Literature DB >> 29643746

Bias and SNR of T1 estimates derived from joint fitting of actual flip-angle and FLASH imaging data with variable flip angles.

M Dylan Tisdall1.   

Abstract

Previous work has suggested fitting joint AFI/FLASH data for T1 and B1+ by minimizing the 2-norm of the difference between the signal model and measurements will produce unbiased estimates of T1. We demonstrate that, contrary to previous results, the estimator has a substantial bias that varies with both the true T1 and B1+, and the receive channel count. We also demonstrate that the correct ML estimator removes the effect of channel count, and that the choice of AFI protocol has a larger impact of the quality of estimates than the addition of an extra FLASH scan.

Entities:  

Year:  2017        PMID: 29643746      PMCID: PMC5891138     

Source DB:  PubMed          Journal:  Proc Int Soc Magn Reson Med Sci Meet Exhib Int Soc Magn Reson Med Sci Meet Exhib        ISSN: 1524-6965


  7 in total

1.  Determination of optimal angles for variable nutation proton magnetic spin-lattice, T1, and spin-spin, T2, relaxation times measurement.

Authors:  Sean C L Deoni; Terry M Peters; Brian K Rutt
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

2.  Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field.

Authors:  Vasily L Yarnykh
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

3.  Sequence-independent segmentation of magnetic resonance images.

Authors:  Bruce Fischl; David H Salat; André J W van der Kouwe; Nikos Makris; Florent Ségonne; Brian T Quinn; Anders M Dale
Journal:  Neuroimage       Date:  2004       Impact factor: 6.556

4.  Estimating T1 from multichannel variable flip angle SPGR sequences.

Authors:  Joshua D Trzasko; Petrice M Mostardi; Stephen J Riederer; Armando Manduca
Journal:  Magn Reson Med       Date:  2012-07-17       Impact factor: 4.668

5.  Optimizing the precision in T1 relaxation estimation using limited flip angles.

Authors:  H Z Wang; S J Riederer; J N Lee
Journal:  Magn Reson Med       Date:  1987-11       Impact factor: 4.668

6.  Simultaneous variable flip angle-actual flip angle imaging method for improved accuracy and precision of three-dimensional T1 and B1 measurements.

Authors:  Samuel A Hurley; Vasily L Yarnykh; Kevin M Johnson; Aaron S Field; Andrew L Alexander; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

7.  Linear least-squares method for unbiased estimation of T1 from SPGR signals.

Authors:  Lin-Ching Chang; Cheng Guan Koay; Peter J Basser; Carlo Pierpaoli
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.