Literature DB >> 29589667

An analysis of effective dose optimization and its impact on image quality and diagnostic efficacy relating to dental cone beam computed tomography (CBCT)

Margarete B McGuigan1, Henry F Duncan1, Keith Horner2.   

Abstract

The potential of high resolution, three-dimensional (3D) images which overcome limitations such as superimposition and anatomical noise of two-dimensional (2D) conventional imaging, has made cone beam computed tomography (CBCT) an increasingly popular imaging modality in many dental applications. It is in light of the increasingly prevalent use of CBCT, particularly in a primary dental care setting, that the goal of this review is to investigate what evidence-based guidance is available to the clinician to justify and reduce radiation risk of this higher dose imaging modality while maintaining diagnostically acceptable images. To this end, the literature on radiation dose and related patient risk was comprehensively investigated, before an analysis of the ways in which dose can be optimized and the implications that optimization has on image quality was discussed. Finally, although it is accepted that CBCT has the potential to improve diagnosis, it is uncertain if its use has positive ramifications on issues of diagnostic efficacy, including clinical decision-making and patient outcome. In order to investigate these issues, the levels of evidence of the existing studies and their validity were assessed. On review of the available literature, it is evident that there is limited practical advice available to dentists regarding dose optimization and any existing protocols may not be readily transferable to every CBCT machine, the manufacturers' role is not often conducive to dose limitation and that the bulk of evidence is at lower levels of evidence. Furthermore, there is minimal supporting evidence to suggest an impact of CBCT on diagnostic thinking and consequent choice of treatment and no evidence of a positive effect of CBCT on patient outcome.

Entities:  

Keywords:  CBCT; Dose; Optimization; Image Quality; Diagnostic Efficacy

Mesh:

Year:  2018        PMID: 29589667

Source DB:  PubMed          Journal:  Swiss Dent J        ISSN: 2296-6498


  9 in total

1.  Impact of metal artefacts on subjective perception of image quality of 13 CBCT devices.

Authors:  Victor Aquino Wanderley; Andre Ferreira Leite; Karla de Faria Vasconcelos; Ruben Pauwels; Francisca Müller-García; Kathrin Becker; Matheus L Oliveira; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2022-02-15       Impact factor: 3.573

2.  Development of a model of soft tissue simulation using ballistic gelatin for CBCT acquisitions related to dentomaxillofacial radiology research.

Authors:  Eduarda Helena Leandro Nascimento; Rocharles Cavalcante Fontenele; Priscila de Azeredo Lopes; Gustavo Machado Santaella; Karla Faria Vasconcelos; Deborah Queiroz de Freitas; Anne Caroline Oenning; Francisco Carlos Groppo
Journal:  Dentomaxillofac Radiol       Date:  2020-09-17       Impact factor: 2.419

3.  Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images.

Authors:  Letícia Queiroz Mauad; Paulo Victor Teixeira Doriguêtto; Daniela de Almeida; Karolina Aparecida Castilho Fardim; Alessiana Helena Machado; Karina Lopes Devito
Journal:  Dentomaxillofac Radiol       Date:  2020-09-17       Impact factor: 2.419

4.  Modern 3D cephalometry in pediatric orthodontics-downsizing the FOV and development of a new 3D cephalometric analysis within a minimized large FOV for dose reduction.

Authors:  Pamela Kissel; James K Mah; Axel Bumann
Journal:  Clin Oral Investig       Date:  2021-01-25       Impact factor: 3.573

5.  Effective dose estimation in cone-beam computed tomography for dental use by Monte-Carlo simulation optimizing calculation numbers using a step-and-shoot method.

Authors:  Yoshihiro Ozaki; Hiroshi Watanabe; Tohru Kurabayashi
Journal:  Dentomaxillofac Radiol       Date:  2021-04-30       Impact factor: 3.525

6.  Optimization of exposure parameters and relationship between subjective and technical image quality in cone-beam computed tomography.

Authors:  Ha-Na Park; Chang-Ki Min; Kyoung-A Kim; Kwang-Joon Koh
Journal:  Imaging Sci Dent       Date:  2019-06-24

Review 7.  The Impact of Cone-Beam Computed Tomography Exposure Parameters on Peri-Implant Artifacts: A Literature Review.

Authors:  Paweł Sawicki; Paweł J Zawadzki; Piotr Regulski
Journal:  Cureus       Date:  2022-03-10

8.  3D Assessment of Endodontic Lesions with a Low-Dose CBCT Protocol.

Authors:  Marco Portelli; Angela Militi; Antonino Lo Giudice; Roberto Lo Giudice; Lorenzo Rustico; Rosamaria Fastuca; Riccardo Nucera
Journal:  Dent J (Basel)       Date:  2020-05-13

9.  Cone beam CT optimisation for detection of vertical root fracture with metal in the field of view or the exomass.

Authors:  Amanda P Candemil; Benjamin Salmon; Karla F Vasconcelos; Anne C Oenning; Reinhilde Jacobs; Deborah Q Freitas; Francisco Haiter-Neto; Francesca Mangione; Matheus L Oliveira
Journal:  Sci Rep       Date:  2021-09-27       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.