducibility (RE < 3%), good stability (over 36 h in control serum), a wide dynamic range (5-600 mg/dL glucose), and superior biocompatibility. It was used to determine glucose in serum. The data obtained from the sensor showed good agreement with that from a clinical autoanalyzer (R > 0.95).

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1288410     DOI: 10.1007/bf02921780

Source DB:  PubMed          Journal:  Appl Biochem Biotechnol        ISSN: 0273-2289            Impact factor:   2.926


  13 in total

1.  In vitro and in vivo stability of electrode potentials in needle-type glucose sensors. Influence of needle material.

Authors:  G Velho; P Froguel; R Sternberg; D R Thevenot; G Reach
Journal:  Diabetes       Date:  1989-02       Impact factor: 9.461

2.  Evaluating in vitro and in vivo the interference of ascorbate and acetaminophen on glucose detection by a needle-type glucose sensor.

Authors:  D Moatti-Sirat; G Velho; G Reach
Journal:  Biosens Bioelectron       Date:  1992       Impact factor: 10.618

3.  Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring.

Authors:  D S Bindra; Y Zhang; G S Wilson; R Sternberg; D R Thévenot; D Moatti; G Reach
Journal:  Anal Chem       Date:  1991-09-01       Impact factor: 6.986

4.  IR spectral changes of bovine serum albumin upon surface adsorption.

Authors:  T J Lenk; B D Ratner; R M Gendreau; K K Chittur
Journal:  J Biomed Mater Res       Date:  1989-06

5.  Temporal characterization of perfluorinated ion exchange coated microvoltammetric electrodes for in vivo use.

Authors:  E W Kristensen; W G Kuhr; R M Wightman
Journal:  Anal Chem       Date:  1987-07-15       Impact factor: 6.986

6.  An enzyme electrode for the amperometric determination of glucose.

Authors:  G G Guilbault; G J Lubrano
Journal:  Anal Chim Acta       Date:  1973-05       Impact factor: 6.558

7.  Comparison of the pulsed amperometric detection of carbohydrates at gold and platinum electrodes for flow injection and liquid chromatographic systems.

Authors:  G G Neuburger; D C Johnson
Journal:  Anal Chem       Date:  1987-01-01       Impact factor: 6.986

8.  Reduced thrombogenicity of polymers having phospholipid polar groups.

Authors:  K Ishihara; R Aragaki; T Ueda; A Watenabe; N Nakabayashi
Journal:  J Biomed Mater Res       Date:  1990-08

9.  Fabrication and long-term implantation of semi-compliant small vascular prosthesis.

Authors:  S Murabayashi; H Kambic; H Harasaki; T Morimoto; R Yozu; Y Nose
Journal:  Trans Am Soc Artif Intern Organs       Date:  1985

10.  Potentially-implantable, ferrocene-mediated glucose sensor.

Authors:  D J Claremont; C Penton; J C Pickup
Journal:  J Biomed Eng       Date:  1986-07
View more
  4 in total

1.  Improved performance of intravascular pO2 sensor incorporating poly(MPC-co-BMA) membrane.

Authors:  S Zhang; G Wright; M A Kingston; P Rolfe
Journal:  Med Biol Eng Comput       Date:  1996-07       Impact factor: 2.602

Review 2.  Haemocompatibility of invasive sensors.

Authors:  Y Benmakroha; S Zhang; P Rolfe
Journal:  Med Biol Eng Comput       Date:  1995-11       Impact factor: 2.602

3.  Glucose sensors based on enzyme immobilization onto biocompatible membranes obtained by radiation-induced polymerization.

Authors:  L Doretti; D Ferrara; G Barison; S Lora
Journal:  Appl Biochem Biotechnol       Date:  1994-12       Impact factor: 2.926

Review 4.  A comprehensive review of glucose biosensors based on nanostructured metal-oxides.

Authors:  Md Mahbubur Rahman; A J Saleh Ahammad; Joon-Hyung Jin; Sang Jung Ahn; Jae-Joon Lee
Journal:  Sensors (Basel)       Date:  2010-05-12       Impact factor: 3.576

  4 in total