Literature DB >> 29516107

[Reversed total shoulder arthroplasty in rotator cuff defect arthropathy].

T Patzer1.   

Abstract

BACKGROUND: In a progredient rotator cuff tear with tendon retraction, fatty infiltration and atrophy of rotator cuff muscles the humerus cannot be centered and stabilized sufficiently in the glenohumeral joint. This leads to rotator cuff defect arthropathy as an eccentric osteoarthritis with acetabularization and wear of the acromion, as well as of the glenoid. INDICATION: A painful pseudoparalysis of the shoulder indicates the implantation of a reversed total shoulder arthroplasty (rTSA) to reduce pain and restore active motion. The rTSA improves the motoric function of the deltoid muscle by medialization and caudalization of the center of rotation via an optimized lever arm and is also indicated in cranio-caudally centered osteoarthritis with static posterior humeral decentration due to a bi-concavely eroded glenoid. THERAPY: Currently, humeral anatomical resection with an inclination of 135° and a humeral retrotorsion of 20-40°, in rTSA in contrast to 155° inclination, has been shown to lead to better glenohumeral motion without loss of stability. Additionally, a reduced glenohumeral offset should be restored by especially bony lateral augmentation of the glenoid. In a pre-operatively positive lag sign for external rotation caused by a rupture of the infraspinatus/teres minor tendon, a lateral latissimus/teres major muscle tendon transfer in rTSA can optimize active external rotation. The tendon of the subscapularis muscle should be re-fixated in the deltopectoral approach for rTSA whenever possible for better anterior stability of the glenohumeral joint. Larger diameters of the glenospheres have been shown to have more stability and better motion. Humeral metaphyseal metal liners with corresponding polyethylene glenospheres can avoid osteolysis of the inferior scapular neck caused by polyethylene debris due to impingement of the humeral liner at the scapular neck.

Entities:  

Keywords:  Artificial shoulder joint; Osteoarthrosis; Rotator cuff tear arthropathy; Rupture; Tendon transfer

Mesh:

Year:  2018        PMID: 29516107     DOI: 10.1007/s00132-018-3543-6

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  37 in total

Review 1.  Problems, complications, reoperations, and revisions in reverse total shoulder arthroplasty: a systematic review.

Authors:  Matthias A Zumstein; Miguel Pinedo; Jason Old; Pascal Boileau
Journal:  J Shoulder Elbow Surg       Date:  2011-01       Impact factor: 3.019

2.  Neer Award 2005: The Grammont reverse shoulder prosthesis: results in cuff tear arthritis, fracture sequelae, and revision arthroplasty.

Authors:  Pascal Boileau; Duncan Watkinson; Armodios M Hatzidakis; Istvan Hovorka
Journal:  J Shoulder Elbow Surg       Date:  2006 Sep-Oct       Impact factor: 3.019

3.  Angled BIO-RSA (bony-increased offset-reverse shoulder arthroplasty): a solution for the management of glenoid bone loss and erosion.

Authors:  Pascal Boileau; Nicolas Morin-Salvo; Marc-Olivier Gauci; Brian L Seeto; Peter N Chalmers; Nicolas Holzer; Gilles Walch
Journal:  J Shoulder Elbow Surg       Date:  2017-07-20       Impact factor: 3.019

4.  Comparison of reverse total shoulder arthroplasty outcomes with and without subscapularis repair.

Authors:  Richard J Friedman; Pierre-Henri Flurin; Thomas W Wright; Joseph D Zuckerman; Christopher P Roche
Journal:  J Shoulder Elbow Surg       Date:  2016-10-27       Impact factor: 3.019

5.  Scapular notching in reverse shoulder arthroplasty: is it important to avoid it and how?

Authors:  Christophe Lévigne; Jérome Garret; Pascal Boileau; Ghassan Alami; Luc Favard; Gilles Walch
Journal:  Clin Orthop Relat Res       Date:  2011-09       Impact factor: 4.176

6.  Glenosphere size in reverse shoulder arthroplasty: is larger better for external rotation and abduction strength?

Authors:  Andreas M Müller; Marian Born; Christian Jung; Matthias Flury; Christoph Kolling; Hans-Kaspar Schwyzer; Laurent Audigé
Journal:  J Shoulder Elbow Surg       Date:  2017-07-24       Impact factor: 3.019

7.  Sonographic assessment of the subscapularis after reverse shoulder arthroplasty: impact of tendon integrity on shoulder function.

Authors:  Nicolas J Dedy; Conor J Gouk; Fraser J Taylor; Michael Thomas; S L Ezekiel Tan
Journal:  J Shoulder Elbow Surg       Date:  2018-02-12       Impact factor: 3.019

8.  Reversed shoulder arthroplasty in cuff tear arthritis, fracture sequelae, and revision arthroplasty.

Authors:  Annika Stechel; Uwe Fuhrmann; Lars Irlenbusch; Olaf Rott; Ulrich Irlenbusch
Journal:  Acta Orthop       Date:  2010-06       Impact factor: 3.717

9.  Reverse total shoulder arthroplasty for primary glenohumeral osteoarthritis in patients with a biconcave glenoid.

Authors:  Naoko Mizuno; Patrick J Denard; Patric Raiss; Gilles Walch
Journal:  J Bone Joint Surg Am       Date:  2013-07-17       Impact factor: 5.284

10.  Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff. Results of a multicentre study of 80 shoulders.

Authors:  F Sirveaux; L Favard; D Oudet; D Huquet; G Walch; D Molé
Journal:  J Bone Joint Surg Br       Date:  2004-04
View more
  2 in total

1.  [Shoulder arthroplasty].

Authors:  Dennis Wassenaar; André Busch; Alexander Wegner; Marcus Jäger
Journal:  Orthopade       Date:  2021-02-04       Impact factor: 1.087

2.  Substantial clinical benefit, responsiveness, and sensitivity to change of three common outcome measures following shoulder arthroplasty.

Authors:  Helen Razmjou; Leila Rahnama; Richard Holtby; Darren Drosdowech; Robin Richards
Journal:  SAGE Open Med       Date:  2020-07-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.