Dependency of image quality on acquisition protocol and image processing in chest tomosynthesis-a visual grading study based on clinical data.

Masoud Jadidi1, Magnus Båth2,3, Sven Nyrén4,5.   

Abstract

OBJECTIVE: To compare the quality of images obtained with two different protocols with different acquisition time and the influence from image post processing in a chest digital tomosynthesis (DTS) system.
METHODS: 20 patients with suspected lung cancer were imaged with a chest X-ray equipment with tomosynthesis option. Two examination protocols with different acquisition times (6.3 and 12 s) were performed on each patient. Both protocols were presented with two different image post-processing (standard DTS processing and more advanced processing optimised for chest radiography). Thus, 4 series from each patient, altogether 80 series, were presented anonymously and in a random order. Five observers rated the quality of the reconstructed section images according to predefined quality criteria in three different classes. Visual grading characteristics (VGC) was used to analyse the data and the area under the VGC curve (AUCVGC) was used as figure-of-merit. The 12 s protocol and the standard DTS processing were used as references in the analyses.
RESULTS: The protocol with 6.3 s acquisition time had a statistically significant advantage over the vendor-recommended protocol with 12 s acquisition time for the classes of criteria, Demarcation (AUCVGC = 0.56, p = 0.009) and Disturbance (AUCVGC = 0.58, p < 0.001). A similar value of AUCVGC was found also for the class Structure (definition of bone structures in the spine) (0.56) but it could not be statistically separated from 0.5 (p = 0.21). For the image processing, the VGC analysis showed a small but statistically significant advantage for the standard DTS processing over the more advanced processing for the classes of criteria Demarcation (AUCVGC = 0.45, p = 0.017) and Disturbance (AUCVGC = 0.43, p = 0.005). A similar value of AUCVGC was found also for the class Structure (0.46), but it could not be statistically separated from 0.5 (p = 0.31).
CONCLUSION: The study indicates that the protocol with 6.3 s acquisition time yields slightly better image quality than the vender-recommended protocol with acquisition time 12 s for several anatomical structures. Furthermore, the standard gradation processing  (the vendor-recommended post-processing for DTS), yields to some extent advantage over the gradation processing/multiobjective frequency processing/flexible noise control processing in terms of image quality for all classes of criteria. Advances in knowledge: The study proves that the image quality may be strongly affected by the selection of DTS protocol and that the vendor-recommended protocol may not always be the optimal choice.

Entities:  

Mesh:

Year:  2018        PMID: 29565673      PMCID: PMC6221780          DOI: 10.1259/bjr.20170683

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  34 in total

1.  When does a radiologist's recommendation for follow-up result in high-cost imaging?

Authors:  Susanna I Lee; Arun Krishnaraj; Manjil Chatterji; Keith J Dreyer; James H Thrall; Peter F Hahn
Journal:  Radiology       Date:  2011-11-14       Impact factor: 11.105

2.  A software tool for increased efficiency in observer performance studies in radiology.

Authors:  Sara Börjesson; Markus Håkansson; Magnus Båth; Susanne Kheddache; Sune Svensson; Anders Tingberg; Anna Grahn; Mark Ruschin; Bengt Hemdal; Sören Mattsson; Lars Gunnar Månsson
Journal:  Radiat Prot Dosimetry       Date:  2005       Impact factor: 0.972

3.  Learning aspects and potential pitfalls regarding detection of pulmonary nodules in chest tomosynthesis and proposed related quality criteria.

Authors:  Sara Asplund; Ase A Johnsson; Jenny Vikgren; Angelica Svalkvist; Marianne Boijsen; Valeria Fisichella; Agneta Flinck; Asa Wiksell; Jonas Ivarsson; Hans Rystedt; Lars Gunnar Månsson; Susanne Kheddache; Magnus Båth
Journal:  Acta Radiol       Date:  2011-04-06       Impact factor: 1.990

4.  Monte Carlo simulations of the dosimetry of chest tomosynthesis.

Authors:  Angelica Svalkvist; Lars Gunnar Månsson; Magnus Båth
Journal:  Radiat Prot Dosimetry       Date:  2010-03-03       Impact factor: 0.972

5.  VIEWDEX: an efficient and easy-to-use software for observer performance studies.

Authors:  Markus Håkansson; Sune Svensson; Sara Zachrisson; Angelica Svalkvist; Magnus Båth; Lars Gunnar Månsson
Journal:  Radiat Prot Dosimetry       Date:  2010-03-03       Impact factor: 0.972

6.  THE VALIDITY OF USING ROC SOFTWARE FOR ANALYSING VISUAL GRADING CHARACTERISTICS DATA: AN INVESTIGATION BASED ON THE NOVEL SOFTWARE VGC ANALYZER.

Authors:  Jonny Hansson; Lars Gunnar Månsson; Magnus Båth
Journal:  Radiat Prot Dosimetry       Date:  2016-03-14       Impact factor: 0.972

7.  Multi-Institutional Evaluation of Digital Tomosynthesis, Dual-Energy Radiography, and Conventional Chest Radiography for the Detection and Management of Pulmonary Nodules.

Authors:  James T Dobbins; H Page McAdams; John M Sabol; Dev P Chakraborty; Ella A Kazerooni; Gautham P Reddy; Jenny Vikgren; Magnus Båth
Journal:  Radiology       Date:  2016-07-19       Impact factor: 11.105

8.  Visual grading characteristics (VGC) analysis of diagnostic image quality for high resolution 3 Tesla MRI volumetry of the olfactory bulb.

Authors:  Hartmut Peter Burmeister; Pascal Andreas Thomas Baltzer; Constanze Möslein; Thomas Bitter; Hilmar Gudziol; Matthias Dietzel; Orlando Guntinas-Lichius; Werner Alois Kaiser
Journal:  Acad Radiol       Date:  2011-03-02       Impact factor: 3.173

9.  Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases.

Authors:  Jenny Vikgren; Sara Zachrisson; Angelica Svalkvist; Ase A Johnsson; Marianne Boijsen; Agneta Flinck; Susanne Kheddache; Magnus Båth
Journal:  Radiology       Date:  2008-10-10       Impact factor: 11.105

10.  VISIBILITY OF STRUCTURES OF RELEVANCE FOR PATIENTS WITH CYSTIC FIBROSIS IN CHEST TOMOSYNTHESIS: INFLUENCE OF ANATOMICAL LOCATION AND OBSERVER EXPERIENCE.

Authors:  Carin Meltzer; Magnus Båth; Susanne Kheddache; Helga Ásgeirsdóttir; Marita Gilljam; Åse Allansdotter Johnsson
Journal:  Radiat Prot Dosimetry       Date:  2016-02-03       Impact factor: 0.972

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.