| Literature DB >> 29506509 |
Zhihua Zhang1,2,3, Minwen Zhou1,2,3, Kun Liu1,2,3, Bijun Zhu1,2,3, Haiyun Liu4,5,6, Xiaodong Sun1,2,3, Xun Xu1,2,3.
Abstract
BACKGROUND: More and more concerns have been arisen about the ability of new medical graduates to meet the demands of today's practice environment. In this study, we wanted to develop a valid, reliable and standardized assessment tool for evaluating the basic microsurgical skills of residents in a microsurgery laboratory, to get them well prepared before entering the surgical realm of ophthalmology.Entities:
Keywords: Assessment scale; Cornea suturing; Medical education; Microsurgical skill
Mesh:
Year: 2018 PMID: 29506509 PMCID: PMC5838947 DOI: 10.1186/s12886-018-0736-z
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Fig. 1Illustrations of fresh pig eye for microscopic suturing in wet lab. a. Fresh pig eye before incision was made; b. “L” shaped incision was made on pig eye
Fig. 2Survey sent to experts to determine the face and content validity of the assessment scale
Results of the Content and Face Validity Survey
| Are those items appropriate? | Percentage |
|---|---|
| Microscope use | 21/23 (91%) |
| Instrument handling | 21/23 (91%) |
| Hand coordination | 23/23 (100%) |
| Suturing order | 22/23 (96%) |
| Suturing interval | 23/23 (100%) |
| Suturing width | 23/23 (100%) |
| Suturing depth | 23/23(100%) |
| Knotting | 20/23 (87%) |
| Wound closure and anterior chamber formation | 23/23 (100%) |
| Abnormal events management | 18/23 (78%) |
| Overall performance | 23/23(100%) |
Reported as the fraction (percent) of respondents answering “Yes” to the question
Assessment Scale of Corneal Rupture Suturing
| DATE _____ | 1 | 2 | 3 | 4 | 5 | Score |
|---|---|---|---|---|---|---|
| Preoperative preparation | Failed to wear hat, mask and gloves | Failed to wear two of the three | Failed to wear one of the three | Wearing hat, mask and gloves correctly | Wearing hat, mask and gloves smoothly | |
| Microscope use | Out of center and focus constantly | Out of center and focus frequently | Out of center and focus occasionally | Stay in center and focus constantly | Fluid moves with microscope | |
| Instrument handling | Constantly makes tentative and awkward moves with instruments by impropriate use | Frequently makes tentative and awkward moves with instruments | Fair use of instruments but occasionally stiff or awkward | Competent use of instruments | Fluid moves with instruments | |
| Hands coordination | Severely hands tremor and constantly instruments collision | Hands tremor and frequently instruments collision | Mild hands tremor and occasionally instrument collision | No hands tremor and instrument collision | Steady hands and perfect hands coordination | |
| Suturing | Sutures are done in an awkward, slow fashion with much difficulty. Bent needles | Sutures are done with difficulty | Sutures are done with little difficulty | Sutures are done properly. Loads needle 1/2 to 2/3 from tip. Approaches eye with flat portion of needle. Needle enters perpendicular to cornea | Smooth and perfect suturing. Always loads needle 1/2 to 2/3 from tip. Always approaches eye with flat portion of needle. Needle enters perpendicular to cornea | |
| Suturing order | Suture the rupture randomly | Suture the rupture in one direction | Selectively suture the rupture. Close the center first | Selectively suture the rupture. Close the angle first | Selectively suture the rupture. Surgical exploration of the limbus. Close the limbus first, then the angle | |
| Stitches interval | Awfully uneven | Uneven | Almost even | Even | Perfectly even, around 2 mm | |
| Stitches width | Awfully uneven | Uneven | Almost even | Even | Perfectly even, around 2 mm | |
| Stitches depth | Awfully uneven | Uneven | Almost even | Even | Perfectly even, around 2/3 of the cornea thickness | |
