Literature DB >> 29472080

Patient-specific organ and effective dose estimates in pediatric oncology computed tomography.

Yiming Gao1, Brian Quinn2, Neeta Pandit-Taskar3, Gerald Behr4, Usman Mahmood5, Daniel Long6, X George Xu7, Jean St Germain8, Lawrence T Dauer9.   

Abstract

PURPOSE: Estimate organ and effective doses from computed tomography scans of pediatric oncologic patients using patient-specific information.
MATERIALS AND METHODS: With IRB approval patient-specific scan parameters and patient size obtained from DICOM images and vendor-provided dose monitoring application were obtained for a cross-sectional study of 1250 pediatric patients from 0 through 20 y-olds who underwent head, chest, abdomen-pelvis, or chest-abdomen-pelvis CT scans. Patients were categorized by age. Organ doses and effective doses were estimated using VirtualDose™ CT based on patient-specific information, tube current modulation (TCM), and age-specific realistic phantoms. CTDIvol, DLP, and dose results were compared with those reported in the literature.
RESULTS: CTDIvol and DLP varied widely as patient size varied. The 75th percentiles of CTDIvol and DLP were no greater than in the literature with the exception of head scans of 16-20 y-olds and of abdomen-pelvis scans of larger patients. Eye lens dose from a head scan was up to 69 mGy. Mean organ doses agreed with other studies at maximal difference of 38% for chest and 41% for abdomen-pelvis scans. Mean effective dose was generally higher for older patients. The highest effective doses were estimated for the 16-20 y-olds as: head 3.3 mSv, chest 4.1 mSv, abdomen-pelvis 10.0 mSv, chest-abdomen-pelvis 14.0 mSv.
CONCLUSION: Patient-specific organ and effective doses have been estimated for pediatric oncologic patients from <1 through 20 y-olds. The effect of TCM was successfully accounted for in the estimates. Output parameters varied with patient size. CTDIvol and DLP results are useful for future protocol optimization.
Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Computed tomography; Diagnostic reference level; Organ dose; Pediatric

Mesh:

Year:  2017        PMID: 29472080      PMCID: PMC5828028          DOI: 10.1016/j.ejmp.2017.12.013

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  35 in total

1.  Reduced frequency of sedation of young children with multisection helical CT.

Authors:  J N Pappas; L F Donnelly; D P Frush
Journal:  Radiology       Date:  2000-06       Impact factor: 11.105

2.  Radiation dose reduction to the breast in thoracic CT: comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current.

Authors:  Jia Wang; Xinhui Duan; Jodie A Christner; Shuai Leng; Lifeng Yu; Cynthia H McCollough
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

5.  New organ-based tube current modulation method to reduce the radiation dose during computed tomography of the head: evaluation of image quality and radiation dose to the eyes in the phantom study.

Authors:  Jung-Su Kim; Soon-Mu Kwon; Jung-Min Kim; Sang-Wook Yoon
Journal:  Radiol Med       Date:  2017-03-24       Impact factor: 3.469

6.  Dose reduction to anterior surfaces with organ-based tube-current modulation: evaluation of performance in a phantom study.

Authors:  Xinhui Duan; Jia Wang; Jodie A Christner; Shuai Leng; Katharine L Grant; Cynthia H McCollough
Journal:  AJR Am J Roentgenol       Date:  2011-09       Impact factor: 3.959

Review 7.  Comparison of organ dosimetry methods and effective dose calculation methods for paediatric CT.

Authors:  Z Brady; T M Cain; P N Johnston
Journal:  Australas Phys Eng Sci Med       Date:  2012-04-11       Impact factor: 1.430

8.  Managing patient dose in multi-detector computed tomography(MDCT). ICRP Publication 102.

Authors:  J Valentin
Journal:  Ann ICRP       Date:  2007

9.  Development of a method to estimate organ doses for pediatric CT examinations.

Authors:  Antonios E Papadakis; Kostas Perisinakis; John Damilakis
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

10.  The feasibility of a regional CTDIvol to estimate organ dose from tube current modulated CT exams.

Authors:  Maryam Khatonabadi; Hyun J Kim; Peiyun Lu; Kyle L McMillan; Chris H Cagnon; John J DeMarco; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

View more
  1 in total

1.  Patient-Specific Organ and Effective Dose Estimates in Adult Oncologic CT.

Authors:  Yiming Gao; Usman Mahmood; Tianyu Liu; Brian Quinn; Marc J Gollub; X George Xu; Lawrence T Dauer
Journal:  AJR Am J Roentgenol       Date:  2019-08-15       Impact factor: 3.959

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.