Literature DB >> 29656321

Multi-center reproducibility of structural, diffusion tensor, and resting state functional magnetic resonance imaging measures.

S Deprez1,2, Michiel B de Ruiter3, S Bogaert4, R Peeters1,2, J Belderbos5, D De Ruysscher6,7, S Schagen8, S Sunaert1,2, P Pullens9, E Achten4.   

Abstract

PURPOSE: The aim of this study is to assess multi-center reproducibility and longitudinal consistency of MRI imaging measurements, as part of a phase III longitudinal multi-center study comparing the neurotoxic effect following prophylactic cranial irradiation with hippocampal avoidance (HA-PCI), in comparison with conventional PCI in patients with small-cell lung cancer.
METHODS: Harmonized MRI acquisition protocols from six participating sites and two different vendors were compared using both physical and human phantoms. We assessed variability across sites and time points by evaluating various phantoms and data including hippocampal volume, diffusion metrics, and resting-state fMRI, from two healthy volunteers.
RESULTS: We report average coefficients of variation (CV) below 5% for intrascanner, intravendor, and intervendor reproducibility for both structural and diffusion imaging metrics, except for diffusion metrics obtained from tractography with average CVs ranging up to 7.8%. Additionally, resting-state fMRI showed stable temporal SNR and reliable generation of subjects DMN across vendors and time points.
CONCLUSION: These findings indicate that the presented multi-site MRI acquisition protocol can be used in a longitudinal study design and that pooling of the acquired data as part of the phase III longitudinal HA-PCI project is possible with careful monitoring of the results of the half-yearly QA assessment to follow-up on potential scanner-related longitudinal changes in image quality.

Entities:  

Keywords:  Diffusion tensor imaging; Multi-center; Reproducibility; Resting state fMRI; Structural MRI

Mesh:

Year:  2018        PMID: 29656321     DOI: 10.1007/s00234-018-2017-1

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  38 in total

1.  Multicenter stability of diffusion tensor imaging measures: a European clinical and physical phantom study.

Authors:  Stefan J Teipel; Sigrid Reuter; Bram Stieltjes; Julio Acosta-Cabronero; Ulrike Ernemann; Andreas Fellgiebel; Massimo Filippi; Giovanni Frisoni; Frank Hentschel; Frank Jessen; Stefan Klöppel; Thomas Meindl; Petra J W Pouwels; Karl-Heinz Hauenstein; Harald Hampel
Journal:  Psychiatry Res       Date:  2011-11-09       Impact factor: 3.222

2.  A validation study of multicenter diffusion tensor imaging: reliability of fractional anisotropy and diffusivity values.

Authors:  R J Fox; K Sakaie; J-C Lee; J P Debbins; Y Liu; D L Arnold; E R Melhem; C H Smith; M D Philips; M Lowe; E Fisher
Journal:  AJNR Am J Neuroradiol       Date:  2011-12-15       Impact factor: 3.825

3.  Quality assurance multicenter comparison of different MR scanners for quantitative diffusion-weighted imaging.

Authors:  Giacomo Belli; Simone Busoni; Antonio Ciccarone; Angela Coniglio; Marco Esposito; Marco Giannelli; Lorenzo N Mazzoni; Luca Nocetti; Roberto Sghedoni; Roberto Tarducci; Giovanna Zatelli; Rosa A Anoja; Gina Belmonte; Nicola Bertolino; Margherita Betti; Cristiano Biagini; Alberto Ciarmatori; Fabiola Cretti; Emma Fabbri; Luca Fedeli; Silvano Filice; Christian P L Fulcheri; Chiara Gasperi; Paola A Mangili; Silvia Mazzocchi; Gabriele Meliadò; Sabrina Morzenti; Linhsia Noferini; Nadia Oberhofer; Laura Orsingher; Nicoletta Paruccini; Goffredo Princigalli; Mariagrazia Quattrocchi; Adele Rinaldi; Danilo Scelfo; Gloria Vilches Freixas; Leonardo Tenori; Ileana Zucca; Claudio Luchinat; Cesare Gori; Gianni Gobbi
Journal:  J Magn Reson Imaging       Date:  2015-05-26       Impact factor: 4.813

4.  RAPID: a routine assurance pipeline for imaging of diffusion.

Authors:  S De Santis; C J Evans; D K Jones
Journal:  Magn Reson Med       Date:  2012-08-24       Impact factor: 4.668

5.  Multisite longitudinal reliability of tract-based spatial statistics in diffusion tensor imaging of healthy elderly subjects.