| Knotting | Knots are placed in an awkward, slow fashion with much difficulty | Knots are placed with difficulty | Knots are placed with little difficulty | Knots are placed properly with seldom breaking sutures | Knots are placed perfectly with no breaking sutures | |
| Knots tightness | Suture tightness is awfully uneven. Sutures are too tight or loose | Suture tightness is uneven. Sutures are tight or loose | Suture tightness is almost even. Sutures are a little bit tight or loose | Suture tightness is proper and even | Suture tightness is perfectly even. Sutures are placed tight enough to maintain the wound closed, but not too tight as to induce astigmatism | |
| Knots rotation | No suture rotation at all | Most of the sutures are not rotated | Parts of the sutures are not rotated | Most of the sutures are rotated | Complete suture rotation. No knots exposure | |
| Wound closure and anterior chamber formation | No wound closure and no anterior chamber formation | Part of wound closure and no anterior chamber formation | Questionable wound closure and anterior chamber formation | Complete wound closure and anterior chamber formation | Neat and watertight wound closure. Perfect anterior chamber formation with no anterior synechia of iris | |
| Postoperative clean up | Failed to clean up the pig eyes. Failed to settle the microscope and instruments. Failed to take off the hat, mask and gloves properly | Failed to do two of the three things | Failed to do one of the three things | Complete all the three things | Throw the pig eye in the yellow bag. Settle the microscope and instruments. Take off the hat, mask and gloves correctly | |
| Overall performance | Unable to finish the operation independently | Hesitant, frequent starts and stops. Finish the operation with difficulty | Occasional starts and stops. Finish the operation within 20mins | Competent, finish the operation within 15mins | Confident and fluid, finish the operation within 10mins |
Interrater reliability of 23 observers for corneal rupture suturing assessing scale
| ICC | 95% CI | ||
|---|---|---|---|
| Lower bound | Upper bound | ||
| Preoperative preparation | 0.953*** | 0.888 | 0.989 |
| Microscope use | 0.976*** | 0.942 | 0.994 |
| Instrument handling | 0.940*** | 0.857 | 0.986 |
| Hand coordination | 0.963*** | 0.913 | 0.991 |
| Suturing | 0.866*** | 0.682 | 0.968 |
| Suturing order | 0.971*** | 0.932 | 0.993 |
| Suturing interval | 0.943*** | 0.863 | 0.986 |
| Suturing width | 0.939*** | 0.855 | 0.985 |
| Suturing depth | 0.860*** | 0.668 | 0.967 |
| Knotting | 0.922*** | 0.815 | 0.981 |
| Knots tightness | 0.886*** | 0.728 | 0.973 |
| Knots rotation | 0.913*** | 0.793 | 0.979 |
| Wound closure and anterior chamber formation | 0.892*** | 0.744 | 0.974 |
| Postoperative clean up | 0.920*** | 0.809 | 0.981 |
| Overall performance | 0.965*** | 0.917 | 0.992 |
| Total score | 0.959*** | 0.901 | 0.990 |
ICC intraclass correlation coefficient, CI confidential interval
***: P < 0.001
Intrarater reliability (repeatability) for corneal rupture suturing assessing scale
| Item | ICC | 95% CI | |
|---|---|---|---|
| Lower bound | Upper bound | ||
| Preoperative preparation | 0.907*** | 0.867 | 0.935 |
| Microscope use | 0.934*** | 0.906 | 0.954 |
| Instrument handling | 0.866*** | 0.811 | 0.906 |
| Hand coordination | 0.904*** | 0.863 | 0.933 |
| Suturing | 0.865*** | 0.810 | 0.905 |
| Suturing order | 0.954*** | 0.934 | 0.968 |
| Suturing interval | 0.919*** | 0.884 | 0.943 |
| Suturing width | 0.901*** | 0.860 | 0.931 |
| Suturing depth | 0.885*** | 0.837 | 0.920 |
| Knotting | 0.916*** | 0.880 | 0.941 |
| Knots tightness | 0.833*** | 0.767 | 0.822 |
| Knots rotation | 0.843*** | 0.779 | 0.889 |
| Wound closure and anterior chamber formation | 0.901*** | 0.859 | 0.931 |
| Postoperative clean up | 0.893*** | 0.848 | 0.925 |
| Overall performance | 0.940*** | 0.915 | 0.959 |
| Total score | 0.946*** | 0.922 | 0.962 |
ICC intraclass correlation coefficient, CI confidential interval
***: P < 0.001