Literature DB >> 29566542

Comparative evaluation of Scheimpflug tomography parameters between thin non-keratoconic, subclinical keratoconic, and mild keratoconic corneas.

Samira Huseynli1, José Salgado-Borges2, Jorge L Alio3.   

Abstract

PURPOSE: To evaluate and compare the topographic and topometric parameters, thickness profile data, and data from enhanced elevation maps of thin non-keratoconic, subclinical keratoconic, and mild keratoconic corneas with the Pentacam Scheimpflug corneal tomography and to study the usefulness of different parameters to differentiate keratoconus from topographically normal thin corneas.
METHODS: The study included 30 eyes with subclinical keratoconus, 30 eyes with mild-stage keratoconus, and 54 healthy eyes with minimal pachymetry ≤500 µm, with a mean age of 21.19 ± 2.97, 21.75 ± 1.93, and 21.5 ± 2.95 years, respectively. The area under the receiver operating characteristic curves was used to analyze the diagnostic significance of the Pentacam parameters.
RESULTS: The anterior and posterior corneal elevations, pachymetric progression, the percentage of thickness increase measurements, overall D value, and topometric indices were statistically significantly higher in subclinical and mild keratoconic corneas than in normal eyes with thin cornea (p < 0.05). All these parameters had sufficient strength (area under the receiver operating characteristic curves >0.90) to differentiate clinical keratoconus. Posterior elevation showed the excellent area under the receiver operating characteristic curves with 100% sensitivity and 100% specificity for this purpose. However, among all parameters studied, the anterior elevation (0.935) showed the excellent area under the receiver operating characteristic curves to differentiate subclinical keratoconus, followed by posterior elevation (0.897), index of height decentration (0.887), and D value (0.882).
CONCLUSION: The parameters derived from the Scheimpflug device, such as corneal elevations and overall D value, can effectively differentiate subclinical and clinical keratoconus from non-keratoconic thin cornea eyes. However, the specificity levels of these parameters were relatively limited in the diagnosis of subclinical keratoconus.

Entities:  

Keywords:  Keratoconus; Pentacam topography; Scheimpflug tomography; corneal pachymetry; corneal topography; post LASIK ectasia; subclinical keratoconus

Mesh:

Year:  2018        PMID: 29566542     DOI: 10.1177/1120672118760146

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  12 in total

1.  Evaluation of topographic, tomographic, topometric, densitometric, and aberrometric features of cornea with pentacam HR system in subclinical keratoconus.

Authors:  Haci Hasan Ozkan; Mustafa Koc; Hasan Kiziltoprak; Kemal Tekin; Emre Aydemir
Journal:  Int Ophthalmol       Date:  2021-03-27       Impact factor: 2.031

2.  Corneal densitometry in bilateral keratoconus patients with unilateral corneal Vogt's striae: a contralateral eye study.

Authors:  Shengsheng Wei; Jing Li; Yong Li; Yaohua Zhang; Yan Cai; Jing Du; Jianguo Liu; Yan Wang
Journal:  Int Ophthalmol       Date:  2022-09-24       Impact factor: 2.029

3.  Anterior pituitary, sex hormones, and keratoconus: Beyond traditional targets.

Authors:  Dimitrios Karamichos; Paulina Escandon; Brenda Vasini; Sarah E Nicholas; Lyly Van; Deanna H Dang; Rebecca L Cunningham; Kamran M Riaz
Journal:  Prog Retin Eye Res       Date:  2021-11-02       Impact factor: 19.704

4.  Diagnostic Sensitivity of Different Reference Bodies When Using Scheimpflug Tomography in a Myopic Population with Keratoconus.

Authors:  Daniel Garcerant; Ignacio Jiménez-Alfaro; Nicolás Alejandre
Journal:  J Ophthalmol       Date:  2019-07-18       Impact factor: 1.909

5.  Effect of Down syndrome and keratoconus on corneal density and volume: a triple comparative study.

Authors:  Soheila Asgari; Mohammadreza Aghamirsalim; Shiva Mehravaran; Hassan Hashemi
Journal:  Sci Rep       Date:  2020-06-04       Impact factor: 4.379

6.  A hospital-based study on clinical data, demographic data and visual function of keratoconus patients in Central China.

Authors:  Kaili Yang; Liyan Xu; Qi Fan; Yuwei Gu; Bo Zhang; Feiying Meng; Dongqing Zhao; Chenjiu Pang; Shengwei Ren
Journal:  Sci Rep       Date:  2021-04-06       Impact factor: 4.379

7.  Revisiting the Robustness of Pentacam HR Indices Against Soft Contact Lens Wear.

Authors:  Rania Serag Elkitkat; Tamer Abdelfattah Badran; Weam Mohamed Ebeid
Journal:  Clin Ophthalmol       Date:  2021-04-15

8.  Assessment of the Association between In Vivo Corneal Morphogeometrical Changes and Keratoconus Eyes with Severe Visual Limitation.

Authors:  J S Velázquez; F Cavas; J Alió Del Barrio; D G Fernández-Pacheco; J Alió
Journal:  J Ophthalmol       Date:  2019-09-22       Impact factor: 1.909

9.  Assessment of Corneal Pachymetry Distribution and Morphologic Changes in Subclinical Keratoconus with Normal Biomechanics.

Authors:  Peng Song; Kaili Yang; Pei Li; Yu Liu; Dengfeng Liang; Shengwei Ren; Qingyan Zeng
Journal:  Biomed Res Int       Date:  2019-11-19       Impact factor: 3.411

10.  EMKLAS: A New Automatic Scoring System for Early and Mild Keratoconus Detection.

Authors:  Jose S Velázquez-Blázquez; José M Bolarín; Francisco Cavas-Martínez; Jorge L Alió
Journal:  Transl Vis Sci Technol       Date:  2020-05-27       Impact factor: 3.283

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.