Sangjun Choi1, Wonseok Cha2, Jihoon Park3, Seungwon Kim4, Won Kim5, Chungsik Yoon6, Ju-Hyun Park7, Kwonchul Ha8, Donguk Park9.
Abstract
We assessed the exposure of semiconductor workers to extremely low frequency-magnetic fields (ELF-MF) and identified job characteristics affecting ELF-MF exposure. These were demonstrated by assessing the exposure of 117 workers involved in wafer fabrication (fab) and chip packaging wearing personal dosimeters for a full shift. A portable device was used to monitor ELF-MF in high temporal resolution. All measurements were categorized by operation, job and working activity during working time. ELF-MF exposure of workers were classified based on the quartiles of ELF-MF distribution. The average levels of ELF-MF exposure were 0.56 µT for fab workers, 0.59 µT for chip packaging workers and 0.89 µT for electrical engineers, respectively. Exposure to ELF-MF differed among types of factory, operation, job and activity. Workers engaged in the diffusion and chip testing activities showed the highest ELF-MF exposure. The ELF-MF exposures of process operators were found to be higher than those of maintenance engineers, although peak exposure and/or patterns varied. The groups with the highest quartile ELF-MF exposure level are operators in diffusion, ion implantation, module and testing operations, and maintenance engineers in diffusion, module and testing operations. In conclusion, ELF-MF exposure among workers can be substantially affected by the type of operation and job, and the activity or location.Entities:
Keywords: extremely low frequency-magnetic fields (ELF-MF); fabrication (fab) and chip packaging assembly; semiconductors
Mesh:
Year: 2018 PMID: 29614730 PMCID: PMC5923684 DOI: 10.3390/ijerph15040642
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 3.390
Figure 1Semiconductor worker wearing portable ELF-MF meter on the waist, indicated with dashed black circle.
Figure 2Distribution of extremely low frequency magnetic field (ELF-MF) exposure measurement by type of process and job (Abbreviations: DIFF: diffusion, IMP: ion implantation, TF: thin film, WT: wafer test, DA: die attach, MDL: module, MT: module test, TDBI: test during burn-in, EM: electric maintenance).
ELF-MF exposure level by operation within the type of semiconductor plant.
| Classification | Operation | No. of Workers | No. of Observations | AM, µT | SD, µT | GM, µT | GSD | Range, µT |
|---|---|---|---|---|---|---|---|---|
| Fabrication * | CMP | 6 | 44,242 | 0.14 | 0.29 | 0.09 | 2.47 | 0.01–16.83 |
| Photolithography | 6 | 53,883 | 0.53 | 0.46 | 0.37 | 2.54 | 0.02–21.97 | |
| Etch | 11 | 98,151 | 0.53 | 0.64 | 0.37 | 2.40 | 0.01–23.52 | |
| Diffusion | 8 | 58,672 | 1.48 | 2.00 | 0.64 | 4.50 | 0.01–35.36 | |
| Ionimplantation | 8 | 60,650 | 0.76 | 0.95 | 0.32 | 4.18 | 0.01–15.67 | |
| Thin-film | 8 | 66,598 | 0.43 | 0.77 | 0.18 | 3.64 | 0.01–17.31 | |
| Wafertest | 11 | 92,819 | 0.21 | 0.29 | 0.14 | 2.62 | 0.01–9.63 | |
| Total | 58 | 475,015 | 0.56 | 0.99 | 0.25 | 3.61 | 0.01–35.36 | |
| Chip packaging * | Dieattach | 8 | 69,152 | 0.46 | 0.38 | 0.33 | 2.41 | 0.01–15.39 |
| Module | 5 | 47,401 | 1.13 | 1.16 | 0.59 | 3.56 | 0.01–6.27 | |
| Moduletest | 11 | 105,017 | 0.39 | 0.43 | 0.27 | 2.24 | 0.02–7.71 | |
| TDBI | 14 | 105,812 | 0.39 | 0.39 | 0.28 | 2.32 | 0.03–26.72 | |
| Test | 7 | 32,480 | 1.46 | 0.90 | 1.24 | 1.80 | 0.08–21.92 | |
| Total | 45 | 359,862 | 0.59 | 0.71 | 0.36 | 2.73 | 0.01–26.72 | |
| Electric maintenance * | Maintenance | 12 | 91,481 | 0.89 | 3.11 | 0.27 | 3.55 | 0.01–109.00 |
| Management | 2 | 16,526 | 0.28 | 0.42 | 0.13 | 4.06 | 0.01–9.66 | |
| Total | 14 | 108,007 | 0.80 | 2.88 | 0.24 | 3.73 | 0.01–109.00 |
Abbreviations: CMP: chemical mechanical polishing, TDBI: test during burn-in, AM: arithmetic mean, SD: standard deviation, GM: geometric mean, GSD: geometric standard deviation. * p < 0.0001, Kruskal-Wallis rank test by operations.
