Literature DB >> 33681357

3D Printed Guides and Preoperative Planning for Uncemented Stem Anteversion Reconstruction during Hip Arthroplasty: A Pilot Study.

Yingqi Zhang1, Zhitao Rao1, Jincheng Zhang1, Shijie Li2, Shimin Chang2, Yeqing Sun1.   

Abstract

OBJECTIVE: To investigate if 3D printed guides and preoperative planning can accurately control femoral stem anteversion.
METHODS: A prospective comparative study was carried out from 2018 to 2020, including 53 patients who underwent hip arthroplasty for femoral neck fracture. The target rotation center of the femoral head is determined by three-dimensional planning. In group A, planning was made by 2D templates. In group B, preoperative 3D planning and 3D printed osteotomy/positioning guides were performed. After the operation, 3D model registration was performed to calculate the accuracy of anteversion restoration.
RESULTS: We screened 60 patients and randomized a total of 53 to 2 parallel study arms: 30 patients to the group A (traditional operation) and 23 patients to the group B (3D preoperative planning and 3D printed guide). There were no significant differences in demographic or perioperative data between study groups. The restoration accuracy of group A was 5.42° ± 3.65° and of group B was 2.32° ± 1.89°. The number and rate of abnormal cases was 15 (50%) and 2 (8.7%), respectively. Significant statistical differences were found in angle change, restoration accuracy, and number of abnormal cases.
CONCLUSION: Three-dimensional preoperative planning and 3D printed guides can improve the accuracy of the restoration of femoral anteversion during hip arthroplasty.
Copyright © 2021 Yingqi Zhang et al.

Entities:  

Mesh:

Year:  2021        PMID: 33681357      PMCID: PMC7910057          DOI: 10.1155/2021/6621882

Source DB:  PubMed          Journal:  Biomed Res Int            Impact factor:   3.411


  29 in total

1.  Combined anteversion technique for total hip arthroplasty.

Authors:  Lawrence D Dorr; Aamer Malik; Manish Dastane; Zhinian Wan
Journal:  Clin Orthop Relat Res       Date:  2008-11-01       Impact factor: 4.176

2.  Tailor-made Surgical Guide Reduces Incidence of Outliers of Cup Placement.

Authors:  Takehito Hananouchi; Masanobu Saito; Tsuyoshi Koyama; Nobuhiko Sugano; Hideki Yoshikawa
Journal:  Clin Orthop Relat Res       Date:  2009-07-24       Impact factor: 4.176

3.  A comparison of surgeon estimation and computed tomographic measurement of femoral component anteversion in cementless total hip arthroplasty.

Authors:  Lawrence D Dorr; Zhinian Wan; Aamer Malik; Jinjun Zhu; Manish Dastane; Prashant Deshmane
Journal:  J Bone Joint Surg Am       Date:  2009-11       Impact factor: 5.284

4.  Does total hip arthroplasty restore native hip anatomy? three-dimensional reconstruction analysis.

Authors:  Tsung-Yuan Tsai; Dimitris Dimitriou; Guoan Li; Young-Min Kwon
Journal:  Int Orthop       Date:  2014-06-26       Impact factor: 3.075

5.  Comparison of acetabular shell position using patient specific instruments vs. standard surgical instruments: a randomized clinical trial.

Authors:  Travis Small; Viktor Krebs; Robert Molloy; Jason Bryan; Alison K Klika; Wael K Barsoum
Journal:  J Arthroplasty       Date:  2013-10-16       Impact factor: 4.757

6.  Evaluation of a patient specific femoral alignment guide for hip resurfacing.

Authors:  Michael Olsen; Douglas D Naudie; Max R Edwards; Michael E Sellan; Richard W McCalden; Emil H Schemitsch
Journal:  J Arthroplasty       Date:  2013-09-12       Impact factor: 4.757

7.  Difference in Stem Alignment Between the Direct Anterior Approach and the Posterolateral Approach in Total Hip Arthroplasty.

Authors:  Hirohito Abe; Takashi Sakai; Masaki Takao; Takashi Nishii; Nobuo Nakamura; Nobuhiko Sugano
Journal:  J Arthroplasty       Date:  2015-04-24       Impact factor: 4.757

8.  CT-based Navigation System Using a Patient-Specific Instrument for Femoral Component Positioning: An Experimental in vitro Study with a Sawbone Model.

Authors:  Seongpung Lee; Jun Young Kim; Jaesung Hong; Seung Hoon Baek; Shin Yoon Kim
Journal:  Yonsei Med J       Date:  2018-08       Impact factor: 2.759

9.  A simple angle-measuring instrument for measuring cemented stem anteversion during total hip arthroplasty.

Authors:  Ryo Mitsutake; Hiromasa Tanino; Yasuhiro Nishida; Masaru Higa; Hiroshi Ito
Journal:  BMC Musculoskelet Disord       Date:  2020-02-19       Impact factor: 2.362

10.  A Comparative Study of Patients' Subjective Feelings Toward Total Hip Arthroplasty with Patient-Specific Instruments and Traditional Total Hip Arthroplasty.

Authors:  Qi-Qi Xing; Da Zhong; Yi-Xiao Pan; Sen-Bo An; Cheng-Gong Wang; Shi-Long Su; Long Wang; Yi-He Hu
Journal:  Orthop Surg       Date:  2020-02       Impact factor: 2.071

View more
  1 in total

Review 1.  Application of three-dimensional printing technology in peripheral hip diseases.

Authors:  Shuai Liang; Jia Xie; Fangyuan Wang; Juehua Jing; Jun Li
Journal:  Bioengineered       Date:  2021-12       Impact factor: 3.269

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.