Response to letter to the editor on "Early intraprosthetic dislocation in dual-mobility implants: a systematic review".

Ivan De Martino1,2, Rocco D'Apolito2, Bradford S Waddell2, Alexander S McLawhorn1,2, Peter K Sculco1,2, Thomas P Sculco1,2.   

Abstract

Entities:  

Year:  2017        PMID: 29560410      PMCID: PMC5859558          DOI: 10.1016/j.artd.2017.11.005

Source DB:  PubMed          Journal:  Arthroplast Today        ISSN: 2352-3441


× No keyword cloud information.
In reply: We thank the Editor-in-Chief for the opportunity to respond to the Letter to the Editor by (Domenico et al [1]). The following are the responses to the main queries in the letter. Intraprosthetic dislocation (IPD) is a unique failure mechanism linked to dual-mobility (DM)-bearing designs and may occur any time after the index procedure. IPDs were described and classified in the European literature as a relatively late dislocation with a mean time to failure of 8-11 years after surgery [1], [2], [3], [4], [5] with conventional polyethylene (PE) liners. However, early IPDs have been reportedly affecting contemporary designs. The aim of our systematic review was to analyze the risk factors of early IPD in primary and revision total hip arthroplasty with contemporary DM designs [6]. The etiology of late IPD is known and already reported [1], [2], [3], [4], [5], [7] and therefore was not discussed. Speculation exists regarding the implant-related risk factors for early IPD, including pairing of femoral heads and PE liners from different manufacturers, 22.2 mm femoral heads, and skirted femoral heads [8], [9], [10]. We did not mention these as risk factors for early IPD. Instead we used the findings of our literature review to make some general consideration about early IPD and to clarify some common beliefs. From the available literature that was reviewed, there were no cases of early IPD occurring in patients with a femoral head smaller than 28 mm or in patients in which the DM component was used in conjunction with a skirted femoral head. Mixing DM components with different manufacturer components is an off-label practice and unsupported by both the US Food and Drug Administration and manufacturers, but it is commonly performed by surgeons to reduce complications associated with removal of well-fixed components. According to our findings, of the 19 reported cases only 6 reported cases (32%) of early IPD occurred in patients with a mismatch between femoral head and PE liner manufacturers, whereas 9 cases (47%) occurred in patients with no mismatch and in 4 cases (21%) was not specified. We did not make any statement about the mismatch as a risk factor [6]. From isolated case reports, it is difficult to make conclusions with any great confidence regarding the association between DM implant features and the risk of early IPD because denominator values for each feature are unknown. The only statement that we made was the high likelihood of iatrogenic etiology, whereby dissociation of the head and liner occurs during a closed reduction attempt of a large articulation dislocation. This mechanism accounted for the 79% (15 of 19) of the early IPD cases. The assumption that early IPD can be considered as a mechanical failure of the retentive rim is not supported from our data. Only 4 reported cases (21%) had no history of previous attempted closed reduction. Among them, the IPDs were due to PE wear caused by femoral neck impingement [10], poor impaction of the PE insert over the femoral head [11], vertical cup placement (abduction angle 67°) [12]. In one case was not clarified [13]. For this reason, it is very difficult to support the author's assumption due to the absence of evidence. We acknowledge that head diameter and jump distance are reduced in modular DM cups compared with the monoblock version with the same outer diameter. However, since the dislocation occurred equally in monoblock and modular DM cups, we did not make any statement about it. According to our data, in the setting of large articulation dislocations, precautions during closed reduction should be taken to prevent iatrogenic IPD [6]. We hope that these responses are informative, and we appreciate the writers' queries concerning the article.
  13 in total

1.  Fixation failures of dual mobility cups: a mid-term study of 2601 hip replacements.

Authors:  Philippe Massin; Vincent Orain; Rémi Philippot; Frederic Farizon; Michel Henry Fessy
Journal:  Clin Orthop Relat Res       Date:  2011-12-13       Impact factor: 4.176

2.  [Survival of cementless dual mobility sockets: ten-year follow-up].

Authors:  R Philippot; P Adam; F Farizon; M H Fessy; G Bousquet
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2006-06

3.  Severe metallosis owing to intraprosthetic dislocation in a failed dual-mobility cup primary total hip arthroplasty.

Authors:  Riazuddin Mohammed; Peter Cnudde
Journal:  J Arthroplasty       Date:  2011-07-12       Impact factor: 4.757

4.  Intraprosthetic dislocation of a contemporary dual-mobility design used during conversion THA.

Authors:  Andrew N Odland; Rafael J Sierra
Journal:  Orthopedics       Date:  2014-12       Impact factor: 1.390

Review 5.  Dislocation following total hip arthroplasty using dual mobility acetabular components: a systematic review.

Authors:  I De Martino; R D'Apolito; V G Soranoglou; L A Poultsides; P K Sculco; T P Sculco
Journal:  Bone Joint J       Date:  2017-01       Impact factor: 5.082

6.  Intraprosthetic dislocation: a specific complication of the dual-mobility system.

Authors:  Remi Philippot; Bertrand Boyer; Frederic Farizon
Journal:  Clin Orthop Relat Res       Date:  2012-10-10       Impact factor: 4.176

7.  Results with a cementless alumina-coated cup with dual mobility. A twelve-year follow-up study.

Authors:  F Farizon; R de Lavison; J J Azoulai; G Bousquet
Journal:  Int Orthop       Date:  1998       Impact factor: 3.075

8.  Salvage of Monoblock Metal-on-Metal Acetabular Components Using a Dual-Mobility Bearing.

Authors:  Darren R Plummer; Herman G Botero; Keith R Berend; James W Pritchett; Adolph V Lombardi; Craig J Della Valle
Journal:  J Arthroplasty       Date:  2015-08-29       Impact factor: 4.757

9.  [Intra-prosthetic dislocation of the Bousquet dual mobility socket].

Authors:  F Lecuire; I Benareau; J Rubini; M Basso
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2004-05

10.  Early intraprosthetic dislocation in dual-mobility implants: a systematic review.

Authors:  Ivan De Martino; Rocco D'Apolito; Bradford S Waddell; Alexander S McLawhorn; Peter K Sculco; Thomas P Sculco
Journal:  Arthroplast Today       Date:  2017-02-05