Authors:  Jorge Jovicich; Moira Marizzoni; Beatriz Bosch; David Bartrés-Faz; Jennifer Arnold; Jens Benninghoff; Jens Wiltfang; Luca Roccatagliata; Agnese Picco; Flavio Nobili; Oliver Blin; Stephanie Bombois; Renaud Lopes; Régis Bordet; Valérie Chanoine; Jean-Philippe Ranjeva; Mira Didic; Hélène Gros-Dagnac; Pierre Payoux; Giada Zoccatelli; Franco Alessandrini; Alberto Beltramello; Núria Bargalló; Antonio Ferretti; Massimo Caulo; Marco Aiello; Monica Ragucci; Andrea Soricelli; Nicola Salvadori; Roberto Tarducci; Piero Floridi; Magda Tsolaki; Manos Constantinidis; Antonios Drevelegas; Paolo Maria Rossini; Camillo Marra; Josephin Otto; Martin Reiss-Zimmermann; Karl-Titus Hoffmann; Samantha Galluzzi; Giovanni B Frisoni
Journal:  Neuroimage       Date:  2014-07-12       Impact factor: 6.556

6.  Demonstration of nonlinearity bias in the measurement of the apparent diffusion coefficient in multicenter trials.

Authors:  Dariya I Malyarenko; David Newitt; Lisa J Wilmes; Alina Tudorica; Karl G Helmer; Lori R Arlinghaus; Michael A Jacobs; Guido Jajamovich; Bachir Taouli; Thomas E Yankeelov; Wei Huang; Thomas L Chenevert
Journal:  Magn Reson Med       Date:  2015-05-02       Impact factor: 4.668

7.  MRI-derived measurements of human subcortical, ventricular and intracranial brain volumes: Reliability effects of scan sessions, acquisition sequences, data analyses, scanner upgrade, scanner vendors and field strengths.

Authors:  Jorge Jovicich; Silvester Czanner; Xiao Han; David Salat; Andre van der Kouwe; Brian Quinn; Jenni Pacheco; Marilyn Albert; Ronald Killiany; Deborah Blacker; Paul Maguire; Diana Rosas; Nikos Makris; Randy Gollub; Anders Dale; Bradford C Dickerson; Bruce Fischl
Journal:  Neuroimage       Date:  2009-02-20       Impact factor: 6.556

8.  Identical, but not the same: intra-site and inter-site reproducibility of fractional anisotropy measures on two 3.0T scanners.

Authors:  Christian Vollmar; Jonathan O'Muircheartaigh; Gareth J Barker; Mark R Symms; Pamela Thompson; Veena Kumari; John S Duncan; Mark P Richardson; Matthias J Koepp
Journal:  Neuroimage       Date:  2010-03-23       Impact factor: 6.556

9.  Multi-centre reproducibility of diffusion MRI parameters for clinical sequences in the brain.

Authors:  Matthew Grech-Sollars; Patrick W Hales; Keiko Miyazaki; Felix Raschke; Daniel Rodriguez; Martin Wilson; Simrandip K Gill; Tina Banks; Dawn E Saunders; Jonathan D Clayden; Matt N Gwilliam; Thomas R Barrick; Paul S Morgan; Nigel P Davies; James Rossiter; Dorothee P Auer; Richard Grundy; Martin O Leach; Franklyn A Howe; Andrew C Peet; Chris A Clark
Journal:  NMR Biomed       Date:  2015-04       Impact factor: 4.044

10.  Reproducibility of structural, resting-state BOLD and DTI data between identical scanners.

Authors:  Lejian Huang; Xue Wang; Marwan N Baliki; Lei Wang; A Vania Apkarian; Todd B Parrish
Journal:  PLoS One       Date:  2012-10-25       Impact factor: 3.240

View more
  3 in total

1.  A longitudinal human phantom reliability study of multi-center T1-weighted, DTI, and resting state fMRI data.

Authors:  Colin Hawco; Joseph D Viviano; Sofia Chavez; Erin W Dickie; Navona Calarco; Peter Kochunov; Miklos Argyelan; Jessica A Turner; Anil K Malhotra; Robert W Buchanan; Aristotle N Voineskos
Journal:  Psychiatry Res Neuroimaging       Date:  2018-06-09       Impact factor: 2.376

2.  A longitudinal multi-scanner multimodal human neuroimaging dataset.

Authors:  Colin Hawco; Erin W Dickie; Gabrielle Herman; Jessica A Turner; Miklos Argyelan; Anil K Malhotra; Robert W Buchanan; Aristotle N Voineskos
Journal:  Sci Data       Date:  2022-06-14       Impact factor: 8.501

3.  Test-retest reproducibility of a multi-atlas automated segmentation tool on multimodality brain MRI.

Authors:  Thiago J R Rezende; Brunno M Campos; Johnny Hsu; Yue Li; Can Ceritoglu; Kwame Kutten; Marcondes C França Junior; Susumu Mori; Michael I Miller; Andreia V Faria
Journal:  Brain Behav       Date:  2019-09-04       Impact factor: 2.708

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.