Literature DB >> 18834475

The world survey of cardiac pacing and cardioverter-defibrillators: calendar year 2005 an International Cardiac Pacing and Electrophysiology Society (ICPES) project.

Harry G Mond1, Marleen Irwin, Hugo Ector, Alessandro Proclemer.   

Abstract

BACKGROUND: A worldwide cardiac pacing and implantable cardioverter-defibrillator (ICD) survey was undertaken for calendar year 2005 and compared to a similar survey conducted in 2001.
RESULTS: There were contributions from 43 countries: 16 from Europe, 13 from the Asia Pacific region, four from the Middle East and Africa, and 10 from the Americas. The United States had the largest number of cardiac pacemaker implants (223,425). Virtually all countries showed increases in implant numbers over the 4 years. High-degree atrioventricular block and sick sinus syndrome remain the major indications for implantation of a cardiac pacemaker, although indications data were not available for large implanting regions such as Europe, Australia, and the United States. There remains a high percentage of VVI(R) pacing in the developing countries, although compared to the 2001 survey, virtually all countries had increased the percentage of DDDR implants, together with a fall in single-lead VDD implants. Pacing leads were predominantly transvenous, bipolar, and passive fixation. There was, however, an increased use of active fixation leads in both the atrium and ventricle. All countries surveyed showed a significant rise in the use of ICDs with the largest implanter being the United States (119,121) with 401 new implants per million population.
CONCLUSIONS: Although the numbers of participating countries have fallen, there still remains a group of loyal enthusiastic survey coordinators. Recruitment of new coordinators will hopefully continue in order to obtain a fully global experience of cardiac pacing and ICD usage.

Entities:  

Mesh:

Year:  2008        PMID: 18834475     DOI: 10.1111/j.1540-8159.2008.01164.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  37 in total

1.  A Comparative Survey of Pacemaker Implantation in Trinidad and Tobago in 2005 and 2009.

Authors:  R Henry; T Dookie; E Primus
Journal:  West Indian Med J       Date:  2014-05-15       Impact factor: 0.171

2.  Sudden cardiac death in low- and middle-income countries.

Authors:  Rajesh Vedanthan; Valentin Fuster; Avi Fischer
Journal:  Glob Heart       Date:  2012-12-05

3.  Necrotizing fasciitis secondary to the insertion of a cardiac pacemaker.

Authors:  Padmanabhan Subramanian; Sophie Shilston; Shanjitha Kantharuban; Srinivasan Iyer
Journal:  J R Soc Med       Date:  2012-11       Impact factor: 5.344

4.  Choosing pacemakers appropriately.

Authors:  G K Panicker; B Desai; Y Lokhandwala
Journal:  Heart Asia       Date:  2009-01-01

5.  "I felt like the angel of death": role conflicts and moral distress among allied professionals employed by the US cardiovascular implantable electronic device industry.

Authors:  Paul S Mueller; Abigale L Ottenberg; David L Hayes; Barbara A Koenig
Journal:  J Interv Card Electrophysiol       Date:  2011-08-23       Impact factor: 1.900

6.  "Just Because We Can Doesn't Mean We Should": views of nurses on deactivation of pacemakers and implantable cardioverter-defibrillators.

Authors:  Daniel B Kramer; Abigale L Ottenberg; Samantha Gerhardson; Luke A Mueller; Sharon R Kaufman; Barbara A Koenig; Paul S Mueller
Journal:  J Interv Card Electrophysiol       Date:  2011-07-30       Impact factor: 1.900

7.  Radiotherapy in patients with cardiac implantable electronic devices: clinical and dosimetric aspects.

Authors:  Giulia Riva; Ombretta Alessandro; Ruggero Spoto; Annamaria Ferrari; Cristina Garibaldi; Federica Cattani; Rosa Luraschi; Elena Rondi; Nicola Colombo; Fulvio Lorenzo Francesco Giovenzana; Carlo Maria Cipolla; Mikolaj Winnicki; Martina Persiani; Fabiana Castelluccia; Massimo Sarra Fiore; Roberto Orecchia; Barbara Alicja Jereczek-Fossa
Journal:  Med Oncol       Date:  2018-04-17       Impact factor: 3.064

Review 8.  Cell-cell junction remodeling in the heart: possible role in cardiac conduction system function and arrhythmias?

Authors:  Valeria Mezzano; Farah Sheikh
Journal:  Life Sci       Date:  2011-12-28       Impact factor: 5.037

9.  Initial experience of pacemaker and implantable cardioverter defibrillator lead extraction with the new GlideLight 80 Hz laser sheaths.

Authors:  Samer Hakmi; Simon Pecha; Björn Sill; Beate Reiter; Stephan Willems; Muhammet Ali Aydin; Yalin Yildirim; Hermann Reichenspurner; Hendrik Treede
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-09-30

10.  Reuse of infected cardiac rhythm management devices in the same individual.

Authors:  Duan Jiangbo; Li Xuebin; Zhang Ping; Wang Long; Li Ding; Chu Xianming; Ze Feng; Fang Yong; Yuan Cuizhen; Guo Jihong
Journal:  J Interv Card Electrophysiol       Date:  2012-05-13       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.