Literature DB >> 28288454

Validation of the Nuclear Cataract Grading System BCN 10.

Rafael I Barraquer1, Laura Pinilla Cortés, Miriam J Allende, Gustavo A Montenegro, Bozidar Ivankovic, Justin Christopher D'Antin, Hernán Martínez Osorio, Ralph Michael.   

Abstract

PURPOSE: To evaluate a new nuclear cataract grading system which is intended as a surgical guidance system to predict lens hardness before cataract surgery.
METHODS: The new BCN 10 grading system consists of frontal and cross-sectional slit-lamp images of human eye lenses, ranging from a completely transparent lens nucleus to a totally black nuclear cataract. Validation was done with 9 observers for 110 cases. Two modalities were applied, and observers were asked to use only whole digits and then half digits for grading.
RESULTS: Repeatability with regard to test-retest differences showed a mean limit of agreement of 1.70 for whole digits and 1.32 for half digits. The absolute test-retest difference was close to zero for low as well high degrees of cataracts. Reliability for the entire group of 9 observers yielded an intraclass correlation coefficient which was within the same confidence interval, i.e., 0.991-0.995, for whole digits and half digits.
CONCLUSIONS: BCN 10 grading repeatability was not affected by the severity of the cataract. It showed very good repeatability. Repeatability was significantly higher when the observers used half digits compared to whole digits. Reliability was found to be very good as well, independently of the use of whole or half digits.
© 2017 The Author(s) Published by S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2017        PMID: 28288454     DOI: 10.1159/000456720

Source DB:  PubMed          Journal:  Ophthalmic Res        ISSN: 0030-3747            Impact factor:   2.892


  6 in total

1.  Pre-operative simulation of post-operative multifocal vision.

Authors:  Maria Vinas; Sara Aissati; Mercedes Romero; Clara Benedi-Garcia; Nuria Garzon; Francisco Poyales; Carlos Dorronsoro; Susana Marcos
Journal:  Biomed Opt Express       Date:  2019-10-21       Impact factor: 3.732

2.  Development of a new valid and reliable microsurgical skill assessment scale for ophthalmology residents.

Authors:  Zhihua Zhang; Minwen Zhou; Kun Liu; Bijun Zhu; Haiyun Liu; Xiaodong Sun; Xun Xu
Journal:  BMC Ophthalmol       Date:  2018-03-05       Impact factor: 2.209

3.  Deformations and Ruptures in Human Lenses With Cortical Cataract Subjected to Ex Vivo Simulated Accommodation.

Authors:  Ralph Michael; Justin Christopher D'Antin; Laura Pinilla Cortés; Harvey John Burd; Brian Sheil; Rafael I Barraquer
Journal:  Invest Ophthalmol Vis Sci       Date:  2021-01-04       Impact factor: 4.799

4.  Clinical Practice of Cataract Special Care Standards in Nonophthalmic Wards.

Authors:  Juan Yang; Lina Yang; Yawen Chen
Journal:  J Healthc Eng       Date:  2022-01-07       Impact factor: 2.682

5.  Correlation Between Degree of Lens Opacity and the Phacoemulsification Energy Parameters Using Different Imaging Methods in Age-Related Cataract.

Authors:  Li Feng; Fangkun Zhao; Xin Ke; Jiangyue Zhao; Mingyu Shi
Journal:  Transl Vis Sci Technol       Date:  2022-03-02       Impact factor: 3.283

6.  Estimation of intraocular lens position from full crystalline lens geometry: towards a new generation of intraocular lens power calculation formulas.

Authors:  Eduardo Martinez-Enriquez; Pablo Pérez-Merino; Sonia Durán-Poveda; Ignacio Jiménez-Alfaro; Susana Marcos
Journal:  Sci Rep       Date:  2018-06-29       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.