BACKGROUND: Intra-operative estimation of stem anteversion in total hip arthroplasty (THA) using postero-lateral approach is made by the surgeon's visual assessment, using the tibia as a guide, with the assumption that tibial axis is vertical to the trans-epicondylar axis. However, the accuracy of the intra-operative estimation has rarely been verified with postoperative CT-scans, with controversies regarding these measurements particularly in case of knee osteoarthritis. Therefore we performed a prospective study to: (1) determine the accuracy of the intra-operative measurement and (2) investigate factors affecting the discrepancy between the surgeon's estimation and the real stem anteversion. HYPOTHESIS: Intra-operative estimation of stem anteversion correlated with the real stem anteversion on CT-scan. PATIENTS AND METHODS: Sixty-seven THAs using cementless straight stems (65 patients) without ipsilateral total knee arthroplasty were prospectively evaluated to compare the intra-operative measurement of stem anteversion with the real stem anteversion on computed tomography (CT) scans. There were 33 men and 34 women with a mean age of 59.7years (range, 27-84years) at the time of surgery. Age, tibia plateau angle, native femoral anteversion, femoro-tibial angle, body mass index, operative site, gender, coronal and sagittal tilt of the stem, stem type, ipsilateral knee osteoarthritis, and preoperative diagnosis were analyzed to evaluate the factors affecting the discrepancy between the intra-operative and CT measurements.
RESULTS: The intra-operative estimation (mean, 21.5°±8.5°; range, 5.0°-39.0°) was greater than the CT measurement (mean, 19.5°±8.7°; range, 4.5°-38.5°) by 2.0°. The mean absolute value of discrepancy was 4.5°. The correlation coefficient between intra-operative and CT measurements was 0.837. The femoro-tibial angle was associated with the discrepancy between the two measurements. In the presence of genu varum deformity, the intra-operative measurement underestimated the stem anteversion. DISCUSSION: Although intra-operative estimation of stem anteversion was slightly greater than the real stem anteversion, there was an excellent correlation between the two. The femoro-tibial angle should be considered to optimize the stem anteversion during cementless THA using postero-lateral approach. LEVEL OF EVIDENCE: Level III, prospective case control study.
Copyright © 2018 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Anteversion; Cementless stem; Femoro-tibial angle; Intra-operative estimation; Postero-lateral approach; Total hip arthroplasty

Mesh:

Year:  2018        PMID: 29458202     DOI: 10.1016/j.otsr.2017.11.023

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  5 in total

1.  Distribution and outliers of anteversion of short-length cementless stem.

Authors:  Hong-Seok Kim; Young-Kyun Lee; Joo-Hyung Ha; Se Jin Park; Jung-Wee Park; Kyung-Hoi Koo
Journal:  Int Orthop       Date:  2021-11-20       Impact factor: 3.075

2.  Measurement of operative femoral anteversion during cementless total hip arthroplasty and influencing factors for using neck-adjustable femoral stem.

Authors:  Jingyang Sun; Bohan Zhang; Lei Geng; Qingyuan Zheng; Juncheng Li; Wenzhe Cao; Ming Ni; Guoqiang Zhang
Journal:  J Orthop Surg Res       Date:  2021-05-31       Impact factor: 2.359

3.  A simple angle-measuring instrument for measuring cemented stem anteversion during total hip arthroplasty.

Authors:  Ryo Mitsutake; Hiromasa Tanino; Yasuhiro Nishida; Masaru Higa; Hiroshi Ito
Journal:  BMC Musculoskelet Disord       Date:  2020-02-19       Impact factor: 2.362

4.  3D Printed Guides and Preoperative Planning for Uncemented Stem Anteversion Reconstruction during Hip Arthroplasty: A Pilot Study.

Authors:  Yingqi Zhang; Zhitao Rao; Jincheng Zhang; Shijie Li; Shimin Chang; Yeqing Sun
Journal:  Biomed Res Int       Date:  2021-02-19       Impact factor: 3.411

5.  Accuracy of intraoperative estimation of femoral stem anteversion in cementless total hip arthroplasty by using a digital protractor and a spirit level.

Authors:  Anuwat Pongkunakorn; Nawakun Phetpangnga; Narawit Kananai
Journal:  J Orthop Surg Res       Date:  2021-01-07       Impact factor: 2.359

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.