Literature DB >> 20542831

Cardiac CT: necessary for precise sizing for transcatheter aortic implantation.

Carl J Schultz1, Adriaan D Moelker, Apostolos Tzikas, Alexia Rossi, Robert-Jan van Geuns, Pim J de Feyter, Patrick W Serruys.   

Abstract

Sizing for transcutaneous aortic valve replacement (TAVI) relies on non-invasive imaging. Incorrect sizing may result in adverse outcomes including paraprosthetic regurgitation, asymmetrical expansion which may impair prosthesis durability and, in the case of severe sizing errors, device embolisation or aortic root rupture. This review addresses the optimal approach for sizing. It is based on currently available data including the anatomical implications of using different imaging modalities, the steps of how to reproducibly measure the correct annulus diameter on MSCT, and current evidence for different sizing strategies.

Entities:  

Mesh:

Year:  2010        PMID: 20542831     DOI: 10.4244/

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  12 in total

1.  Aortic valve calcium scoring is a predictor of paravalvular aortic regurgitation after transcatheter aortic valve implantation.

Authors:  Andrea Colli; Michele Gallo; Eduardo Bernabeu; Augusto D'Onofrio; Vincenzo Tarzia; Gino Gerosa
Journal:  Ann Cardiothorac Surg       Date:  2012-07

2.  Clinical and economic consequences of non-cardiac incidental findings detected on cardiovascular computed tomography performed prior to transcatheter aortic valve implantation (TAVI).

Authors:  Alistair C Lindsay; Mona Sriharan; Olga Lazoura; Arunashis Sau; Michael Roughton; Richard J Jabbour; Carlo Di Mario; Simon W Davies; Neil E Moat; Simon P G Padley; Michael B Rubens; Edward D Nicol
Journal:  Int J Cardiovasc Imaging       Date:  2015-06-12       Impact factor: 2.357

Review 3.  Paravalvular regurgitation following transcutaneous aortic valve replacement: predictors and clinical significance.

Authors:  Rebecca T Hahn; Susheel Kodali; Philippe Généreux; Martin Leon
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

Review 4.  Echocardiographic imaging of procedural complications during balloon-expandable transcatheter aortic valve replacement.

Authors:  Rebecca T Hahn; Susheel Kodali; E Murat Tuzcu; Martin B Leon; Samir Kapadia; Deepika Gopal; Stamatios Lerakis; Brian R Lindman; Zuyue Wang; John Webb; Vinod H Thourani; Pamela S Douglas
Journal:  JACC Cardiovasc Imaging       Date:  2015-03

5.  Transcatheter Aortic Valve Implantation for Patients with Smaller Anatomy.

Authors:  Yusuke Watanabe; Ken Kozuma
Journal:  Interv Cardiol       Date:  2015-09

Review 6.  Role of computed tomography imaging for transcatheter valvular repair/insertion.

Authors:  See Hooi Ewe; Robert J Klautz; Martin J Schalij; Victoria Delgado
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-26       Impact factor: 2.357

7.  Prognostic value of the ratio between prosthesis area and indexed annulus area measured by MultiSlice-CT for transcatheter aortic valve implantation procedures.

Authors:  Nicolas Debry; Arnaud Sudre; Ibrahim Elquodeimat; Cédric Delhaye; Guillaume Schurtz; Antoine Bical; Mohamad Koussa; Khalil Fattouch; Thomas Modine
Journal:  J Geriatr Cardiol       Date:  2016-09       Impact factor: 3.327

8.  Non-Cardiovascular Computed Tomography Incidental Findings in Patients Who Underwent Transaortic Valve Implantation Procedure.

Authors:  Ahmed Fathala; Mnahi Bin Saeedan; Ali Zulfiqar; Hani Al Sergani
Journal:  Cardiol Res       Date:  2017-03-03

9.  Short-term changes of blood pressure and aortic stiffness in older patients after transcatheter aortic valve implantation.

Authors:  Jeannette A Goudzwaard; Eleonora Disegna; Marjo Jag de Ronde-Tillmans; Mattie J Lenzen; Peter Pt de Jaegere; Francesco Us Mattace-Raso
Journal:  Clin Interv Aging       Date:  2019-08-02       Impact factor: 4.458

10.  Sex-specific aortic root anatomy in patients with bicuspid aortic valve undergoing TAVR in a Chinese cohort.

Authors:  F Du; X Liu; Q Zhu; Y He; J Jiang; T Napawan; S Jaiswal; Z Chen; J Wang
Journal:  Herz       Date:  2018-11-27       Impact factor: 1.443

View more