Literature DB >> 29588694

Transcatheter Aortic Valve Implantation for Patients with Smaller Anatomy.

Yusuke Watanabe1, Ken Kozuma1.   

Abstract

Transcatheter aortic valve implantation (TAVI) has reached relative maturity for the treatment of severe, symptomatic aortic stenosis (AS). TAVI for patients with smaller anatomy is a challenging procedure due to specific anatomical difficulty and complications including annulus rupture and vascular complications. Prevention of these complications, and the introduction of a newer-generation and lower-profile TAVI system, will encourage the prevalence of TAVI for patients with smaller anatomy.

Entities:  

Keywords:  Transcatheter aortic valve implantation; aortic valve; small body size; vascular complication

Year:  2015        PMID: 29588694      PMCID: PMC5808663          DOI: 10.15420/ICR.2015.10.03.155

Source DB:  PubMed          Journal:  Interv Cardiol        ISSN: 1756-1485


  24 in total

1.  Potential mechanism of annulus rupture during transcatheter aortic valve implantation.

Authors:  Kentaro Hayashida; Erik Bouvier; Thierry Lefèvre; Thomas Hovasse; Marie-Claude Morice; Bernard Chevalier; Mauro Romano; Philippe Garot; Arnaud Farge; Patrick Donzeau-Gouge; Bertrand Cormier
Journal:  Catheter Cardiovasc Interv       Date:  2013-06-25       Impact factor: 2.692

Review 2.  Cardiac CT: necessary for precise sizing for transcatheter aortic implantation.

Authors:  Carl J Schultz; Adriaan D Moelker; Apostolos Tzikas; Alexia Rossi; Robert-Jan van Geuns; Pim J de Feyter; Patrick W Serruys
Journal:  EuroIntervention       Date:  2010-05       Impact factor: 6.534

3.  Impact of CT-guided valve sizing on post-procedural aortic regurgitation in transcatheter aortic valve implantation.

Authors:  Kentaro Hayashida; Erik Bouvier; Thierry Lefèvre; Thomas Hovasse; Marie-Claude Morice; Bernard Chevalier; Mauro Romano; Philippe Garot; Darren Mylotte; Arnaud Farge; Patrick Donzeau-Gouge; Bertrand Cormier
Journal:  EuroIntervention       Date:  2012-09       Impact factor: 6.534

4.  Prosthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root.

Authors:  Philipp Blanke; Jochen Reinöhl; Christian Schlensak; Matthias Siepe; Gregor Pache; Wulf Euringer; Annette Geibel-Zehender; Christopher Bode; Mathias Langer; Friedhelm Beyersdorf; Manfred Zehender
Journal:  Circ Cardiovasc Interv       Date:  2012-08-07       Impact factor: 6.546

5.  Prognostic value of aortic root calcification volume on clinical outcomes after transcatheter balloon-expandable aortic valve implantation.

Authors:  Yusuke Watanabe; Thierry Lefèvre; Erik Bouvier; Takahide Arai; Kentaro Hayashida; Bernard Chevalier; Mauro Romano; Thomas Hovasse; Philippe Garot; Patrick Donzeau-Gouge; Arnaud Farge; Bertrand Cormier; Marie-Claude Morice
Journal:  Catheter Cardiovasc Interv       Date:  2015-05-06       Impact factor: 2.692

6.  Registry of transcatheter aortic-valve implantation in high-risk patients.

Authors:  Martine Gilard; Hélène Eltchaninoff; Bernard Iung; Patrick Donzeau-Gouge; Karine Chevreul; Jean Fajadet; Pascal Leprince; Alain Leguerrier; Michel Lievre; Alain Prat; Emmanuel Teiger; Thierry Lefevre; Dominique Himbert; Didier Tchetche; Didier Carrié; Bernard Albat; Alain Cribier; Gilles Rioufol; Arnaud Sudre; Didier Blanchard; Frederic Collet; Pierre Dos Santos; Nicolas Meneveau; Ashok Tirouvanziam; Christophe Caussin; Philippe Guyon; Jacques Boschat; Herve Le Breton; Frederic Collart; Remi Houel; Stephane Delpine; Geraud Souteyrand; Xavier Favereau; Patrick Ohlmann; Vincent Doisy; Gilles Grollier; Antoine Gommeaux; Jean-Philippe Claudel; Francois Bourlon; Bernard Bertrand; Eric Van Belle; Marc Laskar
Journal:  N Engl J Med       Date:  2012-05-03       Impact factor: 91.245

7.  Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement.

Authors:  Marco Barbanti; Tae-Hyun Yang; Josep Rodès Cabau; Corrado Tamburino; David A Wood; Hasan Jilaihawi; Phillip Blanke; Raj R Makkar; Azeem Latib; Antonio Colombo; Giuseppe Tarantini; Rekha Raju; Ronald K Binder; Giang Nguyen; Melanie Freeman; Henrique B Ribeiro; Samir Kapadia; James Min; Gudrun Feuchtner; Ronen Gurtvich; Faisal Alqoofi; Marc Pelletier; Gian Paolo Ussia; Massimo Napodano; Fabio Sandoli de Brito; Susheel Kodali; Bjarne L Norgaard; Nicolaj C Hansson; Gregor Pache; Sergio J Canovas; Hongbin Zhang; Martin B Leon; John G Webb; Jonathon Leipsic
Journal:  Circulation       Date:  2013-06-07       Impact factor: 29.690

8.  Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis.

Authors:  Marie-Annick Clavel; John G Webb; Philippe Pibarot; Lukas Altwegg; Eric Dumont; Chris Thompson; Robert De Larochellière; Daniel Doyle; Jean-Bernard Masson; Sebastien Bergeron; Olivier F Bertrand; Josep Rodés-Cabau
Journal:  J Am Coll Cardiol       Date:  2009-05-19       Impact factor: 24.094

Review 9.  The problem of valve prosthesis-patient mismatch.

Authors:  S H Rahimtoola
Journal:  Circulation       Date:  1978-07       Impact factor: 29.690

10.  Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: acute and late outcomes of the multicenter Canadian experience.

Authors:  Josep Rodés-Cabau; John G Webb; Anson Cheung; Jian Ye; Eric Dumont; Christopher M Feindel; Mark Osten; Madhu K Natarajan; James L Velianou; Giuseppe Martucci; Benoît DeVarennes; Robert Chisholm; Mark D Peterson; Samuel V Lichtenstein; Fabian Nietlispach; Daniel Doyle; Robert DeLarochellière; Kevin Teoh; Victor Chu; Adrian Dancea; Kevin Lachapelle; Asim Cheema; David Latter; Eric Horlick
Journal:  J Am Coll Cardiol       Date:  2010-01-22       Impact factor: 24.094

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.