ELF-MF exposure level by type of job within the type of semiconductor plant.
| Classification | Type of Job | No. of Workers | No. of Observations | AM, µT | SD, µT | GM, µT | GSD | Range, µT |
|---|---|---|---|---|---|---|---|---|
| Fabrication * | Operator | 13 | 106,987 | 0.68 | 0.85 | 0.27 | 4.23 | 0.01–12.31 |
| M/E | 45 | 368,028 | 0.53 | 1.02 | 0.25 | 3.43 | 0.01–35.36 | |
| Chip packaging * | Operator | 22 | 155,994 | 0.82 | 0.86 | 0.54 | 2.52 | 0.02–21.92 |
| M/E | 23 | 203,868 | 0.42 | 0.51 | 0.26 | 2.57 | 0.01–26.72 | |
| Electric maintenance * | Engineer | 12 | 91,481 | 0.89 | 3.11 | 0.27 | 3.55 | 0.01–109.0 |
| Manager | 2 | 16,526 | 0.28 | 0.42 | 0.13 | 4.06 | 0.01–9.66 |
Abbreviations: M/E: maintenance engineer, AM: arithmetic mean, SD: standard deviation, GM: geometric mean, GSD: geometric standard deviation. * p < 0.0001, Kruskal-Wallis rank test by jobs.
ELF-MF exposure level by type of activity within the type of semiconductor plant.
| Classification | Type of Activity or Location | No. of Observations | AM, µT | SD, µT | GM, µT | GSD | Range, µT |
|---|---|---|---|---|---|---|---|
| Fabrication * | Resting outside clean room | 51,953 | 0.27 | 0.25 | 0.17 | 2.73 | 0.01–2.51 |
| Resting inside clean room | 19,632 | 0.77 | 0.54 | 0.60 | 2.11 | 0.03–2.65 | |
| Operation work | 91,603 | 0.66 | 0.85 | 0.26 | 4.28 | 0.01–3.45 | |
| Maintenance work | 14,952 | 3.34 | 3.24 | 2.32 | 2.36 | 0.05–35.36 | |
| Near or passing process machine | 296,875 | 0.43 | 0.60 | 0.22 | 3.27 | 0.01–10.70 | |
| Chip packaging * | Resting outside clean room | 34,056 | 0.23 | 0.47 | 0.13 | 2.20 | 0.03–2.87 |
| Resting inside clean room | 11,353 | 0.55 | 0.60 | 0.37 | 2.22 | 0.09–2.58 | |
| Operation work | 130,620 | 0.73 | 0.60 | 0.54 | 2.21 | 0.02–4.41 | |
| Maintenance work | 16,294 | 2.19 | 1.59 | 1.77 | 1.93 | 0.03–26.72 | |
| Near or passing process machine | 167,539 | 0.41 | 0.42 | 0.27 | 2.45 | 0.01–4.55 | |
| Electric engineer * | Resting outside clean room | 2735 | 0.34 | 0.27 | 0.26 | 2.29 | 0.02–3.48 |
| Resting inside clean room | 994 | 1.17 | 0.79 | 0.69 | 3.62 | 0.01–2.87 | |
| Maintenance work | 3421 | 11.43 | 11.06 | 7.77 | 2.49 | 0.54–109.0 | |
| Near or passing process machine | 84,331 | 0.48 | 0.92 | 0.24 | 2.96 | 0.01–9.99 | |
| Manager of electric maintenance * | Resting outside clean room | 1072 | 0.15 | 0.15 | 0.07 | 3.81 | 0.02–0.35 |
| Office | 15,207 | 0.25 | 0.23 | 0.13 | 3.89 | 0.01–1.95 | |
| Near or passing electric device | 247 | 2.65 | 1.62 | 2.15 | 1.97 | 0.60–9.66 |
Abbreviations: AM: arithmetic mean, SD: standard deviation, GM: geometric mean, GSD: geometric standard deviation. * p < 0.0001, Kruskal-Wallis rank test by activities.
