Literature DB >> 29567650

The New Low-Profile WEB 17 System for Treatment of Intracranial Aneurysms: First Clinical Experiences.

S B T van Rooij1, J P Peluso2, M Sluzewski2, H G Kortman2, W J van Rooij2.   

Abstract

BACKGROUND AND
PURPOSE: The Woven EndoBridge (WEB) is an intrasaccular flow diverter intended to treat wide-neck aneurysms. The latest generation WEBs needed a 0.021-inch microcatheter in the small sizes. Recently, a lower profile range of WEBs compliant with a 0.017-inch microcatheter (WEB 17) has been introduced. We present the first clinical results of treatment of both ruptured and unruptured aneurysms with the WEB 17.
MATERIALS AND METHODS: Between December 2016 and September 2017, forty-six aneurysms in 40 patients were treated with the WEB 17. No supporting stents or balloons were used. Twenty-five aneurysms were ruptured (54%). There were 6 men and 34 women (mean age, 62 years; median, 63 years; range, 46-87 years). The mean aneurysm size was 4.9 mm (median, 5 mm; range, 2-7 mm).
RESULTS: There were 2 thromboembolic procedural complications without clinical sequelae and no ruptures. The overall permanent procedural complication rate was 0% (0 of 40; 97.5% CI, 0%-10.4%). Imaging follow-up at 3 months was available in 33 patients with 39 aneurysms (97.5% of 40 eligible aneurysms). In 1 aneurysm, the detached WEB was undersized and the remnant was additionally treated with coils after 1 week. This same aneurysm reopened at 3 months and was again treated with a second WEB. One other aneurysm showed persistent WEB filling at 3 months. Complete occlusion was achieved in 28 of 39 aneurysms (72%), and 9 aneurysms (23%) showed a neck remnant.
CONCLUSIONS: The WEB 17 is safe and effective for both ruptured and unruptured aneurysms. The WEB 17 is a valuable addition to the existing WEB size range, especially for very small aneurysms.
© 2018 by American Journal of Neuroradiology.

Entities:  

Mesh:

Year:  2018        PMID: 29567650     DOI: 10.3174/ajnr.A5608

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  15 in total

1.  Two-Center Experience in the Endovascular Treatment of Intracranial Aneurysms Using the Woven EndoBridge 17 Device Including Midterm Follow-Up Results: A Retrospective Analysis.

Authors:  C Maurer; I König; A Berlis; W Weber; S Fischer
Journal:  AJNR Am J Neuroradiol       Date:  2019-09       Impact factor: 3.825

2.  Low-Profile Intra-Aneurysmal Flow Disruptor WEB 17 versus WEB Predecessor Systems for Treatment of Small Intracranial Aneurysms: Comparative Analysis of Procedural Safety and Feasibility.

Authors:  L Goertz; T Liebig; E Siebert; M Herzberg; L Pennig; M Schlamann; J Borggrefe; B Krischek; F Dorn; C Kabbasch
Journal:  AJNR Am J Neuroradiol       Date:  2019-09-05       Impact factor: 3.825

3.  Transradial Woven EndoBridge device to treat a ruptured basilar tip aneurysm under conscious sedation.

Authors:  P Bhogal; N Chan; Hld Makalanda; K Wong; J Noblet
Journal:  Interv Neuroradiol       Date:  2020-05-22       Impact factor: 1.610

4.  Shape Modification is Common in Woven EndoBridge-Treated Intracranial Aneurysms: A Longitudinal Quantitative Analysis Study.

Authors:  J Rosskopf; M Braun; J Dreyhaupt; M Beer; B L Schmitz; Y Ozpeynirci
Journal:  AJNR Am J Neuroradiol       Date:  2020-07-30       Impact factor: 3.825

5.  The Woven EndoBridge (WEB) as primary treatment for unruptured intracranial aneurysms.

Authors:  Sanne Bt van Rooij; Willem Jan van Rooij; Jo P Peluso; Menno Sluzewski
Journal:  Interv Neuroradiol       Date:  2018-05-16       Impact factor: 1.610

6.  Mid-term 3T MRA follow-up of intracranial aneurysms treated with the Woven EndoBridge.

Authors:  Sbt van Rooij; J P Peluso; M Sluzewski; H G Kortman; I Boukrab; W J van Rooij
Journal:  Interv Neuroradiol       Date:  2018-07-12       Impact factor: 1.610

7.  A comparison between the CS-TOF and the CTA/DSA for WEB device management.

Authors:  Oktay Algin; Gokhan Yuce; Ural Koc; Gıyas Ayberk
Journal:  Interv Neuroradiol       Date:  2021-05-06       Impact factor: 1.610

8.  Widening the Indications for Intrasaccular Flow Disruption: WEB 17 in the Treatment of Aneurysm Locations Different from Those in the Good Clinical Practice Trials.

Authors:  S Zimmer; V Maus; C Maurer; A Berlis; W Weber; S Fischer
Journal:  AJNR Am J Neuroradiol       Date:  2021-01-28       Impact factor: 3.825

9.  Safety and feasibility of the Woven EndoBridge device deployment with monitored anesthesia care.

Authors:  Daizo Ishii; Luyuan Li; Mario Zanaty; Jorge A Roa; Lauren Allan; Edgar A Samaniego; David M Hasan
Journal:  Interv Neuroradiol       Date:  2020-06-17       Impact factor: 1.610

10.  Different Rescue Approaches of Migrated Woven Endobridge (WEB) Devices: an Animal Study.

Authors:  Andreas Simgen; Michael Kettner; Philipp Dietrich; Toshiki Tomori; Ruben Mühl-Benninghaus; Pervinder Bhogal; Matthias W Laschke; Michael D Menger; Wolfgang Reith; Umut Yilmaz
Journal:  Clin Neuroradiol       Date:  2020-03-12       Impact factor: 3.649

View more