Jia Wang1, Xiaoping Shi1, Tao Xu1, Geng Wang1.
Abstract
Objectives A failed first attempt at laryngeal mask airway (LMA) insertion could increase the risk of laryngospasm, hypoxemia, and postoperative sore throat. This study was performed to investigate the risk factors for failed first-attempt LMA placement. Methods In total, 461 patients who underwent general anesthesia with a Supreme LMA (Teleflex Medical, Shanghai, China) and who had an American Society of Anesthesiologists (ASA) physical status of I to III were prospectively enrolled. The LMA was inserted after anesthetic induction. We recorded the insertion conditions and each patient's age, ASA status, body weight, body mass index (BMI), duration of anesthesia, size of LMA, and cuff pressure; the years of work experience of the anesthesiologists; and the use or nonuse of lidocaine gel as a lubricant. Results Successful first-attempt placement of the Supreme LMA was achieved in 438 (95.10%) patients, while first-attempt placement failed in 23 (4.99%). Significant risk factors for failure of first-attempt LMA insertion included high age, high body weight, BMI of <20 kg/m2, and insertion without using lidocaine gel. Conclusions A patient age of >61 years, high body weight, BMI of <20 kg/m2, and insertion without lidocaine gel could significantly increase the risk of failed first-attempt Supreme LMA insertion.Entities:
Keywords: First insertion failure; body mass index; general anesthesia; high body weight; laryngeal mask airway; lidocaine gel
Mesh:
Year: 2018 PMID: 29569985 PMCID: PMC5991247 DOI: 10.1177/0300060518762666
Source DB: PubMed Journal: J Int Med Res ISSN: 0300-0605 Impact factor: 1.671
Patient and anesthetic characteristics
| Parameter | Successful first-attempt LMA insertion (n = 438) | Failed first-attempt LMA insertion (n = 23) | |
|---|---|---|---|
| Sex (Male/Female) | 228 (52.1)/210 (47.9) | 17 (73.9)/6 (26.1) | 0.053 |
| Age | |||
| Mean age (years) | 44.4 ± 19.0 | 50.3 ± 20.1 | 0.153 |
| <18 | 56 (12.8) | 1 (4.3) | 0.051 |
| 19–40 | 123 (28.1) | 8 (34.8) | |
| 41–60 | 160 (36.5) | 4 (17.4) | |
| >61 | 99 (22.6) | 10 (43.5) | |
| Body weight (kg) | 66.69 ± 14.53 | 75.21 ± 14.00 | 0.007* |
| BMI (kg/m2) | |||
| <20 | 58 (13.2) | 1 (4.3) | 0.027* |
| 20–24 | 148 (33.8) | 3 (13.0) | |
| 24–28 | 156 (35.6) | 15 (65.2) | |
| >28 | 76 (17.4) | 4 (17.4) | |
| ASA status | 0.460 | ||
| I | 235 (53.7) | 14 (60.9) | |
| II | 191 (43.6) | 8 (34.8) | |
| III | 12 (2.7) | 1 (4.3) | |
| Lidocaine gel (yes/no) | 400 (91.3)/38 (8.7) | 17 (73.9)/6 (26.1) | 0.016* |
| Duration of anesthesia (minutes) | 138.09 ± 57.78 | 123.32 ± 44.19 | 0.238 |
| Size of LMA | 0.346 | ||
| 2 | 7 (1.6) | 0 (0.0) | |
| 2.5 | 3 (0.7) | 0 (0.0) | |
| 3 | 216 (49.3) | 7 (30.4) | |
| 4 | 210 (47.9) | 16 (69.6) | |
| 5 | 2 (0.5) | 0 (0.0) | |
| Cuff pressure (Pa) | 0.374 | ||
| <40 | 42 (9.6) | 2 (13.0) | |
| 40–80 | 102 (23.3) | 2 (8.7) | |
| 80–120 | 103 (23.5) | 6 (26.1) | |
| >120 | 191 (43.6) | 12 (52.2) | |
| Doctors’ work experience (years) | 0.224 | ||
| 1–2 | 121 (27.6) | 9 (39.1) | |
| 3–5 | 70 (16.0) | 5 (21.7) | |
| >5 | 247 (56.4) | 9 (39.1) |
Data are presented as n (%) or mean ± standard deviation. LMA, laryngeal mask airway; BMI, body mass index; ASA, American Society of Anesthesiologists. *Statistically significant.
Multivariate analysis of first-attempt LMA insertion
| Parameter | Successful first-attempt LMA insertion (n = 438) | Failed first-attempt LMA insertion | Odds ratio (95% CI) | |
|---|---|---|---|---|
| Sex | 0.386 (0.146–1.017) | 0.054 | ||
| Male | 228 (52.1) | 17 (73.9) | ||
| Female | 210 (47.9) | 6 (26.1) | ||
| Age (years) | 1.814 (1.054–3.121) | 0.031* | ||
| <18 | 56 (12.8) | 1 (4.3) | ||
| 19–40 | 123 (28.1) | 8 (34.8) | ||
| 41–60 | 160 (36.5) | 4 (17.4) | ||
| >61 | 99 (22.6) | 10 (43.5) | ||
| Body weight (kg) | 66.69 ± 14.53 | 75.21 ± 14.00 | 1.043 (1.011–1.075) | 0.007 |
| BMI (kg/m2) | ||||
| <20 | 58 (13.2) | 1 (4.3) | 1.765 (1.063–2.932) | 0.028* |
| 20–24 | 148 (33.8) | 3 (13.0) | ||
| 24–28 | 156 (35.6) | 15 (65.2) | ||
| >28 | 76 (17.4) | 4 (17.4) | ||
| Lidocaine gel | 3.736 (1.350–10.337) | 0.011* | ||
| Yes | 400 (91.3) | 17 (73.9) | ||
| No | 38 (8.7) | 6 (26.1) |
Data are presented as n (%) or mean ± standard deviation. LMA, laryngeal mask airway; BMI, body mass index; CI, confidence interval. *Statistically significant.