Figure 3An example of ELF-MF exposure pattern of several semiconductor workers (solid black line: operator, OP; dotted grey line: maintenance engineer, ME). (a) Diffusion worker in fabrication (arithmetic mean, AM: OP = 1.93 µT, ME = 0.78 µT); (b) Thin-film worker in fabrication (AM: OP = 1.14 µT, ME = 0.34 µT); (c) Die-attach worker in package and test (AM: OP = 0.72 µT, ME = 0.22 µT); (d) Chip-mount worker in package and test (AM: OP = 1.75 µT, ME = 0.47 µT).
Figure 4Distribution of full-shift extremely low frequency magnetic field (ELF-MF) exposure levels within each operator and maintenance engineer in the diffusion process (Dashed line: arithmetic mean).
Classification of semiconductor workers based on the distribution of ELF-MF exposure level.
| Classification | Operation | Type of Job | No of Samples | AM, uT | SD, uT | GM, uT | GSD | Range, uT | Relative Exposure Group 1 |
|---|---|---|---|---|---|---|---|---|---|
| Fabrication | CMP | M/E | 44,242 | 0.14 | 0.29 | 0.09 | 2.47 | 0.01–16.83 | Low |
| Photolithography | M/E | 53,883 | 0.53 | 0.46 | 0.37 | 2.54 | 0.02–21.97 | Moderate | |
| Etch | M/E | 98,151 | 0.53 | 0.64 | 0.37 | 2.40 | 0.01–23.52 | Moderate | |
| Diffusion | Operator | 16,869 | 1.69 | 0.81 | 1.48 | 1.71 | 0.11–4.93 | High | |
| M/E | 41,803 | 1.40 | 2.30 | 0.46 | 5.10 | 0.01–35.36 | High | ||
| Ion implantation | Operator | 17,099 | 1.74 | 0.68 | 1.50 | 1.97 | 0.04–12.31 | High | |
| M/E | 43,551 | 0.37 | 0.74 | 0.17 | 3.20 | 0.01–15.67 | Low | ||
| Thin film | Operator | 8395 | 0.24 | 0.40 | 0.18 | 1.86 | 0.04–5.93 | Low | |
| M/E | 58,203 | 0.45 | 0.81 | 0.18 | 3.90 | 0.01–17.31 | Moderate | ||
| Wafer test | Operator | 64,624 | 0.19 | 0.25 | 0.12 | 2.66 | 0.01–9.63 | Low | |
| M/E | 28,195 | 0.27 | 0.36 | 0.19 | 2.34 | 0.01–7.99 | Low | ||
| Chip packaging | Die attach | Operator | 51,536 | 0.53 | 0.39 | 0.41 | 2.10 | 0.03–15.39 | Moderate |
| M/E | 17,616 | 0.25 | 0.26 | 0.16 | 2.41 | 0.01–4.17 | Low | ||
| Module | Operator | 18,601 | 1.46 | 1.48 | 0.76 | 3.67 | 0.02–6.27 | High | |
| M/E | 28,800 | 0.91 | 0.82 | 0.50 | 3.38 | 0.01–4.55 | High | ||
| Module test | Operator | 28,799 | 0.56 | 0.52 | 0.43 | 1.99 | 0.04–7.71 | Moderate | |
| M/E | 76,218 | 0.32 | 0.37 | 0.23 | 2.17 | 0.02–3.81 | Moderate | ||
| TDBI | Operator | 24,578 | 0.43 | 0.34 | 0.33 | 2.00 | 0.04–7.43 | Moderate | |
| M/E | 81,234 | 0.37 | 0.40 | 0.26 | 2.40 | 0.03–26.72 | Moderate | ||
| Test | Operator | 32,480 | 1.46 | 0.90 | 1.24 | 1.80 | 0.08–21.92 | High | |
| Electric maintenance | Maintenance | M/E | 91,481 | 0.89 | 3.11 | 0.27 | 3.55 | 0.01–109.0 | High |
| Management | Manager | 16,526 | 0.28 | 0.42 | 0.13 | 4.06 | 0.01–9.66 | Low |
Abbreviations: CMP: chemical mechanical polishing, TDBI: test during burn-in, M/E: maintenance engineer, AM: arithmetic mean, SD: standard deviation, GM: geometric mean, GSD: geometric standard deviation. 1 Low: AM < 0.3 µT, Moderate: 0.3 ≤ AM < 0.65 µT, High: AM ≥ 0.65 µT.